Model #
|
Product Description
|
GTEM
|
|
GTEM 250
|
GTEM-Cell 250 – Assembled and Ready to Use Input connector: N, Nominal impedance: 50, Frequency range: 1MHz-20GHz, Typical VSWR (medium value): 1:1.2, Typical VSWR at critical frequency: <1:1.6, Max Input power, W continuous/*pulsed: 500*/2Kw, Mains connectors: Fix/CEE, Main Switch 16A magneto-thermal, Input Socket IEC plug 16Aac (Single phase + ground), «Output Socket Schuko tape 16Aac (Single phase +,ground) for EUT», Ground connection M6, AC mains filter 16A 250V /2 wires +ground, AC/DC filter 6A/2 wires 250V, Wave guide for fibre optic leads (3 couple), Media RF feed-thru N type connector: QTY 1, Media RF feed-thru SMA type connector: QTY 2, Window in door: 24Wx14.5H cm Diam., Technical panel pre-drilled for options, Outer 127Lx64Wx44H cm, Door W30x23H cm, Weight 40 Kg. Approx., Max. test volume: 20Lx20Wx15H cm, Defined test Vol. +/-3dB <1000MHz (8.5Lx8Wx8.5H cm), Septum height: 250mm Shipping Crate Included. 75x129x66cm, Total Shipping Weight 55kg
|
GTEM 400
|
GTEM Cell Frequency range: 100kHz to 20GHz Maximum power-input, W continuous/pulsed*:500*/1000 Dimensions:2.20m x1.22m x 0.83m (LxWxH) Door size: 40cm x 40cm (WxH) Maximum EUT-Size: 35cm x 40cm x 25cm (LxWxH) Size of uniform area (+/-3dB <1GHz): 25cm x 30cm x 13cm (LxWxH) Septum height: 400mm Input impedance: 50 ohms / Input connector N includes feed-thru box 1 pc. 2x10A power line filter incl 1 pc. socket (Schuko) inside 1 pc. fiber optical feed-thru (3 couple) 1 pc. coax-feed-thru, type N 2 pc. coax-feed-thru, type SMA Weight: 120kg includes wheeled undercarriage Packing costs are not included. Assembly costs are not included.
|
GTEM 500
|
GTEM-Cell Frequency range: 100kHz to 20GHz Maximum power-input, W continuous/pulsed*:500*/1000 Dimensions: 3.00m x1.68m x 1.15m (L x W x H) Door size: 40cm x 40cm (WxH) Maximum EUT-Size: 40cm x 40cm x 30cm (L x W x H) Size of uniform area (+/-3dB <1GHz): 30cm x 35cm x 17cm (L x W x H) Septum height: 500mm Input impedance: 50 ohms / Input connector N includes feed-thru box 1 pc. 2x10A power line filter incl 1 pc. socket (Schuko) inside 1 pc. fiber optical feed-thru (3 couple) 1 pc. coax-feed-thru, type N 2 pcs. coax-feed-thru, type SMA 1 pc. unequipped technical panel Weight: 250kg includes wheeled undercarriage Packing costs are not included. Assembly costs are not included.
|
GTEM 750
|
GTEM-Cell Frequency range: 100kHz to 20GHz Maximum power-input, W continuous/pulsed*:700*/1500 Dimensions: 4.0m x 2.20m x 1.50m (L x W x H) Door size: 60cm x 60cm (W x H) Maximum EUT-Size: 60cm x 60cm x 50cm (L x W x H) Size of uniform area (+/-3dB <1GHz): 45cm x 45cm x 25cm (L x W x H) Septum height: 750mm Input impedance: 50 ohms / input connector N includes feed-thru box 1 pc. 2x10A power line filter incl 1 pc. Socket (Schuko) inside 1 pc. fiber optical feed-thru (3 couple) 1 pc. coax-feed-thru, type N 2 pcs. coax-feed-thru, type SMA 2 pcs. unequipped technical panels includes wheeled undercarriage Weight: 400kg Packing costs are not included. Assembly costs are not included.
