    Seibersdorf Laboratories Free Space VSWR Validation
    Measurement Description

    Seibersdorf Laboratories Site VSWR Measurement
    The Free Space VSWR validation is done according to J.S. Hollis, T.J. Lyon, L. Clayton: “Microwave Antenna Measurement”, Scientific-Atlanta Inc., Atlanta, Georgia, USA, July 1970.

    In order to evaluate extraneous energy from several locations in the chamber, scans in transversal and longitudinal directions to the chamber axis are performed at (400 MHz), 800 MHz, 836 MHz, 1 GHz, 1.5 GHz, 1.88 GHz, 2.4 GHz, 6 GHz, 10 GHz, 12 GHz and 18 GHz in a test volume of 0.5 m (or 1 m) diameter in one height (max. 2 m). Each scan is performed in horizontal and vertical polarization with a different bore sight angle of the antenna to the measurement axis. This angle is changed in 15° steps to cover a range of 180°.

    This measurement is only possible with all the test equipment rented from Seibersdorf.

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Seibersdorf Laboratories Accredited re Calibration Service for EMC Test Sites Data Sheet

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Seibersdorf Laboratories RF Engineering Accredited Site Validation Data Sheet

     

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Seibersdorf Laboratories RF Site Validation Data Sheet