EnglishPortugueseSpanish
DANA SRL Power Supplies

Dana Linear Amplifier
• Linear Amplifier - DLA SERIES
Dana Elecrtronic Loads
• Linear Electronic Loads – DSO Series
• Linear Electronic Loads 0 Volt – DSOT Series
Dana Linear Electronic Switches
• Electronic Switches
Dana Linear Generators for Rail and Trams
• Linear Generators
Dana Digital Interfaces
• Digital Interfaces
Dana Continuous Current Generators
• Linear Continuous Current Generators – DAC Series
Dana Double Regulation Continuous
• Double Regulation Continuous Current Generators – DOC Series
Dana Power Sources
• AC/DC Power Sources – MPS Series
Dana Linear Power Supplies
• Linear Power Supplies
• Linear AC/DC Power Supplies – DA Series
• Linear AC/DC Power Supplies for Photo-voltaic Inverter Testing
• Linear 1000 Vdc Linear Power Supply – DAX-1000• Linear AC/DC Bipolar 2 Quadrant Power Supplies – D2A Series
• Linear AC/DC Bipolar 4 Quadrant Power Supplies – D4A & D4AA Series
• Linear AC/DC Multi Output Power Supplies – DP Series
• Linear AC/DC Bipolar 2 Opposite Quadrant Power Supplies – D2AC Series
• Linear Power Supply for Superconducting Coils
• Start Engine Power Supplies – DAS Series
Dana Double Regulation Power Supplies
• Double Regulation Power Supplies – DO Series
• Double Regulation 2 Quadrant Power Supplies – D2O Series
• Double Regulation Bipolar Opposite 2 Quadrant Power Supplies – D2OC Series
Dana Thystor Regulation Supplies
• Thyristors Regulation AC/DC Power Supplies – DE Series

DANA Company Overview
DANA Data Sheets
Dana SRL Catalog

Request a Quote / Contact Us!

    Manufacturer

    Part Number or Numbers

    DANA- Mono / Double Output Power Supplies

    DP Series


    TECHNICAL DATA

    • Mains Input
      115 or 230 Vac ± 10% 48-400 Hz
    • Line regulation
      better than 50 ppm of output V max for the allowed input variation
    • Voltage and Current Output
      adjustable by a 10 turns potentiometer from “0” to max rated
    • Load regulation for constant V
      from no load to full load better than 50 ppm
    • Load regulation for constant I
      better than 100 ppm of I max from “0” to V max .
    • Ripple and noise
      lower 30 ppm (rms) of V max, measured in V mode
    • Recovery time
      better than 20µs within ± 1% of set voltage from no load to full load.
    • Reaction to remote programming (slew rate)
      1V / µs
    • Stability
      after 20 minutes of preheating, better than 0.1% for 24 hours at 25°C ambient
    • Temperature coefficient
      lower 50 ppm/°C in “voltage mode”;
      lower 100 ppm/°C in “current mode”
    • Ambient temperature
      work 0÷40°C
      storage -10÷50°C
    • Cooling
      forced airDANA Mono Double output

      DANA Mono Double output

    FRONT PANEL CONTROLS

    Power
    switches equipment ON and OFF

    DC
    enables DC output through a dedicated switch (in dual models DCM Master and DCS Slave)

    Check
    V – A – OVP set up push-buttons when the Power Supply is in stand-by

    Section V
    Potentiometer and display (with accuracy of 1.5%) showing output voltage or, by means of Check button, programmed voltage.

    Section A
    Potentiometer and display (with accuracy of 1.5%)
    showing output current or, by means of Check button, programmed current.

    OVP (Over Voltage Protection)
    trimmer allowing to set up “hazard-limit” for the EUT, when picked it up inhibits Power Supply with an alarm LED lighting up

    OT
    Over-temperature alarm of power circuit that puts Power Supply in stand- by mode with an alarm LED lighting up until the end of over temperature

    Remote
    Slider switches selecting working mode of Power Supply from “local programming” to “remote programming” with a LED showing “remote” function

    Master/Slave (Dual output models only)
    switch allowing the function connecting controls of two sections in an optically isolated mode. It also allows parallel or series of the two power sections, in local as well as in remote mode

    M/S
    trimmer allowing to get two separate outputs from the power supply with same or different voltages between 100/100 and 100/50 rate

     

    BACK-PANEL CONTROLS

    Terminal block allowing to switch “remote sense” circuit control from power output plugs to remote sense, to recover a max voltage drop of 0,5 V for cable
    GPAC
    “General Purpose Analog Control” connector to program remotely the Power Supply with 0 ÷ 10 Vdc analog voltage for all his functions and to read feed-back (0 ÷ 10 Vdc) proportional to output Voltage and Current.

    OPTIONS

    PS / PW
    interface to program the Power Supply with IEEE488/RS232 or IEEE488/RS485 standard (with increased dimensions)

    O
    optically isolated controls for remote commands and feed- back

    R
    ears for rack mounting

    DIMENSIONS

    Width: ½ rack = 222mm – rack = 444mm
    Height: 2U rack (89 mm)
    Depth: 365mm (all models)

    DANA DP2C 100-4 PS2 External

    DANA DP2C 100-4 PS2 Internal

    DANA DP Linear AC DC Mulit Output Power Supplies Model Chart

    DANA DP Linear AC DC Multi Output Power Supplies Model Chart

     

    The models in the table are available with voltage and output current on customer request

    3 year Warranty!

     

    ASSOCIATED DOWNLOADS