SEIBERSDORF PRODUCTS
Antennas
• PLA-R Precision Loop Antenna Receive
• PLA-SET Precision Loop Antenna Set For Site Validation
• POD 16 And POD 618 Precision Omnidirectional Dipoles Antennas
• PRD-Precision Reference Dipole
• PCD 3100 Precision Conical Dipole
• PCD 8250 – Precision Conical Dipole
Antenna Sets
• MS1 - Site VSWR Set
• MS2 - POD Antenna Set
• MS3 - MS1 Site VSWR Set without CalStan Software
• MS4 - Site VSWR Set - Automatic
• MS5 - PLA-Set for NSA validation
Antenna Site VSWR Positioners
CalStan 11.0 – RF Measurement Software
Comb Generators RefRad
Site Validation Services
• Absorber Return Loss - 200 MHz - 18 GHz
• ALSE – Absorber Lined Shielded Enclosure Measurements
• Ambient Noise Measurement
• Antenna Calibration Test Site Validation CISPR 16-1-5 30 MHz - 1 GHz
• Automotive Component Test Site Validation CISPR 25 150 KHz - 3 GHz
• Chamber FActor CENELEC R210-003 30 MHz - 1 GHz
• CTIA Ripple Test for Mobile Station 722 MHz - 2132.5 MHz
• CTIA Validation
• Field Uniformity Measurement
• Freespace VSWR Measurements
• NSA – Normalized Site Attenuation
• Shielding Effectiveness Measurement
• Site VSWR Measurement
• Table Influence
• Transmission Loss 1 Ghz - 40 Ghz
SEIBERSDORF LABORATORIES
Seibersdorf Laboratories Company
Seibersdorf Laboratories Data Sheets
Seibersdorf Laboratories Product List
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
Shielding Effectiveness Measurement
Seibersdorf Laboratories Shielding Effectiveness
Measurement Description
The Shielding Effectiveness (SE) is measured in accordance with:
Mil-Std. 285
NSA 65-6
EN 50147 1
Typical measurement frequencies are: 10 kHz, 100 kHz, 1 MHz, 10 MHz, 30 MHz, 100 MHz, 500 MHz, 1 GHz, 10 GHz, 18 GHz, 26.5 GHz and 40 GHz.
Any selection of these frequencies is possible, any other frequencies possible upon request.
The exact location of the test points will be defined together with the customer on site as it is necessary to have full access to all test points.
A leakage test at 433 MHz will be performed when requested at time of order.
Please nominate an assistant to our engineer for setting up the equipment and to handle ladders, tripods and the like.
Test equipment (calibrated spectrum analyzer, signal generator, calibrated power attenuators, suitable transmit and receive antennas, power amplifiers, pre-amplifiers, antenna masts (tripods) and RF-cables) can be provided upon request.
Seibersdorf Laboratories Accredited re Calibration Service for EMC Test Sites Data Sheet
Seibersdorf Laboratories RF Engineering Accredited Site Validation Data Sheet