EnglishPortugueseSpanish

Request a Quote / Contact Us!

    Manufacturer

    Part Number or Numbers

    HILO - EMC TEST EQUIPMENT

    HILO-TEST EMC TEST EQUIPMENT BY INDUSTRY STANDARD

    INDUSTRY STANDARDS

    Data Sheet

    Description:

     

    SESD 216 ELECTRO STATIC DISCHARGE GENERATOR
    simulates disturbances caused by electrostatic discharge
    contact discharge up to 10 kV, air discharge up to 16.5 kV
    > as specified in IEC 61000-4-2
    SESD 230 LECTRO STATIC DISCHARGE GENERATOR
    simulates disturbances caused by electrostatic discharge
    contact discharge up to 30 kV, air discharge up to 30 kV
    ESD 30000 ELECTRO STATIC DISCHARGE GENERATOR
    simulates disturbances caused by electrostatic discharge
    contact discharge up to 30 kV, air discharge up to 30 kV
    as specified in IEC 61000-4-2 and ISO TR 10605
    EFTG 4510 ELECTRICAL FAST TRANSIENT GENERATOR
    simulates transient disturbances of the mains power supply caused by contact bouncing, waveform 5/50 ns, 0.2 – 5 kV, 1KHz-1MHz burst frequency, specified in IEC 61000-4-4
    CE-TESTER

    Compact EMC test unit,
    designed for testing electromagnetic immunity against
    pulsed and conducted interference according to IEC 61000-4-XX

    • Burst up to 5kV
    • Surge up to 5kV
    • Power freq. magnetic field 50Hz
    • Pulsed magnetic field 8/20µs
    • Voltage dips and variation
    IPG 612T RING-WAVE GENERATOR
    simulates high-voltage transients of the mains power supply caused by switching in the major power system waveform 0.5µs/100 kHz, 6 kV, specified in IEC 61000-4-12, EN 61000-4-12, IEC 1008-1
    IPG 2554 OSCILLATORY WAVE GENERATOR
    simulates high-voltage transients of the mains power supply caused by switching in gas isolated substations of the major power system, specified in IEC 61000-4-12, EN 61000-4-18 slow damped oscillatory wave 100 kHz, 0 – 3 kV, rep. rate 40Hz slow damped oscillatory wave 1.0 MHz, 0 – 3 kV, rep. rate 400 Hz fast damped oscillatory wave 3/10/30 MHz, 0 – 4 kV, rep. rate 5 kHz
    PFS 2516 POWER FAIL SIMULATOR
    including motor driven variac 0 – 250 V / 16 A simulates transient interruptions and variation of the power supply voltage specified in IEC 61000-4-11
    EFTG 4510 Accessories

    Data Sheet

     

    Description
    Accessories for EFTG 4510
    EFTC 2012 Capacitive Coupling Clamp
    for capacitive coupling of BURST pulses to screened cables according to IEC 61000-4-4
    BCK 400F Burst Calibration Kit
    including impulse voltage divider 100:1, input impedance 50 Ohm, used for calibration of burst generators
    Coupling-/Decoupling Networks for EFTG 4510
    CDN 4416B Coupling-/Decoupling Network
    Coupling of BURST – pulses to power supply lines 3 * 400 V, 25 A
     CE Tester Accessories

    Data Sheet

    Description

     

