Reliant EMC

Surge (Hybrid) generators

Surge (Hybrid) Generators
Hilo-Test Surge (Hybrid) Generators
CE-Surge / CE Tester
Combination Wave Generator PG 7-250
PG 10-504 Combination Wave Generator
PG 12-804 Combination Wave Generator
PG 24-2k5 Surge Test Generator
CE-Tester 2
EMC 2015 Impulse Generator

 

Hilo-Test Surge (Hybrid) Generators
Surge pulses occur due to direct or indirect lightning strikes in a circuit or by switching transients caused by switching inductive loads or short circuits. This leads to currents or electromagnetic fields causing high voltage or current transients. Surge voltages and currents can reach several thousands of volts and thousands of amperes. The following HILO-TEST Surge generators simulate these disturbances for all the necessary levels in accordance with IEC / EN 61000-4-5 and IEC / EN 60060:
 

 

CE-Surge / CE Tester
CE Tester / CE Surge
 
Summary:
• Voltage: 5 kV
• Waveform: 1,2/50 µs
• Current: 2.5 kA
• Waveform: 8/20 µs
 Energy: 120 J
• 1-Ph. Coupling network
 
The CE-SURGE is a compact EMC test unit designed for testing electromagnetic immunity against pulsed and conducted interference. Demonstrating such immunity is generally a requirement for compliance with the European EMC directive, a necessary step leading to the CE mark.
 
Related Standards:
IEC: IEC 61000-4-05

 

 

Combination Wave Generator PG 7-250
 
Summary:
• Voltage: 7 kV
• Waveform: 1.2 / 50 μs
• Current: 3.5 kA
• Waveform: 8 / 20 μs
• Energy: 250 J
 
The Combination Wave Generator PG 7-250 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100, delivers a standard impulse voltage with waveform 1.2/50μs and, for short-circuited output, a standard impulse current with waveform 8/20μs.
 
Related Standards:
IEC: IEC 61000-4-05

 

 

PG 10-504 Combination Wave Generator
PG 10-504 Combination Wave Generator
 
Summary:
• Voltage: 10 kV
• Waveform: 1.2/50 μs
• Current: 5 kA
• Waveform: 8/20 μs
• Energy: 500 J
 
The Combination Wave Generator PG 10-504 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100, delivers a standard impulse voltage with waveform 1.2/50μs and, for short-circuited output, a standard impulse current with waveform 8/20μs.
 
Related Standards:
IEC: IEC 61000-4-05

 

 

PG 12-804 Combination Wave Generator
PG 12-804 Combination Wave Generator
 
Summary:
• Voltage: 12kV
• Waveform: 1.2/50 μs
• Current: 6 kA
• Waveform: 8/20 μs
 Energy: 800 J
 
The Combination Wave Generator PG 12-804 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100, delivers a standard impulse voltage with waveform 1.2/50μs and, for short-circuited output, a standard impulse current with waveform 8/20μs.
 
Related Standards:
IEC: IEC 61000-4-05

 

PG 24-2k5 Surge Test Generator
 
Summary:
• Voltage: 24 kV
• Waveform: 1.2/50 μs
• Current: 12 kA
• Waveform: 8/20 μs
• Energy: 2500 J
 
The Surge Test Generator PG 24-2500 is a combined impulse current-/impulse-voltage generator which, for high-impedance loads, RL > 100, delivers a standard impulse voltage with waveform 1.2/50μs and, for short-circuited output, a standard impulse current with waveform 8/20μs, as defined by IEC 60. The peak value of the pulse output voltage can be adjusted from 0.5 kV to 24 kV. The peak short circuit current amplitude is 12 kA.
 
Related Standards:
IEC: IEC 61000-4-05, IEC 61643-11

 

 

CE-Tester 2
 
Summary:
• BURST 5kV, 5/50 ns
• SURGE 5kV, 1,2/50µs SURGE 2.5kA, 8/20µs
• 1-Ph. Coupling network
• Voltage dips/variation
• Magnetic field 50/60 Hz
• Magnetic field 8/20 μs
 
The CE-TESTER is a compact EMC test unit designed for testing electromagnetic immunity against pulsed and conducted interference. Demonstrating such immunity is generally a requirement for compliance with the European EMC directive, a necessary step leading to the CE mark. In its basic configuration, the CE-TESTER includes an Electrical Fast Transient Generator (EFTG), a Combination Wave Generator (CWG) and a Coupling-/Decoupling Network (CDN) for single-phase power supply lines.
 
Related Standards:
IEC: IEC 61000-4-04, IEC 61000-4-05, IEC 61000-4-08, IEC 61000-4-09, IEC 61000-4-11, IEC 60060-2, IEC 61000-4-29

 

 

EMC 2015 Impulse Generator
 
Summary:
• EMI-Simulator
• Plug-in system
• Different wave forms
 
The impulse generator system EMC 2015 has been designed for dielectric testing of electric components, over-voltage protectors and electronic circuits according IEC, VDE etc. The basic version generates impulse currents with waveform 8/20 μs and a peak value up to 25 kA. In addition, various other plug-ins are also available.
 
Related Standards:
IEC: IEC 60060-2, IEC 62475-2

 

Request a Quote / Contact Us!

 

 
 

Hilo-Test product Line

HILO-TEST Company Information

HILO-TEST Product Categories:
AC DC Test Equipment
Accessories
Automotive EMC Test Systems
Burst (EFTG) Simulators / Burst Calibration Kit
Coupling Network (CDN)
ESD Generators
High Voltage Dividers
Impulse Current Generators
Impulse Voltage Generators
Miscellaneous Products
Multifunction Generators
Oscillatory wave generator systems
Power Fail Generators
Ring-wave Generators
Shunts
Software
Surge (Hybrid) Generators
Telecom Generators

HILO-TEST PRODUCTS BY STANDARDS CATAGORIES
EMC Test Equipment
CCITT Test Equipment, Series K
 
Component Test Generators
  • • High Voltage Pulse Generators
    • • PG 10-200/PG 12-360 Accessories
    • High Current Pulse Generator
High Voltage Test and Measurement Equipment
  • • AC and DC
    • High Voltage Measurement Equipment
    • Calibration Equipment
Other Products

Reliant EMC Product Lines