EnglishPortugueseSpanish
DANA SRL Power Supplies

Dana Linear Amplifier
• Linear Amplifier - DLA SERIES
Dana Elecrtronic Loads
• Linear Electronic Loads – DSO Series
• Linear Electronic Loads 0 Volt – DSOT Series
Dana Linear Electronic Switches
• Electronic Switches
Dana Linear Generators for Rail and Trams
• Linear Generators
Dana Digital Interfaces
• Digital Interfaces
Dana Continuous Current Generators
• Linear Continuous Current Generators – DAC Series
Dana Double Regulation Continuous
• Double Regulation Continuous Current Generators – DOC Series
Dana Power Sources
• AC/DC Power Sources – MPS Series
Dana Linear Power Supplies
• Linear Power Supplies
• Linear AC/DC Power Supplies – DA Series
• Linear AC/DC Power Supplies for Photo-voltaic Inverter Testing
• Linear 1000 Vdc Linear Power Supply – DAX-1000• Linear AC/DC Bipolar 2 Quadrant Power Supplies – D2A Series
• Linear AC/DC Bipolar 4 Quadrant Power Supplies – D4A & D4AA Series
• Linear AC/DC Multi Output Power Supplies – DP Series
• Linear AC/DC Bipolar 2 Opposite Quadrant Power Supplies – D2AC Series
• Linear Power Supply for Superconducting Coils
• Start Engine Power Supplies – DAS Series
Dana Double Regulation Power Supplies
• Double Regulation Power Supplies – DO Series
• Double Regulation 2 Quadrant Power Supplies – D2O Series
• Double Regulation Bipolar Opposite 2 Quadrant Power Supplies – D2OC Series
Dana Thystor Regulation Supplies
• Thyristors Regulation AC/DC Power Supplies – DE Series

DANA Company Overview
DANA Data Sheets
Dana SRL Catalog

Request a Quote / Contact Us!

    Manufacturer

    Part Number or Numbers

    DANA-Linear Electronic Loads 0 Volt – DSOT Series

    0 VOLTS DSOT SERIES TECHNICAL FEATURES

    Mains Input

    115 or 230 Vac ±10% 50-60 Hz

    Current – Resistance – Power – Voltage
    adjustable from “0” to max rated value

    Regulation for constant I
    better than 100 ppm

    Regulation for constant R
    better than 100 ppm

    Regulation for constant P
    better than 100 ppm

    Regulation for constant V
    better than 50 ppm

    Reaction Time
    better than 1 V / µs and 8 A / µs

    Remote programming and feed-back (GPAC)
    Opto-insulated analog signal 0-10Vdc
    Linearity better than 0.3% Drift better than 1.5mV/°C

    Stability
    Better than 50 ppm over 24 h at 25°C, after 20 minutes warm up
    Temperature coefficient
    better than 50 ppm/°C

    Ambient temperature
    work 0÷40°C
    storage -10÷50°C

    Cooling
    forced ventilation

     

     

    DANA DSOT Series Linear Electronic Load 0 Volt Front Panel

    DANA DSOT Series Linear Electronic Load 0 Volt Front Panel

     

    FRONT PANEL CONTROLS

    Power
    switches ON and OFF the device

    Stand-by
    switch that enables the device to carry out the functions which are armed.

    Function
    V – R – A – P slide switches to enable the device to carry out the select functions ( functions V and P are optional).

    GPAC – GPIB / RS
    slide switches to select the interface used for remote programming. GPAC, analog programming between 0 – 10 Vdc and feedback 0 – 10 Vdc. GPIB (option), programming by an interface IEEE488 –
    RS232/485.

    Remote controls
    V – R – A – P slide switches to set programming mode of functions in local o remote mode.

    Check
    push button to setting the functions when the device is in stand-by, suitable also with remote programming.

    GND
    ground connector

    +/-
    input plugs available also on back panel.

    Section Vin (optional)
    10 turns potentiometer to calibrate the input chosen work voltage. Voltage input digital display (with accuracy ±1,5%)

    Section R
    10 turns potentiometer to calibrate the chosen work resistance. Work resistance digital display (with accuracy ±1,5%)

    Section A
    10 turns potentiometer to calibrate the input chosen work current. Work current digital display (with accuracy ±1,5%)

    Section P (optional)
    10 turns potentiometer to calibrate max input chosen work power. Work power digital display (with accuracy ±1,5%)

    APP
    alarm LED of inversion polarity of power cables with immediately inhibits of device.

    OVP
    alarm LED that indicates the overcoming of maximum voltage work admitted on input.
    Its intervention inhibits the device.

    OT
    alarm LED for over temperature on the power section, its intervention inhibit the device

    BACK PANEL CONTROLS

    GPAC
    “General Purpose Analogical Control” connector to be used to control electronic load adjustments with 0 – 10
    Vdc analog voltage for all remote functions and to read all functions feed-back

    GPIB/RS (option)
    Connectors to program interface IEEE488 and RS232/485
    +/-
    input plugs available also on the front panel

    OPTIONS

    PS
    interface to program electronic load with standard IEEE488/RS232

    PW
    interface to program electronic load with standard IEEE488/RS485

    V
    option in order to work the load also in “constant voltage” mode

    P
    option in order to work the load also in “constant power” mode

     

     

    DANA DSOT Series Linear Electronic Load 0 Volt Model Description Chart

    DANA DSOT Series Linear Electronic Load 0 Volt Model Description Chart
    The models in the table are available with voltage and input current on customer request
    ORDER EXAMPLE

    DANA DSOT Series Linear Electronic Load 0 Volt Order Example

     

    3 year Warranty!

    ASSOCIATED DOWNLOADS

    DANA DSO Series Linear Electronic Loads DANA DSOT Series 0 Volt Linear Electronic Load

    DANA Product Catalog DANA Product Catalog

    DANA Product LIne SnapShot DANA Product Line Snapshot