SEIBERSDORF PRODUCTS
Antennas
• PLA-R Precision Loop Antenna Receive
• PLA-SET Precision Loop Antenna Set For Site Validation
• POD 16 And POD 618 Precision Omnidirectional Dipoles Antennas
• PRD-Precision Reference Dipole
• PCD 3100 Precision Conical Dipole
• PCD 8250 – Precision Conical Dipole
Antenna Sets
• MS1 - Site VSWR Set
• MS2 - POD Antenna Set
• MS3 - MS1 Site VSWR Set without CalStan Software
• MS4 - Site VSWR Set - Automatic
• MS5 - PLA-Set for NSA validation
Antenna Site VSWR Positioners
CalStan 11.0 – RF Measurement Software
Comb Generators RefRad
Site Validation Services
• Absorber Return Loss - 200 MHz - 18 GHz
• ALSE – Absorber Lined Shielded Enclosure Measurements
• Ambient Noise Measurement
• Antenna Calibration Test Site Validation CISPR 16-1-5 30 MHz - 1 GHz
• Automotive Component Test Site Validation CISPR 25 150 KHz - 3 GHz
• Chamber FActor CENELEC R210-003 30 MHz - 1 GHz
• CTIA Ripple Test for Mobile Station 722 MHz - 2132.5 MHz
• CTIA Validation
• Field Uniformity Measurement
• Freespace VSWR Measurements
• NSA – Normalized Site Attenuation
• Shielding Effectiveness Measurement
• Site VSWR Measurement
• Table Influence
• Transmission Loss 1 Ghz - 40 Ghz
SEIBERSDORF LABORATORIES
Seibersdorf Laboratories Company
Seibersdorf Laboratories Data Sheets
Seibersdorf Laboratories Product List
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
Site Validation
Site Validation – Seibersdorf is the specialist
The testing and performance evaluation of EMC test sites requires precision field-strength measurements. Seibersdorf is the European market leader in this business.
We offer these measurements as accredited laboratory. Since 1997 we are also present on the Asian market. Due to intensive investigation in this field during the recent years many results have been adopted in international standards (e.g. CISPR 16 series).
The resulting know-how lead is applied in the course of the services regarding:
Standard Calibration:
· · ALSE – Absorber Lined Shielded Enclosure Measurements
· · Ambient Noise Measurements
· · Field Uniformity Measurements
· · NSA – Normalized Site Attenuation
· · Shielding Effectiveness Measurement
· · Site VSWR Measurement
Special Calibration:
· · CTIA Validation
· · Freespace VSWR Measurement
· · Table Influence
Calibration does not last for ever
Test sites have to be seen as a measurement device and therefore have to be calibrated regularly even if there are no changes in the construction since the last evaluation.
Seibersdorf Labor GmbH as market leader for the manufacturer independent validation of EMC test sites offers Accredited Re-Calibration for the regular recalibration of EMC test sites.
The aim of this service is to provide the traceable calibration of the EMC test site as required by ISO 17025 for accredited test houses.
Seibersdorf Laboratories Accredited re Calibration Service for EMC Test Sites Data Sheet
Seibersdorf Laboratories RF Engineering Accredited Site Validation Data Sheet