Reliant EMC

EMCIS EMI Test Systems

EMCIS makes two EMI Test Systems;
ETS-10 Click here for detailed information
FTS-10 Click here for detailed information
 
EMCIS EMI Test System Summary:
 
ETS-10 EMI Test System
EMCIS ETS-10 EMI Test System
The ETS-10 EMI Test System from EMCIS included everything an engineer will need for Testing to CISPR 16 & MIL-STD-461E/F, all in one 19-inch rack.
This combined and integrated system allows engineers to solve EMI problems efficiently and economically.

The ETS-10 EMI Test System includes:
• Spectrum Analyzer
EMI Analyzer - EA-300 or EA-2100
Impedance Module - IMP-16
LISN - LNS-16N
Power Line Filter
Insulation Transformer
PC
 
Specifications
Standard Testing
CISPR 16 & MIL-STD-461E/F
Frequency Range
9kHz~30 MHz
Analysis
L1, L2, CM, DM
Power for EUT
DC~60Hz, 250Vmax
Power for System
AC240V 50/60Hz
Mechanism
19″ Rack
Dimension(mm)
W600  D750  H1400
 
Key Characteristics of ETS-10
  • • 9kHz ~ 30MHz frequency range.
  • • Noise analysis in CM & DM, satisfying MIL-25D-461 AND cispr16 standards.
  • • Theoretical Filter Design approach-extended applicable EMI filter components research-coil and capacitor.
  • • Dramatic time saving in EMI solution process(EMI debugging)
  • • Most suitable system configuration for R&D and Quality engineers.

 

System Configuration

EMCIS ETS-10 EMI Test System System Configuration

FTS-10 EMI Test System
Spectrum analyzers,Filter analyzer,Test table, etc, mounted on standard 19-inch rack has been systematized so that you can easily test the attenuation characteristics of EMI filter. FTS Series can be used for quality assurance,Design, production, QC, etc.

 

Specifications
Standard Testing
CISPR17, MIL-STD-220B
Frequency Range
9kHz~300MHz
Test & Analysis Selector
L1, L2, CM, DM
Power Rate for System
AC100~240V, 50/60Hz
Mechanism
19″ Rack
Dimensions (mm)
W600  D750  H1400
 
Components
• Spectrum Analyzer
• Filter Analyzer - FA-2100
• Test Table
• Transient Limiter
 
Key Characteristics of the FTS-10:
• Measure the noises, meet CISPR16, MIL-STD-220B standards
• 9kHz ~ 30MHz frequency range
• Measure and analyze noises in CM & DM and their insertion loss characteristics
• Applicable in EMI filter components research- coil and capacitor
• Dramatic time saving in EMI solution process (EMI debugging)
• Most suitable system configuration for R&D and quality engineers
 

EMCIS FTS-10 EMI Test System System Configuration


Associated Downloads
 


Request a Quote / Contact Us!
EMCIS - ElectroMagnetic Compatibility Instruments & Solution
 

EMCIS product Line