FRANKONIA PRODUCT LINE
Automotive Anechoic Chambers
• ACTC – Automotive Component Testing Chamber
• AVTC – Automotive Vehicle Testing Chamber
• RanLOS – OTA testing with RanLOS (Random Line-of-Sight)
• SAC-10V – Semi Anechoic 10m EMC Chamber dedicated to Vehicle Tests per ECE R10
• SAC-10Vx – Next generation multi-purpose Anechoic Chambers
• UCC – Ultra Compact Chamber
• Verteon Class – Multi-purpose Automotive Antenna Chamber
Commercial Anechoic Chambers
• CHC – Compact Hybrid Chamber
• CHC Plus – Pre-compliant 3m Compact EMC Chamber
• FAC-3 – Compact Fully Anechoic Chamber
• FAC-3 L – Fully Anechoic 3M EMC Chamber for floor-standing EUT’s
• SAC-3 / FAC-3 Transformer – Semi and Fully Anechoic 3m EMC Chamber transformable combination
• SAC-3 Plus – Semi Anechoic 3m EMC Chamber with dome-shape design
• SAC-5 Square Semi Anechoic 5m EMC Chamber with traditional square design
• SAC-10 Plus Triton Class with TRIPLE Axes Test – Anechoic chamber for 10.0 & 3.0 m measuring distance with triple axes test
• SAC-10/H Hybrid – Semi Anechoic 10m EMC Chamber with Hybrid Absorbers
• SAC-10/P – Pyramid Semi Anechoic 10m EMC Chamber with Long-pyramid P2400 Absorbers
• SAC-10 Plus – Anechoic Chambers for 10m measuring distance
• Shielded Room Modular and pre-fabricated Standard
Military Anechoic Chambers
• MIL-CHC – MIL Compact Hybrid Chamber
• MIL-STD Chamber – Military Testing Chamber for Vehicles and large EUT’s
• MIL-STD Chamber advanced – Military Testing Chamber for Vehicles and large EUT’s
Powertrain Solutions
• Battery & Charging Systems – Battery Testing Solution and High-Power Charging Solution
• Fixed Load Machine with EDTC – Fixed-shaft Load Machine per CISPR 25 with EDTC
• EMC-BlueBox with EDTC-BB
• MEDET Hidraulic Modular E-Drive Testing per CISPR 25 with EDTC
Security Chambers
• Cyber Security Chamber – Shielded Rooms for Cyber Security Tests
• Conversation & Meeting Chambers – Bugging-protected
• Reverberation Tent – For use inside existing EMC Chambers
Company Overview
Test Tables
Data Sheets & Manuals
Product List
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
FRANKONIA - CHC - Compact Hybrid Anechoic Chamber
FRANKONIA – CHC – Compact Hybrid Chamber, 3M TEST DISTANCE
Frankonia CHC – Pre-compliant 3m Compact EMC Chamber
Overview | Frankonia CHC – Compact Hybrid Chamber |
EMI | Pre-compliant |
EMS | IEC/EN 61000-4-3, full compliant |
Test distance | 3,0 m |
Volume | ø1,2 m |
Special | Compact immunity test chamber |
The CHC is Frankonia’s compact hybrid chamber solution at 3,0 m measuring distance with a Quiet Zone (QZ) of ø1,2 m. The CHC is an upgradable solution and can transform from a semi anechoic chamber configuration with ground plane to a fully anechoic chamber configuration with floor absorbers. It is an optimal solution for both pre-compliance emission tests and full compliance immunity tests at 3,0 m measuring distance.
The CHC can be delivered optionally as a semi-anechoic chamber (with ground plane) or as a fully anechoic chamber (floor absorbers on the whole floor surface).
For immunity tests, floor absorbers are required in each case between transmitting antenna and EUT and are therefore included in the standard delivery volume.