|
GTEM 1000
|
GTEM-Cell Frequency range: 100kHz to 20GHz Maximum power input, W continuous/*pulsed:700W*/ 1500W Dimensions: 5.00m x 2.71m x 1.88m (L x W x H) Door size: 80cm x 80cm (W x H) Maximum EUT-Size: 75cm x 75cm x 70cm (L x W x H) Size of uniform area (+/-3dB <1GHz): 60cm x 60cm x 30cm (L x W x H) Septum height: 1.000mm Input impedance: 50 ohms / input connector N includes feed-thru box 1 pc. 2x10A power line filter incl 1 pc. Socket (Schuko) inside 1 pc. fiber optical feed-thru (3 couple) 1 pc. Coax-feed-thru, type «N» 2 pcs. Coax-feed-thru, type «SMA» 2 pcs. unequipped technical panels includes wheeled undercarriage Weight: ca. 700kg Packing costs are not included. Assembly costs are not included.
|
GTEM 1250
|
EMC GTEM 1250 Hot galvanized steel . max. Power 1500W continuous*, 2500peack power, 7/16 input connector, 1Pcs. Feed-throu for 1 couple fibers optics, N.3 N-N feed-throu, 16A mono-phase EMI Line filter, IEC 16A main line socket.10A AC/DC secondary filter, Door size: 80x110cm., 65Cm Pyramidal absorbers . Dimensions: 610×306x252cm.. Weight: 1200Kg Packing costs are not included. Assembly costs are not included.
|
GTEM 1500
|
GTEM-Cell Frequency range: 100kHz to 20GHz Maximum power-input, W continuous/*pulsed:850/1300* Dimensions: 7.10m x 3.81m x 2.50m (L x W x H) Door size: 0.80m x 1.20m (W x H) Maximum EUT-Size: (L x W x H) 1.20m x 1.20m x 1.00m Size of uniform area (+/-3dB <1GHz): 1.00m x 1.00m x 0.50m Septum height: 1.500mm Input impedance: 50 ohms / input connector N includes feed-thru box 1 pc. 2x10A power line filter incl 1 pc. socket (Schuko) inside 1 pc. fiber optical feed-thru (3 couple) 1 pc. coax-feed-thru, type N 2 pcs. coax-feed-thru, type SMA 1 pc. unequipped technical panel includes wheeled undercarriage Weight: 1000kg Packing costs are not included. Assembly costs are not included.
|
GTEM 1750
|
GTEM-Cell Frequency range: 100kHz to 20GHz Maximum power-input, W continuous/*pulsed:900/1400* Dimensions: 8.10m x 4.30m x 2.80m (L x W x H) Door size: 0.80m x 1.30m (W x H) Maximum EUT-Size: (L x W x H) 1.40m x 1.40m x 1.15m Size of uniform area (+/-3dB <1GHz): 1.25m x 1.25m x 0.58m Septum height: 1.750mm Input impedance: 50 ohms / input connector N includes feed-thru box 1 pc. 2x10A power line filter incl 1 pc. socket (Schuko) inside 1 pc. fiber optical feed-thru (3 couple) 1 pc. coax-feed-thru, type N 2 pcs. coax-feed-thru, type SMA 2 pcs. unequipped technical panels includes wheeled undercarriage Weight: 1300kg Packing costs are not included. Assembly costs are not included.
|
GTEM 2000
|
GTEM-Cell Frequency range: 100kHz to 20GHz Maximum power-input, W continuous/*pulsed: 1000/1600* Dimensions: 9.10m x 4.84m x 3.14m (L x W x H) Door size: 0.80m x 1.60m (W x H) Maximum EUT-Size: (L x W x H)1,75m x 1,75m x 1,30m Size of uniform area (+/-3dB <1GHz): 1.50m x 1.50m x 0.65m Septum height: 2.000mm Input impedance: 50 ohms / input connector N includes feed-thru box 1 pc. 2x10A power line filter incl 1 pc. socket (Schuko) inside 1 pc. fiber optical feed-thru (3 couple) 1 pc. coax-feed-thru, type N 2 pcs. coax-feed-thru, type SMA 2 pcs. unequipped technical panels includes wheeled undercarriage Weight: 1650kg Packing costs are not included. Assembly costs are not included.
