FRANKONIA PRODUCT LINE
Automotive Anechoic Chambers
• ACTC – Automotive Component Testing Chamber
• AVTC – Automotive Vehicle Testing Chamber
• RanLOS – OTA testing with RanLOS (Random Line-of-Sight)
• SAC-10V – Semi Anechoic 10m EMC Chamber dedicated to Vehicle Tests per ECE R10
• SAC-10Vx – Next generation multi-purpose Anechoic Chambers
• UCC – Ultra Compact Chamber
• Verteon Class – Multi-purpose Automotive Antenna Chamber
Commercial Anechoic Chambers
• CHC – Compact Hybrid Chamber
• CHC Plus – Pre-compliant 3m Compact EMC Chamber
• FAC-3 – Compact Fully Anechoic Chamber
• FAC-3 L – Fully Anechoic 3M EMC Chamber for floor-standing EUT’s
• SAC-3 / FAC-3 Transformer – Semi and Fully Anechoic 3m EMC Chamber transformable combination
• SAC-3 Plus – Semi Anechoic 3m EMC Chamber with dome-shape design
• SAC-5 Square Semi Anechoic 5m EMC Chamber with traditional square design
• SAC-10 Plus Triton Class with TRIPLE Axes Test – Anechoic chamber for 10.0 & 3.0 m measuring distance with triple axes test
• SAC-10/H Hybrid – Semi Anechoic 10m EMC Chamber with Hybrid Absorbers
• SAC-10/P – Pyramid Semi Anechoic 10m EMC Chamber with Long-pyramid P2400 Absorbers
• SAC-10 Plus – Anechoic Chambers for 10m measuring distance
• Shielded Room Modular and pre-fabricated Standard
Military Anechoic Chambers
• MIL-CHC – MIL Compact Hybrid Chamber
• MIL-STD Chamber – Military Testing Chamber for Vehicles and large EUT’s
• MIL-STD Chamber advanced – Military Testing Chamber for Vehicles and large EUT’s
Powertrain Solutions
• Battery & Charging Systems – Battery Testing Solution and High-Power Charging Solution
• Fixed Load Machine with EDTC – Fixed-shaft Load Machine per CISPR 25 with EDTC
• EMC-BlueBox with EDTC-BB
• MEDET Hidraulic Modular E-Drive Testing per CISPR 25 with EDTC
Security Chambers
• Cyber Security Chamber – Shielded Rooms for Cyber Security Tests
• Conversation & Meeting Chambers – Bugging-protected
• Reverberation Tent – For use inside existing EMC Chambers
Company Overview
Test Tables
Data Sheets & Manuals
Product List
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
FRANKONIA - UCC - CHC PLUS - Compact Hybrid Chamber
Frankonia CHC Plus – Pre-compliant 3m Compact Hybrid EMC Chamber
Overview |
Frankonia CHC Plus |
EMI |
CISPR 16-1-4, Pre-compliant 30 MHz to 1 GHz |
EMS |
IEC/EN 61000-4-3, full compliant |
Test distance |
3,0m |
Volume |
ø1,2 m |
Special |
Compact immunity test chamber, full compliant for emission >1 GHz |
The CHC Plus is Frankonia’s version of the Compact Hybrid Chamber solution at 3,0m measuring distance with a Quiet Zone (QZ) of ø1,2m that meets the SVSWR verification. The CHC Plus is an upgradable solution and can transform from a semi anechoic chamber configuration with ground plane to a fully anechoic chamber configuration with floor absorbers. It is an optimal solution for both pre-compliance emission tests and full compliance immunity tests at 3,0m measuring distance.
Features
• Full compliant EMS
• Pre-compliant EMI solution from 30 MHz to 1 GHz (no height scan possible)
• Full compliant EMI solution from 1 GHz to 18 GHz (no height scan necessary)
• Cost effective solution for EMS measurements, paired with EMI measurements in the GHz range
• Compact chamber design with advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)
• Upgradable to FAC for free-space measurements
• Turnkey solution
Typical Product Standards
Emission
• Pre-compliant from 30 MHz to 1 GHz
• Full compliant from 1 GHz to 18 GHz
Immunity
• IEC/EN 61000-4-3
Performance & Compliance
• Pre-compliant emission (EMI) according to CISPR 16-1-4 from 30 MHz to 1 GHz
• Full compliant emission (EMI) according to CISPR 16-1-4 from 1 GHz to 18 GHz
• Full compliant immunity (EMS) according to IEC/EN 61000-4-3
• Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed