EnglishPortugueseSpanish

Request a Quote / Contact Us!

Manufacturer

Part Number or Numbers

HILO - EMC TEST EQUIPMENT

HILO-TEST EMC TEST EQUIPMENT BY INDUSTRY STANDARD

INDUSTRY STANDARDS

Data Sheet

Description:

 

SESD 216 ELECTRO STATIC DISCHARGE GENERATOR
simulates disturbances caused by electrostatic discharge
contact discharge up to 10 kV, air discharge up to 16.5 kV
> as specified in IEC 61000-4-2
SESD 230 LECTRO STATIC DISCHARGE GENERATOR
simulates disturbances caused by electrostatic discharge
contact discharge up to 30 kV, air discharge up to 30 kV
ESD 30000 ELECTRO STATIC DISCHARGE GENERATOR
simulates disturbances caused by electrostatic discharge
contact discharge up to 30 kV, air discharge up to 30 kV
as specified in IEC 61000-4-2 and ISO TR 10605
EFTG 4510 ELECTRICAL FAST TRANSIENT GENERATOR
simulates transient disturbances of the mains power supply caused by contact bouncing, waveform 5/50 ns, 0.2 – 5 kV, 1KHz-1MHz burst frequency, specified in IEC 61000-4-4
CE-TESTER

Compact EMC test unit,
designed for testing electromagnetic immunity against
pulsed and conducted interference according to IEC 61000-4-XX

  • Burst up to 5kV
  • Surge up to 5kV
  • Power freq. magnetic field 50Hz
  • Pulsed magnetic field 8/20µs
  • Voltage dips and variation
IPG 612T RING-WAVE GENERATOR
simulates high-voltage transients of the mains power supply caused by switching in the major power system waveform 0.5µs/100 kHz, 6 kV, specified in IEC 61000-4-12, EN 61000-4-12, IEC 1008-1
IPG 2554 OSCILLATORY WAVE GENERATOR
simulates high-voltage transients of the mains power supply caused by switching in gas isolated substations of the major power system, specified in IEC 61000-4-12, EN 61000-4-18 slow damped oscillatory wave 100 kHz, 0 – 3 kV, rep. rate 40Hz slow damped oscillatory wave 1.0 MHz, 0 – 3 kV, rep. rate 400 Hz fast damped oscillatory wave 3/10/30 MHz, 0 – 4 kV, rep. rate 5 kHz
PFS 2516 POWER FAIL SIMULATOR
including motor driven variac 0 – 250 V / 16 A simulates transient interruptions and variation of the power supply voltage specified in IEC 61000-4-11
EFTG 4510 Accessories

Data Sheet

 

Description
Accessories for EFTG 4510
EFTC 2012 Capacitive Coupling Clamp
for capacitive coupling of BURST pulses to screened cables according to IEC 61000-4-4
BCK 400F Burst Calibration Kit
including impulse voltage divider 100:1, input impedance 50 Ohm, used for calibration of burst generators
Coupling-/Decoupling Networks for EFTG 4510
CDN 4416B Coupling-/Decoupling Network
Coupling of BURST – pulses to power supply lines 3 * 400 V, 25 A
 CE Tester Accessories

Data Sheet

Description

 

Accessories for CE-TESTER
VPS 250-16 Variable Power Source
Motor driven variac, control by CE-TESTER
This sub-unit is necessary for generation of voltage variation according to IEC 61000-4-11
HI 100 Helmholtz Coil
Air coil for generation of magnetic fields according to IEC 1000-4-8 / -9
EFTC 2012 Capacitive Coupling Clamp
for capacitive coupling of BURST pulses to screened cables according to IEC 61000-4-4
SCK 105 Surge Calibration Kit
including impulse voltage divider and current viewing resistor, used for calibration of surge generators
BCK 400F Burst Calibration Kit
including impulse voltage divider 100:1, input impedance 50 Ohm, used for calibration of burst generators
Coupling-/Decoupling for CE-TESTER
CDN 4416
CDN 4432
CDN 4463
pulses to power supply lines 3 * 400 V, 16 A, 32 A or 63 A,
surge: max. test voltage  5 kV, 1.2/50µs
burst:  max. Test voltage  5 kV, 5/50ns
CDN 2402 pulses to data lines, 4 * 48 V, 2 A, max. test voltage:
2 kV, 1.2/50µs
CDN 2410 pulses to data lines, 4 * 240 V, 10 A, max. test voltage: 2 kV, 1.2/50µs
CDN 2802 pulses to data lines, 8 * 48 V, 10 A, max. test voltage: 2 kV, 1.2/50µs


Data Sheet

 

Description

 

CAR-TEST-SYSTEM 14 EMC Test System,
designed for testing electromagnetic immunity of the electrical installation of vehicles and components against supply line transients.
The following tests are implemented:
 Immunity to Surge, Pulse # 1, # 2, # 3

 Direct current supply voltage
 Over Voltage, Jump Start
 Slow decrease and increase of supply voltage
 Discontinuities in supply voltage

 Damp Load Test A, Test B
Load switch: 50/100/200A
Various power amplifier possible
according to DIN/ISO 7637-1/2 and ISO 16750-2
CAR-TE14 Transient Emission Test
– with load switch, electronic / mechanical
– with load resistors
according to ISO 7637-1/2
CAR-SS-A1250 Superimposed sinus ac Voltage Generator
0 – 30kHz; 30A
according to ISO 7637-1/2
Load Dump Generator
PG 2804
Compact EMC test unit,
designed for testing electromagnetic immunity of the electrical installation of vehicles and components against supply line transients.
Available impulse waveforms: 5 / Test A+B,
according to ISO 16750-2
 Car Tester Accessories

Data Sheet

Description

 