    Accessories for CE-TESTER
    VPS 250-16 Variable Power Source
    Motor driven variac, control by CE-TESTER
    This sub-unit is necessary for generation of voltage variation according to IEC 61000-4-11
    HI 100 Helmholtz Coil
    Air coil for generation of magnetic fields according to IEC 1000-4-8 / -9
    EFTC 2012 Capacitive Coupling Clamp
    for capacitive coupling of BURST pulses to screened cables according to IEC 61000-4-4
    SCK 105 Surge Calibration Kit
    including impulse voltage divider and current viewing resistor, used for calibration of surge generators
    BCK 400F Burst Calibration Kit
    including impulse voltage divider 100:1, input impedance 50 Ohm, used for calibration of burst generators
    Coupling-/Decoupling for CE-TESTER
    CDN 4416
    CDN 4432
    CDN 4463
    pulses to power supply lines 3 * 400 V, 16 A, 32 A or 63 A,
    surge: max. test voltage  5 kV, 1.2/50µs
    burst:  max. Test voltage  5 kV, 5/50ns
    CDN 2402 pulses to data lines, 4 * 48 V, 2 A, max. test voltage:
    2 kV, 1.2/50µs
    CDN 2410 pulses to data lines, 4 * 240 V, 10 A, max. test voltage: 2 kV, 1.2/50µs
    CDN 2802 pulses to data lines, 8 * 48 V, 10 A, max. test voltage: 2 kV, 1.2/50µs


    Data Sheet

     

    Description

     

    CAR-TEST-SYSTEM 14 EMC Test System,
    designed for testing electromagnetic immunity of the electrical installation of vehicles and components against supply line transients.
    The following tests are implemented:
     Immunity to Surge, Pulse # 1, # 2, # 3

     Direct current supply voltage
     Over Voltage, Jump Start
     Slow decrease and increase of supply voltage
     Discontinuities in supply voltage

     Damp Load Test A, Test B
    Load switch: 50/100/200A
    Various power amplifier possible
    according to DIN/ISO 7637-1/2 and ISO 16750-2
    CAR-TE14 Transient Emission Test
    – with load switch, electronic / mechanical
    – with load resistors
    according to ISO 7637-1/2
    CAR-SS-A1250 Superimposed sinus ac Voltage Generator
    0 – 30kHz; 30A
    according to ISO 7637-1/2
    Load Dump Generator
    PG 2804
    Compact EMC test unit,
    designed for testing electromagnetic immunity of the electrical installation of vehicles and components against supply line transients.
    Available impulse waveforms: 5 / Test A+B,
    according to ISO 16750-2
     Car Tester Accessories

    Data Sheet

    Description

     

    CDN 2012 Capacitive Coupling Clamp
    interference of burst pulses to screened lines
    according to IS= 7637-3
    SESD 30000 ELECTRO STATIC DISCHARGE GENERATOR
    Contact discharge and air discharge up to 30 kV
    according to IEC 61000-4-2 and ISO/TR 10605

     


    Data Sheet

     

    Description

     

    CWG Series: COMBINATION WAVE GENERATORS
    Pulse voltage 1.2/50µs, Pulse current 8/20µs specified in IEC 61000-4-5, EN 61000-4-5, IEEE587, VDE0847-4-5
    IPG 105 COMBINATION WAVE GENERATOR, IPG 105
    Pulse voltage 1.2/50µs, – 1.0 kV, Pulse current 8/20µs, – 500 A
    PG 2.5-32 COMBINATION WAVE GENERATOR, PG2.5-32
    Pulse voltage 1.2/50µs, – 2,5 kV, Pulse current 8/20µs, -1.25 kA
    CE-SURGE COMBINATION WAVE GENERATOR, CE-SURGE
    Pulse voltage 1.2/50µs, – 5 kV, Pulse current 8/20µs, – 2.5 kA
    PG 7-250 COMBINATION WAVE GENERATOR, PG 6-204
    Pulse voltage 1.2/50µs, – 6 kV, Pulse current 8/20µs, – 3.0 kA
    PG 10-504 COMBINATION WAVE GENERATOR, PG 10-504
    Pulse voltage 1.2/50µs, – 10 kV, Pulse current 8/20µs, – 5.0 kA
    PG 12-804 COMBINATION WAVE GENERATOR, PG 12-804
    Pulse voltage 1.2/50µs, – 12 kV, Pulse current 8/20µs, – 6.0 kA
    PG 24-2500 COMBINATION WAVE GENERATOR, PG 24-2500
    Pulse voltage 1.2/50µs, – 24 kV, Pulse current 8/20µs, – 12 kA
     CE-SURGE Accessories

    Data Sheet

    Description

     

     

    Accessories for CE-SURGE

     