|
GTEM 2500
|
GTEM Cell Input connector: N, Nominal impedance: 50, Frequency range: 1MHz-20GHz, Typical VSWR (medium value): 1:1.2, Typical VSWR at critical frequency: <1:1.6 , Max Input power, W continuous/*pulsed: 1000/2Kw, Mains connectors: Fix/CEE , Main Switch 16A magneto-thermal, Input Socket IEC plug 16Aac (Single phase + ground), «Output Socket Schuko tape 16Aac (Single phase +,ground) for EUT», Ground connection M6, AC mains filter 16A 250V /2 wires +ground , AC/DC filter 6A/2 wires 250V, Wave guide for fibre optic leads (3 couple), Media RF feed-thru N type connector: QTY 1, Media RF feed-thru SMA type connector: QTY 2, Window in door: 24Wx14.5H cm Diam., Technical panel pre-drilled for options, Empty Technical panels: QTY 2 Outer 1110Lx586Wx383H cm, Door W160x160H cm, Weight 2500 Kg. Approx., Max. test volume: 215Lx215Wx160H cm, Defined test Vol. +/-3dB <1000MHz (83.5Lx83.5Wx83.5H cm), Septum height: 2500mm
|
GTEM ACCESSORIES
|
|
GTEM-B01
|
EIA 7/8” Flange input connector (up to 3GHz)
|
GTEM-B02
|
7/16” Input connector (up to 3GHz)
|
GTEM-B03
|
Hi Power terminations 1KW up to 3GHz
|
GTEM-B04
|
Hi Power terminations 1,6KW up to 3GHz
|
GTEM-B05
|
Channels for fiber optical feed-thru (additional 3 pairs)
|
GTEM-B05F
|
Channels for fiber optic leads (additional 6 pairs)
|
GTEM-B06
|
Additional RF feed-thru connector N type
|
GTEM-B07
|
Additional RF feed-thru connector SMA type
|
GTEM-B08
|
Additional socket for EUT (IEC or Schuko)
|
GTEM-B09
|
Indoor lighting (Halogen lamp 50W)
|
GTEM-B09L3
|
Indoor lighting (LED lamp 4W)
|
GTEM-B09L20
|
Indoor lighting (LED lamp 30W)+shielded mesh screen
|
GTEM-B10-30
|
AC filter 30A/3wire (2PH+ Ground)
|
GTEM-B11-16
|
AC filter 16A/5wire (3PH+N+ Ground)
|
GTEM-B11-25
|
AC filter 25A/5wire (3PH+N+Ground)
|
GTEM-B11-30
|
AC filter 30A/5 wires (3PH+N+Ground)
|
GTEM-B11-64
|
AC filter 64A/5 wires (3PH+N+Ground)
|
GTEM-B21-300
|
I/O AC-DC feed-through 300A 440V
|
GTEM-B21
|
I/O AC-DC Custom filter box up to XX Channels
|
GTEM-B13
|
Electrical safety inter-lock
|
GTEM-B25
|
OPTION: GTEM-B25 9-poles DB9 signal EMI filter (1000pF) – signal filter 4 lines 28VDC, 1Amps/line
|
GTEM-B14
|
25-poles DB25 signal EMI filter (1000pF)
|
GTEM-B26-B32
|
RJ45 (RJ11) feed-thru connector
|
GTEM-B33
|
USB feed-thru connector
|
GTEM-B23
|
Vertical positioning, turn of the door position, plastic table over pyramidal absorbers
|
GTEM-B15-S
|
Secondary door next to input (Clear entry 40x40cm)
|
GTEM-B15-M
|
Secondary door next to input (Clear entry 60x60cm)
|
GTEM-B15-B
|
Secondary door next to input (Clear entry 80x80cm)
|
GTEM-B16
|
Window in door (Clear Diam. 200mm.)
|
GTEM-B17
|
Gas / Water feed through plates
|
GTEM-B18
|
Honeycomb panel
|
GTEM-B19
|
Fans kit for GTEM on technical panel
|
GTEM-B28
|
N.4 Fans kit channel for Heath sink .
|
GTEM-B027
|
Empty technical panel (Diam. 200mm.)