CDN 2012 Capacitive Coupling Clamp
interference of burst pulses to screened lines
according to IS= 7637-3
SESD 30000 ELECTRO STATIC DISCHARGE GENERATOR
Contact discharge and air discharge up to 30 kV
according to IEC 61000-4-2 and ISO/TR 10605

 


Data Sheet

 

Description

 

CWG Series: COMBINATION WAVE GENERATORS
Pulse voltage 1.2/50µs, Pulse current 8/20µs specified in IEC 61000-4-5, EN 61000-4-5, IEEE587, VDE0847-4-5
IPG 105 COMBINATION WAVE GENERATOR, IPG 105
Pulse voltage 1.2/50µs, – 1.0 kV, Pulse current 8/20µs, – 500 A
PG 2.5-32 COMBINATION WAVE GENERATOR, PG2.5-32
Pulse voltage 1.2/50µs, – 2,5 kV, Pulse current 8/20µs, -1.25 kA
CE-SURGE COMBINATION WAVE GENERATOR, CE-SURGE
Pulse voltage 1.2/50µs, – 5 kV, Pulse current 8/20µs, – 2.5 kA
PG 7-250 COMBINATION WAVE GENERATOR, PG 6-204
Pulse voltage 1.2/50µs, – 6 kV, Pulse current 8/20µs, – 3.0 kA
PG 10-504 COMBINATION WAVE GENERATOR, PG 10-504
Pulse voltage 1.2/50µs, – 10 kV, Pulse current 8/20µs, – 5.0 kA
PG 12-804 COMBINATION WAVE GENERATOR, PG 12-804
Pulse voltage 1.2/50µs, – 12 kV, Pulse current 8/20µs, – 6.0 kA
PG 24-2500 COMBINATION WAVE GENERATOR, PG 24-2500
Pulse voltage 1.2/50µs, – 24 kV, Pulse current 8/20µs, – 12 kA
 CE-SURGE Accessories

Data Sheet

Description

 

 

Accessories for CE-SURGE

 

HI 100 Helmholtz Coil
Air coil for generation of magnetic fields according to IEC 61000-4-8 / -9
SCK 105 Surge Calibration Kit
including impulse voltage divider and current viewing resistor, used for calibration of surge generators
Coupling-/Decoupling Network for CE-SURGE
CDN 4416
CDN 4432
CDN 4463
three-phase power supply lines 3 * 400 V, 16 A, 32 A or 63 A
max. test voltage: 5 kV, 1.2/50µs
CDN 2402 for data lines, 4 * 48 V, 2 A, max. test voltage: 2.5 kV, 1.2/50µs
CDN 2410 for data lines, 4 * 240 V, 10 A, max. test voltage: 2.5 kV, 1.2/50µs
CDN 2802 for data lines, 8 * 48 V, 10 A, max. test voltage: 5 kV, 1.2/50µs
 PG 7-250 Accessories

Data Sheet

Description

 

Accessories for PG 7-250
HI 100 Helmholtz Coil
Air coil for generation of magnetic fields according to IEC 61000-4-8 / -9
SCK 105 Surge Calibration Kit
including impulse voltage divider and current viewing resistor, used for calibration of surge generators
Coupling-/Decoupling Networks for PG 7-250
CDN 6416
Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 16A,
max. Surge test voltage 7 kV, 1.2/50µs
max. Burst voltage 5 kV, 5/50ns
CDN 6432 Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 32A,
max. Surge test voltage 7 kV, 1.2/50µs
max. Burst voltage 5 kV, 5/50ns
CDN 6463 Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 63A,
max. Surge test voltage 7 kV, 1.2/50µs
max. Burst voltage 5 kV, 5/50ns
CDN 2402 Coupling of BURST or SURGE – pulses to data lines, 4 * 48 V, 2 A
CDN 2410 Coupling of BURST or SURGE – pulses to data lines, 4 * 240 V, 10 A
 PG 10-504 Accessories

Data Sheet

Description

 

 Accessories for PG 10-504
HI 100 Helmholtz Coil
Air coil for generation of magnetic fields according to IEC 61000-4-8 / -9
SCK 105 Surge Calibration Kit
including impulse voltage divider and current viewing resistor, used for calibration of surge generators
Coupling-/Decoupling Networks for PG 10-504
CDN 10416 Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 16 A
max. Surge test voltage 10 kV, 1.2/50µs
max. Burst voltage 4.5 kV, 5/50ns
CDN 10432 Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 32 A
max. Surge test voltage 10 kV, 1.2/50µs
max. Burst voltage 4.5 kV, 5/50ns
CDN 10463 Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 63 A
max. Surge test voltage 10 kV, 1.2/50µs
max. Burst voltage 4.5 kV, 5/50ns
CDN 2402 Coupling of BURST or SURGE – pulses to data lines,
4 * 48 V, 2 A bzw. 4 * 240 V, 10 A
CDN 2410 Coupling of BURST or SURGE – pulses to data lines, 4 * 240 V, 10 A

 PG 12-804 Accessories

Data Sheet

Description

 

Accessories for PG 12-804
HI 100 Helmholtz Coil
Air coil for generation of magnetic fields according to IEC 61000-4-8 / -9
SCK 105 Surge Calibration Kit
including impulse voltage divider and current viewing resistor, used for calibration of surge generators
Coupling-/Decoupling Networks for PG 12-804
CDN 12216

Coupling-/Decoupling Network

Coupling of BURST or SURGE – pulses to power supply lines 2 * 240 V, 16 A

Surge: max. test voltage: 12 kV, 1.2/50µs

coupling mode: “line to line”, “line to ground” and “common mode”

Burst:  max. test voltage: 4.5 kV, 5/50ns

according to IEC 61000-4-4 / -5, VDE 0847-4-4 / -5