Reliant EMC

SAC-10/H Hybrid Semi Anechoic Chamber

Frankonia SAC-10-H Hybrid Semi Anechoic 10m EMC Chamber with Hybrid Absorbers
Frankonia SAC-10/H Hybrid Semi Anechoic 10m EMC Chamber with Hybrid Absorbers
 
Overview
SAC-10/H Hybrid
EMI
CISPR 16-1-4 and ANSI C63.4, full compliant
EMS
IEC/EN 61000-4-3, full compliant
Test distance
up to 10,0m
Volume
ø3,0 m up to ø6,0 m
Special
Hybrid Absorbers
 
The SAC-10/H chambers are Frankonia’s full compliant and customizable EMC testing solutions at 10,0m measuring distance offering various sizes of the Quiet Zone (QZ). Due to the high grade of customization reflecting the demands of our customers, this semi-anechoic chamber is adaptable in size and offers several configuration possibilities. The innovative concept with its impressionable absorber layout achieves exceptional performance for emission and immunity testing.

 

Features
• Frankosorb® Hybrid Absorbers (equal to P2400 Pyramid Absorbers)
• Full compliant EMI/EMS
• Highly customizable solution for any kind of EMC testing and limitless integration of individual applications
• Adjustable chamber size, characteristics and configuration due to different EUT requirements Advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)
• Specialized for ‘out-of-the-range’ EMC test environments
• Turnkey solution
 
Typical Product Standards
Emission
• CISPR 11
• CISPR 12
• CISPR 14
• CISPR 15
• CISPR 25
• CISPR 32
• MIL-STD 461
Immunity
• IEC/EN 61000-4-3
• ISO 11451
• ISO 11452
• MIL-STD 461
• RS 101, RS102, RS103
 
Typical Verification Standards
Emission
• CISPR 16-1-4 and/or ANSI C63.4
Immunity
• IEC/EN 61000-4-3

 

Typical Specifications

Chamber Type
SAC-10-3/H
SAC-10-4/H
SAC-10-5/H
SAC-10-6/H
External dimension
18.380 x 12.830 x 8.550 mm (LxWxH)
19.280 x 13.280 x 8.550 mm (LxWxH)
21.080 x 15.080 x 8.550 mm (LxWxH)
21.680 x 15.680 x 8.700 mm (LxWxH)
Quiet Zone at 3,0m
ø3,0 m
ø3,0 m
ø3,0 m
ø3,0 m
Quiet Zone at 5,0m
ø3,0 m
ø4,0 m
ø5,0 m
ø5,0 m
Quiet Zone at 10,0m
ø3,0 m
ø4,0 m
ø5,0 m
ø6,0 m
Load capacity
up to 80,0 tons; special turntable systems and dynamometer integration possible
Frequency range
9 kHz/ 30 MHz to 18 GHz (option 40 GHz)

 

Performance & Compliance
• Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
• Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

 

Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Interfaces for Franikonia Anechoic Chambers Data Sheet

 

Request a Quote / Contact Us!

 

 

Frankonia product Line