    DC BIAS SOURCE DBS-20D

    Bias Source DBS-20D 20A, 10mA, steps

     

    • Precise Control at each 10mA Steps from 0A to 20A
    • Frequency Response 10kHz~30MHz
    • Adaptable to use with Impedance Analyzer or LCR Meter

     

    EMCIS DC Bias Source DBS-20D

    Key Features

     

    • Analysis of Functional Characteristics of Inductor or Core

     

    • Precious Control at each 10mA steps from 0A to 20A

     

    • Wide Option covering 10kHz~30MHz Frequency range

     

    • Use with Impedance Analyzer or LCR Meter

     

    • Insertion Loss Measurement (Max 100MHz)

     

    • Useful for inductor and core products feature design.
    • Quality control of Inductor and Cores

     

    System Configuration

    EMCIS DBS-20D System Configuration

     

    Specifications

     

    MODEL DBS-20D
    Frequency Range L ,Z: 10KHz~30MHz
    Frequency Range Attenuation: 10KHz~100MHz
    Output Current Range 0~20A  Steps of 10mA
    Measured L , Z , Attenuation
    Power supply AC 220V 60Hz
    Operating Temperature 0~35 ℃
    Dimensions (W X H X D) mm W: 420   H: 214   D: 489
    Weight 35kg

     

    Accessories

     

    • DBS-03CB, SMA-MM-400, DBS-03CL (10KHz ~ 5MHz)

     • DBS-03EB, N20-MM-600, DBS-03EL (10KHz ~ 30MHz)
    • DBS-003A : Attenuation (10KHz ~ 100MHz)

     • BNC-MM-1000 : BNC to BNC Cable (1m)

     • DBS-Terminal : Terminal type connector
    • DBS-SMD : SMD Measurement

     