    Com-Power Immunity System

    Conducted Immunity System (CIS) to Test According to IEC 61000-4-6. The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes an ACS series power amplifier, coupling/decoupling Network (CDN), directional coupler, 150Ω to 50Ω adapters, power attenuators, cables and [optional] CSAT software. These systems, when properly configured, are capable of testing your products to all levels given in IEC 61000-4-6 up to 230 MHz. You can choose from three systems. Follow the links below for detailed information, including a comprehensive datasheet listing system specs.

    The IEC-61000-4-6 requires that, when commercially available, an appropriate coupling/decoupling network (CDN) with the defined common mode impedance be used as the coupling device the conducted immunity test. Com-Power has a wide variety of CDNs. The system can be customized to include the specific CDN(s) for your application.

    Before you begin testing with the CDN, you will need to establish a calibrated drive levels corresponding to the test level to be applied. When used with compatible signal generator and spectrum analyzer, the CSAT test software can fully automate the calibration process, in addition to performing the actual test. These systems are capable of testing your products to the all levels given in IEC 61000-4-6 over the entire frequency range of the test, 150 kHz to 230 MHz. Notwithstanding the level setting calibration process, Com-Power CDNs are designed and calibrated to meet the latest CISPR 16 test standards.

    CIS-100 100 Watts Conducted Immunity System (High Power) 150 kHz to 230 MHz

    CIS-100 100 Watts Conducted Immunity System (High Power) 150 kHz to 230 MHz

    Conducted Immunity System (CIS) to Test According to IEC 61000-4-6. The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes ACS series power amplifier, Coupling Decoupling Network (CDN), directional couplers, attenuators, cables and CSAT software. These systems when properly configured are capable of testing your products to the all levels given in IEC 61000-4-6 up to 230 MHz. The two systems available and are given the table below. The IEC-61000-4-6 requires that an appropriate a coupling decoupling networks (CDN) with defined common mode impedance is used for testing conducted immunity. Com-Power has a wide variety of CDNs. The system can be customized include the CDNs to fit your application at the time of purchase. Before you begin testing with the CDN you will need to establish a calibrated drive levels corresponding to the test levels. When used with compatible signal generator and spectrum analyzer, the CSAT test software can fully automate this calibration and also perform the test. Com-Power CDNs are calibrated to meet the latest CISPR 16 test standards.

     

    Test System Includes:

    • · ACS-250-100 W Power Amplifier

    • · CDNs (to be determined at the time of purchase)

    • · ATTEN-6-100W

    • · ATTEN-30-100W

    • · DCU-1000-100W

    • · Cable set

    • · Appropriate CDN shorting adapters

    • · ADA-515 150 Ohm to 50 Ohm adapters

    • · 50 Ohm terminator

    · COSAT/CSAT Software (optional) at additional cost.

     

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power CIS-100 Conducted Immunity System100 Watts Data Sheet

    CIS-50 Conducted Immunity Test System 50 Watts, 150 kHz to 230 MHz

    CIS-50 Conducted Immunity Test System 50 Watts, 150 kHz to 230 MHz

    A 50 Watt Conducted Immunity System (CIS) to Test According to IEC 61000-4-6. The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes ACS series power amplifier, Coupling Decoupling Network (CDN), directional couplers, attenuators, cables and CSAT software. These systems when properly configured are capable of testing your products to the all levels given in IEC 61000-4-6 up to 230 MHz. The two systems available and are given the table below. The IEC-61000-4-6 requires that an appropriate a coupling decoupling networks (CDN) with defined common mode impedance is used for testing conducted immunity. Com-Power has a wide variety of CDNs. The system can be customized include the CDNs to fit your application at the time of purchase. Before you begin testing with the CDN you will need to establish a calibrated drive levels corresponding to the test levels. When used with compatible signal generator and spectrum analyzer, the CSAT test software can fully automate this calibration and also perform the test. Com-Power CDNs are calibrated to meet the latest CISPR 16 test standards.

    This systyem includes:

    • · ACS-230-50 W Power Amplifier

    • · CDNs  (to be determined at the time of purchase)

    • · ATTN-6-100W

    • · ATTN-30-100W

    • · DCU-1000-100W

    • · Cable set

    • · Appropriate CDN shorting adapters

    • · ADA-515 150 Ohm to 50 Ohm adapters

    • · 50 Ohm terminator

    · COSAT/CSAT Software (optional) at additional cost.

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power CIS-50 Conducted Immunity System 50 Watts Data Sheet

     

    CIS-25 Conducted Immunity Test System -25 Watts 150 kHz to 230 MHz

    CIS-25 Conducted Immunity Test System -25 Watts 150 kHz to 230 MHz

    25 Watts Conducted Immunity System (CIS) to Test According to IEC 61000-4-6. The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes ACS series power amplifier, Coupling Decoupling Network (CDN), directional couplers, attenuators, cables and CSAT software. These systems when properly configured are capable of testing your products to the all levels given in IEC 61000-4-6 up to 230 MHz. The two systems available and are given the table below. The IEC-61000-4-6 requires that an appropriate a coupling decoupling networks (CDN) with defined common mode impedance is used for testing conducted immunity. Com-Power has a wide variety of CDNs. The system can be customized include the CDNs to fit your application at the time of purchase. Before you begin testing with the CDN you will need to establish a calibrated drive levels corresponding to the test levels. When used with compatible signal generator and spectrum analyzer, the CSAT test software can fully automate this calibration and also perform the test. Com-Power CDNs are calibrated to meet the latest CISPR 16 test standards.

     

    Test System Includes:

    • · ACS-230-25W Power Amplifier

    • · CDNs (to be determined at the time of purchase)

    • · ATTN-6-100W

    • · ATTN-30-100W

    • · DCU-1000-100W

    • · Cable set

    • · Appropriate CDN shorting adapters

    • · ADA-515 150 Ohm to 50 Ohm adapters

    • · 50 Ohm terminator

     

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power CIS-25 Conducted Immunity System 25 Watts Data Sheet