|
GTEM-B027C
|
Empty technical panel pre-cut on demand
|
GTEM-B20
|
Door for SAE J1752/3 test fixture
|
GTEM-B20/*
|
Option SAE 1752/3, IEC 62132-2 and IEC 61967-2
|
GTEM-B21
|
Undercarriage with swively wheels and brakes
|
GTEM-B40
|
Video camera system
|
GTEM-B40S
|
Shielded glass flange for external video camera vision
|
Trolley
|
Trolley with swivel caster and brake for TEM 1250
|
Illumination
|
Illumination kit, 20W Led light. Included
|
Window
|
Shielded window on the door. Diam. 22cm. Included
|
GTEM Shipping Crates
|
|
GTEM 250 S.C.
|
GTEM 250 Shipping Crate
|
GTEM 400 S.C.
|
GTEM 400 Shipping Crate
|
GTEM 500 S.C.
|
GTEM 500 Shipping Crate
|
GTEM 750 S.C.
|
GTEM 750 Shipping Crate
|
GTEM 1000 S.C.
|
GTEM 1000 Shipping Crate
|
GTEM 1250 S.C.
|
GTEM 1250 Shipping Crate
|
GTEM 1500 S.C.
|
GTEM 1500 Shipping Crate
|
GTEM 1750 S.C.
|
GTEM 1750 Shipping Crate
|
GTEM 2000 S.C.
|
GTEM 2000 Shipping Crate
|
GTEM Installation
|
|
GTEM 400 Assembly
|
2 days x two people. Travel and accommodations not included
|
GTEM 500 Assembly
|
3 days x two people. Travel and accommodations not included
|
GTEM 750 Assembly
|
5 days x two people. Travel and accommodations not included
|
GTEM 1000 Assembly
|
6 days x two people, and 1 local helper. Travel and accommodations not included
|
GTEM 1250 Assembly
|
8 days x two people and 1 local helper. Travel and accommodations not included
|
GTEM 1250 Assembly
|
Installation: 1 week, 2 people ( air compressor at your charge), Air flight Trip, accomodation included
|
GTEM 1500 Assembly
|
9 days x two people and 1 local helper. Travel and accommodations not included
|
GTEM 1750 Assembly
|
10 days x two people and 1 local helper. Travel and accommodations not included
|
GTEM 2000 Assembly
|
12 days x two people and 1 local helper. Travel and accommodations not included
|
TEM-CELLS
|
|
TEM 200
|
TEM-Cell, type TEM 200 Frequency-range: DC – 200MHz Height under coupling plate: 30cm Dimensions (LxWxH): 130x70x62cm Maximum input power: 1.6kW long term Field for a 25W amplifier: 118V/m Impedance: 50 ohm VSWR: <1.1 Return Loss: >25dB Connector type: N Weight: Approx. 29Kg Options: Signal and power supply filter *Can be equipped with a test setup for IC or PCB acc. to SAE J1752-3
|
TEM 500
|
TEM-Cell, type TEM 500 Frequency-range: DC – 500MHz Height under coupling plate: 10cm Dimensions (LxWxH): 60x30x22cm Maximum input power: 1kW long term Field for a 25W amplifier: 350V/m Impedance: 50 ohm VSWR: <1.1 Return Loss: >25dB Connector type: N Weight: Approx. 20Kg Options: Signal and power supply filter *Can be equipped with a test setup for IC or PCB acc. to SAE J1752-3
|
TEM 1000
|
TEM-Cell, type TEM 1000 Frequency-range: DC – 1GHz Height under coupling plate: 7.3cm Dimensions (LxWxH): 54x45x18cm Maximum input power: 750W long term Field for a 25W amplifier: 475V/m Impedance: 50 ohm VSWR: <1.2 Return Loss: >20dB Connector type: N Weight: Approx. 4.8Kg Options: Signal and power supply filter *Can be equipped with a test setup for IC or PCB acc. to SAE J1752-3
|
TEM 3000
|
TEM-Cell, type TEM 3000 Frequency-range: DC – 3GHz Height under coupling plate: 2.35cm Dimensions (LxWxH): 15x8x6cm Maximum input power: 400W long term Field for a 25W amplifier: 1.4V/m Impedance: 50 ohm VSWR: <1.2 Return Loss: >20dB Connector type: N or TNC, SMA Weight: Approx. 1.6Kg Options: Signal and power supply filter *Can be equipped with a test setup for IC or PCB acc. to SAE J1752-3
