SHIELDING INTEGRITY SERVICES SITE VALIDATION
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
Site VSWR Measurement
Shielding Integrity Services Site VSWR Measurement
Measurement Description
The test method is established and described by the International Electrotechnical Commission (IEC) as a means of verifying standardized performance of a fully anechoic chamber which generally has been temporarily converted from a semi-anechoic chamber.
The most recent specification describing this test method is CISPR 16-4-1 (2010) + A1 (2012) + A2 (2017), Clause 8: Specification for radio disturbance and immunity measuring apparatus and methods- Part 1-4.
Site VSWR validations are performed from 1 GHz – 18 GHz.