EMCIS PRODUCT LINE
DC Bias Sources
• DC Bias Source DBS-20D 20A, 10mA steps
• DC Bias Source DBS-50D 50A, 10mA steps
EMI Analyzers
• EA-100
• EA-300
• EA-2100
Filter Analyzers
• FA-2100
• FA-300
Filter Design Kits
• Filter Design Kit FTK-01
• Filter Design Kit FTK-05
LISN
• LN LISN Product Line
Near-Field Probe Kit
Reference Source CRS-1530
Transient Limiter – TL SeriesVisualization Analyzer – VA-100
EMCIS Company Overview
EMCIS Data Sheets
EMCIS Product List
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
EMCIS EMI Analyzer EA-2100
EMI Analyzer EA-2100
• World-first innovative EMI noise analysis and measuring Instruments
• Powerful capability to minimize EMI debugging period
• Maximizing effective EMI filter design and components selection
EMCIS EMI Analyzer EA-2100
Characteristics
•Only with currently used spectrum analyzer, the measured
noises (Line 1 & Line 2) are just “mixture of Differential-mode
& Common-mode”. By analyzing, separating, and showing each individual noise, Line 1, Line 2, Differential-mode, and Common-mode, the EA-2100 provides the real & exact noise analysis and solution.
•Minimizing EMI debugging period
•Capable to design the most effective EMI filter and its components selection
•Capable to analyze the noises by its sources and routes
– useful to provide noise solution process and its related components developments.
•Re-design of finished products to maximize its specification and cost reduction by using the most suitable components.
•Analyzing power line noise in production lines, and provide protect any malfunction caused by the noises.
•EA-2100 can be used any brand of spectrum analyzer and/or
EMI receiver now being used on the field.
– minimizing investment cost
– maximizing the capability of the used instruments
•By analyzing power line circumstance, provides the most most stable measuring basis
•State-of-art design and easy & simple operation
Main Function
•Upgraded capability covering wider frequency range ;
– Full range of Conducted ; up to 30MHz
– major field of Radiated ; up to 300MHz
•Set up the line
– Connect Signal Output of LISN to Input of EA-2100
– Connect Output of EA-2100 to Input of spectrum analyzer/EMI receiver
•Operation
Operating by push-button on front panel
– Simply and Easy
Selecting the Measurement Modes ; Test and Analysis
– Test Mode : measurement of L1 and L2
– Analysis Mode : Differential and Common-mode
Selecting the Noise Modes ; L1, L2, DM, CM
– LOW ; for Conducted range (9KHz ~ 30MHz)
– HIGH ; for Radiated field (30MHz ~ 300MHz)
Control button and Display
Line 1 Noise Chart
Line 2 Noise Chart
Differential Mode Noise Chart
Common Mode Noise Chart
System Configuration