Typical Specifications
Chamber |
CHC |
CHC-L |
External dimension |
7.355 x 3.755 x 3.300 mm (LxWxH) |
8.255 x 3.755 x 3.300 mm (LxWxH) |
Quiet Zone |
ø1,2 m |
|
Measuring distances |
3,0 m |
|
Load capacity |
up to 2,0 tons; special turntable systems possible |
|
Frequency range |
9 kHz/ 30 MHz to 18 GHz (option 40 GHz) |
Typical Product Standards
Emission
• Pre-compliance from 30 MHz to 1 GHz
Immunity
• IEC/EN 61000-4-3
Typical Verification Standards
Emission
• CISPR 16-1-4
Immunity
• IEC/EN 61000-4-3
Performance:
SHIELDING EFFECTIVENESS (SE)
Acc. to EN 50147-1 from 10kHz to 18GHz the following values are guaranteed: see table paragraph 1
EMISSION – pre-compliance
According to CISPR 16-1-4
Test distance: 3,0m
Frequency range: 30MHz- 200MHz (pre-compliance)
Frequency range: 200MHz- 1GHz (compliance)
Quiet Zone: Ø1,2m (2m H)
IMMUNITY – pre-compliance
According to IEC/EN 61000-4-3/ ISO 11452-2
Test distance: 3,0m
Frequency range: 80MHz- 18GHz
Uniform area: 0,5m x 0,5m
Guaranteed FU: -0/+6dB for 12 of 16 test points (75%)
Outside shielding dimensions (LxWxH): 7,355 x 3,755 x 3,300m
Shielding and structure |
Quantity |
Unit |
Shielding modules PAN type |
1 |
Set |
Ceiling/ wall reinforcement |
1 |
Set |
Rubber membrane under the chamber for humidity protection |
1 |
Set |
Absorber ferrite tiles F006 | ||
Floor lined with F006 (7,2m²) for EMS (FU) | 1 | Set |
Walls and ceiling lined with F006 | 1 | Set |
Rail substructure for ferrite tile plates | 1 | Set |
Absorber Frankosorb® pyramids – fire class B2 DIN 4102/ DIN EN 13501-1 (2010-01) | ||
Floor with H600 B2 (7,2m²) for EMS (FU) |
1 |
Set |
Small wall behind the turntable lined with H450 B2 |
1 |
Set |
Side walls partially lined with H450 B2 (approx. half of the chamber) |
1 |
Set |
Ceiling partially lined with H450 B2 (approx. half of the chamber) |
1 |
Set |
Personal door type 2011 – External leaf painted RAL 9002 (light grey) |
||
SLD 10/20/M Personal door with clear opening 1013 x 2043mm with manual latching, prepared for receiving absorbers |
1 |
Pc |
Door stopper |
1 |
Pc |
Manual wooden ramp, load capacity 200kg |
1 |
Pc |
Penetration panels, feed throughs & connectors | ||
Penetration panel (PP) 400 x 400mm, including C-frame |
1 |
Pc |
N connector |
4 |
Pcs |
N+BNC adaptor |
4 |
Pcs |
FSMA connector |
4 |
Pcs |
Floor connection panels & connectors | ||
Connection panel (CP) 600 x 600mm – automatic with jacks |
2 |
Pcs |
N connector |
4 |
Pcs |
BNC connector |
4 |
Pcs |
FSMA connector |
4 |
Pcs |
Power filter and grounding point | ||
Insertion loss high performance filters: 100dB from 14kHz to 40GHz | ||
Power filter 2x6A – 250V AC – 50/60Hz for the chamber |
1 |
Pc |
Power filter 2x32A – 250V AC – 50/60Hz for the EUT |
1 |
Pc |
Electrical installation | ||
Electrical installation |
1 |
Set |
Lighting Halogen 230W |
4 |
Pcs |
Shielded access box to the electrical distribution box with access from inside |
1 |
Pc |
Electrical ducts in raised floor |
1 |
Set |
Socket: 1phase 60Hz 32A (US type) |
1 |
Pc |
Socket: Duplex single phase 16A (US type) |
3 |
Pcs |
Emergency lighting low noise with 3 lights and outside UPS with filter |
1 |
Set |
Honeycombs | ||
Honeycombs 400 x 400mm – 18GHz |
2 |
Pcs |
Floor | ||
Height: 150mm | ||
Raised floor modular standard up to 500 kg/m² with hot galvanized ground plane 2,0mm | 1 | Set |
Standard Equipment
· 1 access door, 1.013 x 2.043 mm
· 1 honeycomb insert for ventilation
· 1 mains filter 250 VAC, 2 x 16 A
· 1 penetration panel
· Feed-throughs: 4 x “N”, 4 x “BNC” and 1 x for fibre optics
· Electric installation
· Illumination
· Raised floor
· Absorber lining
Options
· 3 phase mains filter
· Signal and / or data line filter
· Fan · Antenna tripod
· Video and / or audio system
· Verification of the chamber
· Measuring equipment
· Other extras
fOR MORE DETAIL, PLEASE DOWNLOAD THE FOLLOWING PDF FILE
Frankonia CHC – Compact Hybrid Chamber, 3m test distance Data Sheet