EnglishPortugueseSpanish
FRANKONIA PRODUCT LINE

Automotive Anechoic Chambers
• ACTC – Automotive Component Testing Chamber
• AVTC – Automotive Vehicle Testing Chamber
• RanLOS – OTA testing with RanLOS (Random Line-of-Sight)
• SAC-10V – Semi Anechoic 10m EMC Chamber dedicated to Vehicle Tests per ECE R10
• SAC-10Vx – Next generation multi-purpose Anechoic Chambers
• UCC – Ultra Compact Chamber
• Verteon Class – Multi-purpose Automotive Antenna Chamber
Commercial Anechoic Chambers
• CHC – Compact Hybrid Chamber
CHC Plus – Pre-compliant 3m Compact EMC Chamber
• FAC-3 – Compact Fully Anechoic Chamber
• FAC-3 L – Fully Anechoic 3M EMC Chamber for floor-standing EUT’s
• SAC-3 / FAC-3 Transformer – Semi and Fully Anechoic 3m EMC Chamber transformable combination
• SAC-3 Plus – Semi Anechoic 3m EMC Chamber with dome-shape design
• SAC-5 Square Semi Anechoic 5m EMC Chamber with traditional square design
• SAC-10 Plus Triton Class with TRIPLE Axes Test – Anechoic chamber for 10.0 & 3.0 m measuring distance with triple axes test
• SAC-10/H Hybrid – Semi Anechoic 10m EMC Chamber with Hybrid Absorbers
• SAC-10/P – Pyramid Semi Anechoic 10m EMC Chamber with Long-pyramid P2400 Absorbers
• SAC-10 Plus – Anechoic Chambers for 10m measuring distance
• Shielded Room Modular and pre-fabricated Standard
Military Anechoic Chambers
• MIL-CHC – MIL Compact Hybrid Chamber
• MIL-STD Chamber – Military Testing Chamber for Vehicles and large EUT’s
• MIL-STD Chamber advanced – Military Testing Chamber for Vehicles and large EUT’s
Powertrain Solutions
• Battery & Charging Systems – Battery Testing Solution and High-Power Charging Solution
• Fixed Load Machine with EDTC – Fixed-shaft Load Machine per CISPR 25 with EDTC
• EMC-BlueBox with EDTC-BB
• MEDET Hidraulic Modular E-Drive Testing per CISPR 25 with EDTC
Security Chambers
• Cyber Security Chamber – Shielded Rooms for Cyber Security Tests
• Conversation & Meeting Chambers – Bugging-protected
• Reverberation Tent – For use inside existing EMC Chambers

Company Overview
Test Tables
Data Sheets & Manuals
Product List

Request a Quote / Contact Us!

    Manufacturer

    Part Number or Numbers

    FRANKONIA - ACTC - MEDET HYDRAULIC SYSTEM WITH EDTC

    Frankonia Frankonia Hydraulic System with EDTC
    Frankonia MEDET Hydraulic System with EDTC

    MEDET Hydraulic Modular E-Drive Testing per CISPR 25 with EDTC

     

    Overview

    MEDET Hydraulic System with EDTC

    Compliance

    CISPR 25, ISO 11452

    System

    Fixed Load Machine (electrical driven)Hydraulic power provision to the EUT, from 70 kW up to 280 kW

    Features

    – Useable for motors, components, or in

    – Plug & Play System

    – Useable for motors and components

    – Flexible and efficient using a hydraulic system

    Volume

    Table setup

     

    Frankonia MEDET Hydraulic System with EDTC

    One of the biggest challenges in modern automotive development is the electrification of the powertrain. This implies the use of powerful drive motors as well as other auxiliary electrical drives. Besides the well-known setup with one electric traction motor replacing the combustion engine, other concepts such as wheel hub drives, or fully integrated axles are used. These highly integrated electrical axles consisting the axle itself, the electric drive motor, the gearbox and the differential, cause challenges in EMC testing.

     

    The MEDET system is one of the new power train setups using a hydraulic system. A power converter is outside the chamber and produces the oil pressure to the EUT power converter placed inside the chamber. The EDTC chamber solution is adapted for full compliant tests of automotive components according to CISPR 25 and ISO 11452.A permanent plug-in contact strip is installed between the absorbers to ensure the electrical connection of the test table to the shielding and includes the test table as required per to CISPR 25. The typical chamber is lined with ferrite absorbers and partially lined with Frankosorb®hybrid absorbers.

     

    Flexibility

    • The connection of the power unit adaption unit (inside EMC facility) with flexible hoses, provides more installation options.

    • Multiple EMC test facilities in parallel; one power unit can feed multiple EMC facilities.

    • EMC testing of electric axles can be carried out without any modification of the device under test.

     

    Scalability

    • The scalable setup of the MEDET system allows to adjust the size of the system perfectly to the customer’s need.

    • The power unit design can modular increased in 70 kW steps up to 280 kW.

     

    Dynamic

    • Low oscillating weight of the adaption unit at the EUT for a fast adjustment.

    • Protection of EUT and test setup by using torque shocks attenuations.

     

    Handling

    • Easy adaptation with the EUT module weighs less than 20 kg (with a 70kw power module) and can easily be installed with standardized mechanical fittings.

    • The connection to the power module with a quick coupling system.

    • The control of the complete test setup has been realized with an industrial touch panel and dedicated software. The basic adjustments before testing (torque mode, repetition mode) are quickly made.

    • The MEDET system allows all kinds of power flow (passive mode: test setup drives the EUT; active mode: EUT drives the test setup). Additionally, the system automatically synchronizes with the EUT.

     

    Typical Product and Verification Standards

    Emission

    • CISPR 25

    Immunity

    • ISO 11452

     

    Chamber Type

    EDTC with MEDET  

    External dimensions

    6.380 x 5.480 x 3.750 mm (LxWxH)

    Setup

    Table setup

    Power Range

    70 kw up to 280 kW

    Measuring distances

    1,0 m

    Load capacity

    up to 10,0 tons

    Frequency range

    9 kHz/ 150 kHz to 18 GHz (option 40 GHz)

     

    Performance & Compliance

    Full compliant emission (EMI) according to CISPR 25 Ed.4

    (ALSE verification acc. to the long-wire method recommended)

    Full compliant immunity (EMS) according to ISO 11452