HILO - SAFETY TEST CABINETS

Safety Test Cabinets

 PA 503 Safety Test Cabinet

 PA 505 Safety Test Cabinet

 PA 525 Safety Test Cabinet

 PU 12 A-B DUT Switchover

 Safety Test Cabinets

 

PA 503 Safety Test Cabinet 

PA 503 Safety test cabinet

 

Summary:

• Safety test cabinet

• Test voltage: 6 kV / 12 kV

• Dimensions W*H*D: 470 * 280 * 490 mm³

 

The safety test cabinet PA 503 is designed for high-voltage testing of components and PCB’s etc. The transparent cabinet prevents accidental contact with live parts of the test object, yet allows observation of the test object during testing.

 

 HILO-TEST PA 503 Safety Test Cabinet Data Sheet

 

 

PA 505 Safety Test Cabinet 

PA 505 Safety test cabinet

 

Summary:

• Safety test cabinet

• Test voltage: 10 kV

• Dimensions W*H*D: 440*250*500 mm³

 

The safety test cabinet PA 505/ PA 525 is designed for high-voltage testing of components and PCB’s etc. The transparent cabinet prevents accidental contact with live parts of the test object, yet allows observation of the test object during testing.

 

 HILO-TEST PA 505 Safety Test Cabinet Data Sheet

 

 

PA 525 Safety Test Cabinet 

PA 525 Safety test cabinet

Summary:

• Safety test cabinet

• Test voltage: 12 kV

• Dimensions W*H*D: 440*250*500 mm³

 

The safety test cabinet PA 505/ PA 525 is designed for high-voltage testing of components and PCB’s etc. The transparent cabinet prevents accidental contact with live parts of the test object, yet allows observation of the test object during testing.

 

 HILO-TEST PA 525 Safety Test Cabinet Data Sheet

 

PU 12 A-B DUT Switchover 

HILO-TEST PU 12 A-B DUT Switchover

 

Summary:

• DUT switchover

• High voltage test of devices

 

For high-voltage testing of components, a DUT switchover is available for different pulse generators.

 

By using the PU 12 A-B DUT Switchover the testing time be significantly reduced and increased the throughput significantly. The specimens are contacted via test adapter that new line during the test can be fitted and replaced quickly. Direct testing of 8/10/12 or 15 individual specimens or the “Differential / common mode” testing the a / b wires of IT equipment can be realized will. The control of the PU 12 A-B DUT Switchover done from the test generator.

The specimens are covered during the test by a safety test.

Of the Following the test generator is carried coaxially on the back of the units. To this Thus achieved a high degree of personal safety for the operating personnel.

Block diagram, by way of example:

To monitor the test quantities can pulse voltage divider and / or Current viewing resistors are integrated into the PU 12 A-B DUT Switchover.

 

 HILO-TEST PU 12 A-B DUT Switchover Data Sheet

 

Safety Test Cabinets 

Data Sheet

 

Description

 

PA 503 Safety test cabinet
Test space ca. W*H*D: 400 / 140 / 250 
PA 501/502 Safety test cabinet
Test space ca. W*H*D: 440 / 180 / 300           
PA 505/525 Safety test cabinet
Test space ca. W*H*D: 400 / 250 / 400 
PA 504 Safety test cabinet
Test space ca. W*H*D: 490 / 300 / 300