EUROFINS YORK PRODUCTS
• Comb Generator Emitter (CGE01)
• Comb Generator Emitter (CGE05)
• Comb Generator Emitter (CGE06)
Comparison Noise Generators
• Comparison Noise Emitter V (CNE V)
• Comparison Noise Emitter V+ (CNE V+)
• Comparison Noise Emitter VI (CNE VI)
Harmonic and Flicker Generator
• Harmonic and Flicker Generator (HFG01KIT01)
• Harmonic and Flicker Generator (HFG02KIT01)
York Reference Sources (YRS)
• York Reference Source (YRS01) Kits 01 & 02
• York Reference Source (YRS02) Kits 01 and 02
• York Reference Source (YRS03) Kits 01 and 02
• York Reference Source YRS Combination Kit
Company Overview
Eurofins York Data Sheets
Eurofins York Product List
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
EUROFINS YORK - Small Active Receive Antenna
Eurofins York ARA01KIT01 Small Active Receive Antenna
A small active receive antenna is the ideal antenna for EMC testing in restricted spaces
1. Small antenna size is particularly ideal for use in anechoic chambers
2. High sensitivity, better than typical conventional antennas.
3. Can be used with any EMC analyzer
The Eurofins York ARA01KIT01 Small Active Receive Antenna has been designed as a compact emissions antenna. The small size makes it particularly suitable for use in anechoic chambers, however it can also be used on an Open Area Test Site (OATS).
The unit is powered from a single PP3 battery. A green LED indicates that the antenna is active, a red LED indicates that the battery is low and should be recharged or replaced. There is also an external DC option where the DC is supplied via the RF cable.
There are two sets of Dipole Antenna Elements (DAE) which can be used. The unit is supplied with one set as standard (DAE01). For higher sensitivity at the low frequencies DAE02 should be used.
Full antenna factor data is included with each ARA.
The Active Receive Antenna ARA01KIT01 from Eurofins York has been designed as a pre-compliance emissions antenna, with a performance comparable to a conventional wide band passive antenna such as the Bilog™.
Features
– Stable performance
– Repeatable measurements
-
- – Bilog™ equivalent performance
-
– Accurate results
- – 30MHz to 1GHz range
-
– Most commonly used measurement range
- – Compact and Portable
-
– Measurements in confined spaces
-
– Measurements where equipment must be hand carried
-
– Field testing
- – Battery powered
-
– Mains power not required for measurements
- – Low cost
-
– Affordable measurement systems
APPLICATIONS
- Radiated emissions measurements in a confined area
- Low cost alternative to passive wide band antenna
- Portable measurement systems
SPECIFICATIONS
Specifications | |
---|---|
Frequency range | 30MHz (200MHz optimum) to 1GHz using DAE01 100mm long antenna elements |
30MHz to 300MHz (optimum) using DAE02 290mm long antenna elements | |
Output connector | 50Ω BNC socket |
Output VSWR | 1.5:1 |
Dynamic range | 90dB |
1dB compression | 15.4dBm ≡ 35.5mW ≡ 1.33V (in a 50Ω system) |
Antenna factor | See graph below |
Temperature stability | 5°C to 45°C: <1 dB |
Time stability | Typically <1 dB over a 12 month period |
Dimensions | 34mm × 34mm × 150mm (168mm including connector) excluding dipole elements |
Weight | 0.39kg (including battery) |
Power supply | 1 × 9V battery (PP3 or equivalent) or 9V-12V 70mA external power supply (not supplied) |
Operating time | 6.5 hours typical with alkaline cells |
Indicators | Power on – green LED |
Battery low – red LED |
SATNDARD ORDER KITS
Part Number: ARA01KIT01
Description: Standard ARA01 active receive antenna kit with pair of 200MHz to 1GHz antennas
Parts Included:
– ARA01 Active receive antenna
– 2× DAE01 antenna elements
– CAL08 antenna factors
– Alkaline battery
ACCESORIES
Accessory | Part Nº | Description |
---|---|---|
Antennas | DAE01 | 200MHz to 1GHz (optimum) 100mm long antenna elements |
DAE02 | 30MHz to 300MHz (optimum) 290mm long antenna elements | |
Tripod Adapter | TRA01 | Tripod adapter with ARA01 mounting brackets |
OUTPUT MEASUREMENT RESULTS
Type | Order Nº | Description |
---|---|---|
Antenna Factor | CAL08 | 30MHz to 1GHz antenna factor derived from GTEM measurements against a known standard |
MANUFACTURERS CALIBRATIONS
CAL08 – 30MHz to 1GHz antenna factor derived from a known standard
TYPICAL OUTPUT MEASUREMENT RESULTS