DANA SRL Power Supplies
Dana Linear Amplifier
• Linear Amplifier - DLA SERIES
Dana Elecrtronic Loads
• Linear Electronic Loads – DSO Series
• Linear Electronic Loads 0 Volt – DSOT Series
Dana Linear Electronic Switches
• Electronic Switches
Dana Linear Generators for Rail and Trams
• Linear Generators
Dana Digital Interfaces
• Digital Interfaces
Dana Continuous Current Generators
• Linear Continuous Current Generators – DAC Series
Dana Double Regulation Continuous
• Double Regulation Continuous Current Generators – DOC Series
Dana Power Sources
• AC/DC Power Sources – MPS Series
Dana Linear Power Supplies
• Linear Power Supplies
• Linear AC/DC Power Supplies – DA Series
• Linear AC/DC Power Supplies for Photo-voltaic Inverter Testing
• Linear 1000 Vdc Linear Power Supply – DAX-1000• Linear AC/DC Bipolar 2 Quadrant Power Supplies – D2A Series
• Linear AC/DC Bipolar 4 Quadrant Power Supplies – D4A & D4AA Series
• Linear AC/DC Multi Output Power Supplies – DP Series
• Linear AC/DC Bipolar 2 Opposite Quadrant Power Supplies – D2AC Series
• Linear Power Supply for Superconducting Coils
• Start Engine Power Supplies – DAS Series
Dana Double Regulation Power Supplies
• Double Regulation Power Supplies – DO Series
• Double Regulation 2 Quadrant Power Supplies – D2O Series
• Double Regulation Bipolar Opposite 2 Quadrant Power Supplies – D2OC Series
Dana Thystor Regulation Supplies
• Thyristors Regulation AC/DC Power Supplies – DE Series
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
DANA-DLA SERIES OF LINEAR AMPLIFIERS
TECHNICAL DATA
Mains Input
115 or 230 or 400 Vac ± 10% 50-60 Hz
Line regulation
better than 50 ppm of rated output V max for the allowed input variation
Load regulation for constant V
from no load to full load better than 50 ppm of rated output V
Load regulation for constant I
better than 100 ppm of I max from “0” to V max .
Overload Protection (OL)
Overload alarm in case of current output exceeding rated current with “OL” led
Short circuit Protection
Electronic controlled which immediately disable the output
Display “LCD”
Displays the peak values
Remote programming and feed-back (GPAC)
Opto-insulated analog signal 0÷10Vdc
Linearity better than 0.3% Drift better than 1.5mV/°C
Stability
after 20 minutes of preheating, better than 2 mV/°C for 24
Hours at 25°C
Temperature coefficient
lower 50 ppm/°C in “voltage mode”;
lower 100 ppm/°C in “current mode”
Ambient temperature
work 0÷40°C
storage -10÷75°C
Cooling
forced air
DANA Linear Amplifier – DLA Series
TECHNICAL DATA INTERNAL GENERATOR
Output Voltage
Adjustable by keyboard from zero up to max rated voltage with resolution of 0,1 V (f.s. of 50V) and 1V (f.s. over 50V). Through remote command GPAC, it has a resolution of 0,01V
Output Current
Adjustable by keyboard from zero up to max rated current with resolution of 0,1A with f.s. of 10A and of 1A with f.s. over 10A. With GPAC, it has resolution of 0,01A
Output Frequency
Adjustable by keyboard from 0 up to 400 Hz (if you set “000” is available the DC output)
Special frequency 16.66 Hz
It is adjustable by code n° “1000”
Distortion in AC mode
better than 0,5%
Ripple and noise (DC)
lower 10 ppm (rms) of rated output V, measured in V mode
TECHNICAL DATA – AMPLIFIER
Output Voltage
It can be programmed through external signal by BNC connector “EXT GEN” up to max rated voltage value
Output Current
It can be programmed through external signal by BNC connector “EXT GEN” up to the max rated current value
Output Frequency
see SLEW RATE diagram
Distortion
With AC output: 0,3% more than distortion of external generator
Ripple and noise (DC)
With DC output: 50 ppm of the rated Voltage more than max ripple of external generator
FRONT PANEL CONTROLS
PROGRAMMING PUSH-BUTTONS
ON
Stand-by push button. It works for generator section and for amplifier section with a status LED for each one
V-A
To select the amplifier working mode (current amplifier –
voltage amplifier). The selection is indicated by the LED lit.
“X”
push-button available for any additional functions on customer’s request. This command is repeated on the connector located on back panel and a LED shows the push button state
Mode
To select the working “Mode” as generator press on “Local” and GPAC – RS232 or as amplifier using EXT GEN function.
All functions are shown by switch-on of their “LED”
EXT. GEN – IN (BNC) Connector
Signal input (± 10 Vp) to be amplified within the limits of rated date – opto-insulated connector
Monitoring output connector 0 – 10 V
Output
Output plugs to use up to 5A of current
LCD
Show the set values when the DLS is on stand-by
Numerical Keyboard
Parameter output’s configuration in generator mode
BACK-PANEL CONTROLS
DIN Plug
For mains input 230 Vac up to 1200 VA; in alternative cable for 3-phase mains input
GPAC Connector
With signals 0 ÷ 10 V you can manage the remote mode or the output voltage and current regulation and by a TTL signal (0 / 5 V) ON condition or stand-by. It provides V and I feedback through 0 ÷
10 V signal.
All available signals are opto-insulated.
Connector X – Y:
It allows command duplication that it can be activated by push buttons X and Y allowing use by remote mode
Digital interface connectors
Output Plugs
They are available in models with output current over 6 A
DANA Linear Amplifier – DLA Series Output Values of different configurations
DANA Linear Amplifier – DLA Series Output Values of different configurations
DANA Linear Amplifier – DLA Series Slew Rate Limitation Bandwidth
GENERAL FEATURES
The linear amplifier for industrial purposes “DLA” is a very versatile device since it can amplify signals ranging from +10 V to –10V with a reaction time up to 8 V/µs on output. Featuring a voltage limiter and a current limiter, it can work both as current amplifier and as voltage amplifier. Application range is wide, including to amplify noises to be superimposed on EUT in order to evaluate their immunity against some mains noises.
For this purpose we show some diagrams being feasible with our amplifier as application examples.