EnglishPortugueseSpanish

Request a Quote / Contact Us!

Manufacturer

Part Number or Numbers

HILO - Miscellaneous Products

Miscellaneous Products

 HILO-TEST Miscellaneous Products

 HCC Capacitor charger

 HCS 3-30 Capacitor Discharge Test Setup

 IPG 250 Pulse generator

 IT 5413 High-Voltage Impulse Transformer

 IT 5425 Impulse Transformer

 MCT 5004 Multi Channel Trigger Unit

 Miscellaneous Products Downloads

 TEM 2000 Measuring Cell

 USD 3801 & USD 3802 Ultrasonic Detectors

 

HILO-TEST Miscellaneous Products 

In this category you will find devices that cannot be clearly assigned to a product category.

 

 

IPG 250 Pulse generator 

IPG 250 Pulse generator

 

Summary:

• Pulse generator

• Measuring the step response

• Different operational modes

 

The pulse generator IPG 250 is designed for measuring the step response of high-impedance networks, for instance voltage dividers, oscilloscope probes etc. The generator excels by calibrated adjustment of output amplitude, short rise time and flat pulse top. The output pulse amplitude can be adjusted by use of a 10-turn potentiometer from 0 to 250 V. Positive and negative polarity can be selected.

 

 IPG 250 Pulse Generator Data Sheet

 

 

HCC Capacitor charger 

 

Summary:

• Capacitor charger

• 5″ touch control unit

 

The HCC consists essentially of a control unit, a capacitor charger and other auxiliary equipment for the operation of generators.

 

 HCC Capacitor charger Data Sheet

 

 

HCS 3-30 Capacitor Discharge Test Setup 

 

Summary:

• Capacitor discharge test setup

• Loading voltage: 3 kV

• Current amplitude: 2 x 15 kA

• optical pulse triggering

 

The surge current testing device HCS 3-30 is used for surge current testing of capacitor windings. The capacitor to be tested is on an adjustable voltage, 0,005 – 3000 V, charged and then discharged via a triggerable switch.

 

 HCS 3-30 Capacitor Discharge Test Setup Data Sheet

 

 

IT 5413 High-Voltage Impulse Transformer 

IT 5413 high-voltage impulse transformer

 

Summary:

• Impulse transformer

• Triggering spark gaps

• Input: 400 Vs

• Output: 40 kVs

 

The high-voltage impulse transformer IT 5413 is designed for triggering spark gaps, flash lamps etc. Typical applications are high-voltage impulse technology, laser- and plasma physics.

 

 IT 5413 High-Voltage (HV) Impulse Transformer Data Sheet

 

 

IT 5425 Impulse Transformer 

IT 5425 Impulse transformer

 

Summary:

• Impulse transformer

• Triggering spark gaps

• Input: 400 Vs

• Output: 2000 Vs

 

The impulse transformer IT 5425 and the transformer modules TM 410 and TM 510 are suitable for triggering Ignitrons. The impulse transformer IT 5425 has a high insulating voltage between primary and secondary. It can be used with 10 kV= working voltage.

 

 IT 5425 High-Voltage (HV) Impulse Transformer Data Sheet

 

 

USD 3801 & USD 3802 Ultrasonic Detectors 

USD 3801 & USD 3802 ultrasonic detectors

 

Summary:

• Ultrasonic detectors

• with optical sight

 

External partial discharges at high-voltage electrodes (corona) possess an acoustic spectrum, which extends to the ultrasonic region. Because of the strong directivity of high frequency sound waves, ultrasonic detectors do not only allow detection, but also the localization of corona discharges, for instance, in switch yards, high-voltage test set-ups or transmission lines. The ultrasonic detector USD 38O1/38O2 operates at a frequency of approx. 33 kHz that is particularly suitable for external partial discharge detection. The combination of a highly directional ultrasonic microphone and a parabolic reflector system allows an exceptional directivity of the acoustic sensitivity. The microphone output signal is picked up by a selective amplifier and transformed into an audible signal. This allows a simple evaluation of the partial discharge intensity by headphones.

 

 USD 3801 & USD 3802 ultrasonic detectors Data Sheet

 

 

TEM 2000 Measuring Cell 

TEM 2000 Measuring Cell

 

Summary:

• TEM – Measuring Cell

• Measuring dynamic: 80 dB

• Frequency range: 0.01 – 1000 MHz

• Wave resistance: 50 Ω

 

The TEM – Measuring Cell TEM -2000 permits the measurement of the screening attenuation of electrical conducting plastics, conducting laminated plastics, screening materials and braids.

 

 TEM 2000 Measuring Cell Data Sheet

 

 

MCT 5004 Multi Channel Trigger Unit 

MCT 5004 Multi channel trigger unit

 

Summary:

• Multi channel trigger unit

• 4 channels

• delay time for each channel, adjustable

 

The trigger module generate impulse voltage with peak value of up to 500 V. They are designed for triggering spark gaps, ignitrons, thyratrons etc. using suitable trigger transformers. Rise time of output voltage is less than 200 ns. Low-inductance capacitors and special semiconductor switch allow short circuit current up to 200 A. The output of the trigger module is short-circuit-proof. Single shot or repetitive triggering can be achieved. The several types available differ concerning stored energy and max. repetition rate.

 

 MCT 5004 Multi Channel Trigger Unit Data Sheet

 

 Miscellaneous Products Downloads 

Data Sheet

 

Description

 

 

High voltage power supplies, Capacitor charging units

 

HSN *** High voltage switch mode power supplies
HCN *** Capacitor charging units
HVG *** S Precision high voltage power supplies with series regulator
Trigger Modules
TMS 2403,
TMS 2404,
TMS 2405,
TMS 2406
Trigger module
MCT 5002, MCT 5004 Multi channel trigger unit
Trigger transformers
IT 5413 Trigger transformers for ignitions
TS 410, TS 510, IT 5425 Trigger transformer for spark gaps
Miscellaneous
STT 250 Anti interference isolating transformer
ITT 250-20 Isolating transformer
HS 10…HS 50 High voltage ground switch
USD 3801/3802 Ultrasonic detector for e.g. partial discharge
TEM 2000 TEM Test cell