EnglishPortugueseSpanish

Request a Quote / Contact Us!

    Manufacturer

    Part Number or Numbers

    EUROFINS YORK - Harmonic and Flicker Generator HFG02

    York EMC HFG02 Harmonics and Flicker Generator 01

    The new Harmonics & Flicker Generator (HFG02) is Eurofins York newest HFG product. It is a multi-function electronic load which has been designed with the purpose of verifying harmonic and flicker test equipment. It offers an easy and reliable way to externally check the performance of the measurement system to the EN/IEC 61000-3-2 harmonics and IEC/EN 61000-3-3 flicker standards.

    A reference source is particularly useful where there is little intuitive sense of the expected response and the tests rely on software control and calculation to produce a result. The HFG02 provides a series of harmonic and flicker disturbances of a nominal but stable level. This allows the user to periodically verify their test equipment, helping maintain compliance with standards and laboratory quality procedures. Alternatively, due to its stability, it may be used as a transfer standard from a known calibrated test system.

    The HFG02 is a standalone device that connects directly to the test equipment and simulates it under test (EUT), generating known repeatable levels of harmonic and flicker disturbance.

    FEATURES

    Stable load simulation

    • Repeatable measurements for test system verification
    • Injects harmonics to EN61000-3-2 and flicker to EN61000-3-3

    – Evaluation of test systems specifically to EN standards

      • Harmonic test modes

      – Steady-state harmonic-rich load current, representing a fixed load

        • – Harmonic-rich load currents fluctuating between two load conditions
        • – Interharmonic load currents at 5 Hz and 10 Hz rates

      – Harmonic and interharmonic-rich load

      • Flicker test modes
        • – Fixed level of mains disturbance at 1 Hz rate
        • – Fixed level of mains disturbance at 8.33 Hz (50 Hz supply) or 8.6 Hz rates (60 Hz supply)
      • EUT modes

      – Simulates waveforms generated by several different types of equipment:

          • – – Half-wave rectifier
          • – – Analogue dimmer
          • – – Intermittent flicker
      • Compact and Portable

      – Comparisons between multi-site test environments

      • Dual supply operation
        • – Automatically detects 115 Vac and 230 Vac systems and adjusts its output to match
        • – Test supply voltage and frequency indication
      • Independent power supply
        • – Separate power supply to the HFG02 to avoid contamination of the test signals

      SPECIFICATIONS

      Test supply
      Voltage: 115 Vac (nominal), 230 Vac (nominal)
      Frequency: 50 Hz, 60 Hz
      Power: 500 W (maximum)

      Disturbances generated
      Harmonic current: Up to 40th harmonic: 50 Hz to 2 kHz (50 Hz), 60 Hz to 2.4 kHz (60 Hz) (see results graphs)

      Flicker disturbance: (see results tables)

      Test supply connector

      1.3 m captive lead with BS 1363 3-pin UK mains plug, for connection to test equipment. Adapters for EU and US style mains connectors included.

      Indicators

      Test supply voltage
      Test supply frequency
      Test enabled
      Alarm (thermal overload, system error) 

      HFG02 power supply – External power supply, 24 Vdc, 2 A maximum
      Power supply connector: 2.1 mm DC power socket
      Ext. PSU input rating: 100 – 240 Vac, 50-60 Hz, 50 W (maximum)

      Dimensions

      330 mm × 320 mm × 170 mm (not including test supply connector)
      Weight

      8 kg

       

      York EMC Services YES HFG02 EUT Modes

      York EMC Services YES HFG02 Fixed Harmonics Graph

      York EMC Services YES HFG02 fluctuating Harmonic Mode Graph

       

      York  EMC Services YES HFG02 Interharmonics Modes Graph

       

      York EMC Services YES HFG Fixed Harmonic Mode Graph

       

      Standard Order Kits

      Part Number

      Description

      Parts Included

      HFG02KIT01

      Standard HFG02 harmonics and flicker generator kit

      • HFG02 harmonic and flicker generator

      • CAL22 – standard test

       

      CAL22 Measurement of harmonic and flicker disturbance generated:

      • Harmonics -Measurement of load current according to EN 61000-3-2 in Fixed, Fluctuating and Interharmonic modes. Fundamental to 40th harmonic, 115 Vac/60 Hz and 230 Vac/50 Hz test supply.
      • Flicker – Measurement of short term flicker (Pst) according to EN 61000-3-3 with disturbance at 1 Hz and 8.33 Hz/8.6 Hz rates. 115 Vac/60 Hz and 230 Vac/50 Hz test supply.

       

      Shipping Container dimensions and weight informationShipping Container:

      62 x 52 x 42 cm