    HI 100 Helmholtz Coil
    Air coil for generation of magnetic fields according to IEC 61000-4-8 / -9
    SCK 105 Surge Calibration Kit
    including impulse voltage divider and current viewing resistor, used for calibration of surge generators
    Coupling-/Decoupling Network for CE-SURGE
    CDN 4416
    CDN 4432
    CDN 4463
    three-phase power supply lines 3 * 400 V, 16 A, 32 A or 63 A
    max. test voltage: 5 kV, 1.2/50µs
    CDN 2402 for data lines, 4 * 48 V, 2 A, max. test voltage: 2.5 kV, 1.2/50µs
    CDN 2410 for data lines, 4 * 240 V, 10 A, max. test voltage: 2.5 kV, 1.2/50µs
    CDN 2802 for data lines, 8 * 48 V, 10 A, max. test voltage: 5 kV, 1.2/50µs
     PG 7-250 Accessories

    Data Sheet

    Description

     

    Accessories for PG 7-250
    HI 100 Helmholtz Coil
    Air coil for generation of magnetic fields according to IEC 61000-4-8 / -9
    SCK 105 Surge Calibration Kit
    including impulse voltage divider and current viewing resistor, used for calibration of surge generators
    Coupling-/Decoupling Networks for PG 7-250
    CDN 6416
    Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 16A,
    max. Surge test voltage 7 kV, 1.2/50µs
    max. Burst voltage 5 kV, 5/50ns
    CDN 6432 Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 32A,
    max. Surge test voltage 7 kV, 1.2/50µs
    max. Burst voltage 5 kV, 5/50ns
    CDN 6463 Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 63A,
    max. Surge test voltage 7 kV, 1.2/50µs
    max. Burst voltage 5 kV, 5/50ns
    CDN 2402 Coupling of BURST or SURGE – pulses to data lines, 4 * 48 V, 2 A
    CDN 2410 Coupling of BURST or SURGE – pulses to data lines, 4 * 240 V, 10 A
     PG 10-504 Accessories

    Data Sheet

    Description

     

     Accessories for PG 10-504
    HI 100 Helmholtz Coil
    Air coil for generation of magnetic fields according to IEC 61000-4-8 / -9
    SCK 105 Surge Calibration Kit
    including impulse voltage divider and current viewing resistor, used for calibration of surge generators
    Coupling-/Decoupling Networks for PG 10-504
    CDN 10416 Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 16 A
    max. Surge test voltage 10 kV, 1.2/50µs
    max. Burst voltage 4.5 kV, 5/50ns
    CDN 10432 Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 32 A
    max. Surge test voltage 10 kV, 1.2/50µs
    max. Burst voltage 4.5 kV, 5/50ns
    CDN 10463 Coupling of BURST or SURGE – pulses to power supply lines 3 * 400 V, 63 A
    max. Surge test voltage 10 kV, 1.2/50µs
    max. Burst voltage 4.5 kV, 5/50ns
    CDN 2402 Coupling of BURST or SURGE – pulses to data lines,
    4 * 48 V, 2 A bzw. 4 * 240 V, 10 A
    CDN 2410 Coupling of BURST or SURGE – pulses to data lines, 4 * 240 V, 10 A

     PG 12-804 Accessories

    Data Sheet

    Description

     

    Accessories for PG 12-804
    HI 100 Helmholtz Coil
    Air coil for generation of magnetic fields according to IEC 61000-4-8 / -9
    SCK 105 Surge Calibration Kit
    including impulse voltage divider and current viewing resistor, used for calibration of surge generators
    Coupling-/Decoupling Networks for PG 12-804
    CDN 12216

    Coupling-/Decoupling Network

    Coupling of BURST or SURGE – pulses to power supply lines 2 * 240 V, 16 A

    Surge: max. test voltage: 12 kV, 1.2/50µs

    coupling mode: «line to line», «line to ground» and «common mode»

    Burst:  max. test voltage: 4.5 kV, 5/50ns

    according to IEC 61000-4-4 / -5, VDE 0847-4-4 / -5