|
OPEN O-TEM-CELLS
|
|
O-TEM 200
|
Frequency range: DC-220MHz Height under plate: 33.3cm Max. input power: 1.5kW Maximum field: 800 V/m Field for a 25 amplifier: 105 V/m Dimensions (LxWxH): 180x160x73cm Weight: 55kg Field precision: ± 5% Connector: type N 50 Ω Cell impedance: 50 Ω Wave impedance: 377 Ω VSWR: <1.2(<1.9 for the O-TEM3000) Options: Signal and power supply filters, Dummy Loads *Can be equipped with a test setup for IC or PCB acc. to SAE J1752-3
|
0-TEM 500
|
Frequency range: DC-500MHz Height under plate: 14.7cm Max. input power: 1kW Maximum field: 1.5 kV/m Field for a 25 amplifier: 215 V/m Dimensions (LxWxH): 97x81x32cm Weight: 12kg Field precision: ± 5% Connector: type N 50 Ω Cell impedance: 50 Ω Wave impedance: 377 Ω VSWR: <1.2(<1.9 for the O-TEM3000) Options: Signal and power supply filters, Dummy Loads *Can be equipped with a test setup for IC or PCB acc. to SAE J1752-3
|
O-TEM 1000
|
Frequency range: DC-1GHz Height under plate: 7.3cm Max. input power: 750W Maximum field: 2.6 kV/m Field for a 25 amplifier: 480 V/m Dimensions (LxWxH): 54x45x16.8cm Weight: 3.5kg Field precision: ± 5% Connector: type N 50 Ω Cell impedance: 50 Ω Wave impedance: 377 Ω VSWR: <1.2(<1.9 for the O-TEM3000) Options: Signal and power supply filters, Dummy Loads *Can be equipped with a test setup for IC or PCB acc. to SAE J1752-3
|
O-TEM 3000
|
Frequency range: DC-3GHz Height under plate: 2.5cm Max. input power: 400W Maximum field: 5.6 kV/m Field for a 25 amplifier: 1400 V/m Dimensions (LxWxH): 44x45x18x8cm Weight: 3kg Field precision: ± 5% Connector: type N 50 Ω Cell impedance: 50 Ω Wave impedance: 377 Ω VSWR: <1.2(<1.9 for the O-TEM3000) Options: Signal and power supply filters, Dummy Loads *Can be equipped with a test setup for IC or PCB acc. to SAE J1752-3
|
OPEN TEM-CELLS Options
|
|
TEM 200 Trolley
|
Trolley with swivel caster and brake for TEM 200
|
Customized Filter
|
|
Van Veen Triple Loop Antenna 10KHz-30MHz
|
|
EMC-TLA32-2m
|
2.6x2x2 Meter EMC-TLA32 Loop Antenna 9KHz-30MHz
|
EMC-TLA32-3m
|
3.8x3x3 Meter EMC-TLA32 Loop Antenna 9KHz-30MHz
|
STRIP LINES
|
|
SR50/1000
|
Strip line, type SR50/1000 Strip-line for immunity-tests acc. to DIN/ISO 11452-5, 50 Ohm – version. Frequency-range: DC to 1GHz Maximum input-power: 1000W (long term) Impedance: 50 Ohm (+/- < 5 Ohm) Wave impedance: 377 Ohm VSWR: better than 1,22 up to 1GHz Dimensions: 4300mm x 1500mm x 1050mm (LXWXH) Height of the table: 950mm Weight: approx. 140kg includes rotating metallic table. For storage the strip line can be divided in parts 2 x (2150mm x 850mm x 1650mm). The packaging costs of the strip line in a wooden
|
SR 90/1000
|
Strip-line Strip-line for immunity-tests acc. to DIN/ISO 11452-5, 90 Ohm – version. Frequency-range: DC to 1GHz Maximum input-power: 100W (long term); (>100W with impedance adapter) Impedance: 90 Ohm (+4/ -6 Ohm) Wave impedance: 377 Ohm VSWR: better than 1,92 up to 1GHz Dimensions: 3500mm x 900mm x 1000mm (LXWXH) Height of the table: 850mm Weight: approx. 90kg includes Rotating metallic table. Optional: 50 to 90 Ohm adapter The packaging costs of the strip line in a wooden box is included
|