SEIBERSDORF PRODUCTS
Antennas
• PLA-R Precision Loop Antenna Receive
• PLA-SET Precision Loop Antenna Set For Site Validation
• POD 16 And POD 618 Precision Omnidirectional Dipoles Antennas
• PRD-Precision Reference Dipole
• PCD 3100 Precision Conical Dipole
• PCD 8250 – Precision Conical Dipole
Antenna Sets
• MS1 - Site VSWR Set
• MS2 - POD Antenna Set
• MS3 - MS1 Site VSWR Set without CalStan Software
• MS4 - Site VSWR Set - Automatic
• MS5 - PLA-Set for NSA validation
Antenna Site VSWR Positioners
CalStan 11.0 – RF Measurement Software
Comb Generators RefRad
Site Validation Services
• Absorber Return Loss - 200 MHz - 18 GHz
• ALSE – Absorber Lined Shielded Enclosure Measurements
• Ambient Noise Measurement
• Antenna Calibration Test Site Validation CISPR 16-1-5 30 MHz - 1 GHz
• Automotive Component Test Site Validation CISPR 25 150 KHz - 3 GHz
• Chamber FActor CENELEC R210-003 30 MHz - 1 GHz
• CTIA Ripple Test for Mobile Station 722 MHz - 2132.5 MHz
• CTIA Validation
• Field Uniformity Measurement
• Freespace VSWR Measurements
• NSA – Normalized Site Attenuation
• Shielding Effectiveness Measurement
• Site VSWR Measurement
• Table Influence
• Transmission Loss 1 Ghz - 40 Ghz
SEIBERSDORF LABORATORIES
Seibersdorf Laboratories Company
Seibersdorf Laboratories Data Sheets
Seibersdorf Laboratories Product List
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
Validation Of Table Influence
Seibersdorf Site Validation Services
Validation of Table Influence Services
Measurement Description
The Table Influence (TI) is measured according to CISPR 16-1-4 in the frequency range 200 MHz – 18 GHz.
A small biconical transmit antenna and/or small omni directional antenna is placed over the set-up table in horizontal polarization and the received field strength is recorded in the nominal test distance, with is used for the radiated disturbance measurements. The table is removed and the field strength is recorded again. The uncertainty contribution to be used in the RE-testing uncertainty budget is calculated from these two field strength readings.
This evaluation shall be performed on any set-up table with a height of more than 0.15 m.
For measurement with the customer’s equipment, we need a calibrated test receiver or spectrum analyzer with GPIB interface, antennas, cabling and antenna mast with GPIB.
Seibersdorf Laboratories Accredited re Calibration Service for EMC Test Sites Data Sheet