EnglishPortugueseSpanish

Request a Quote / Contact Us!

    Manufacturer

    Part Number or Numbers

    Com-Power Power Amplifiers

    Power Amplifiers by Com-Power Corporation

    • ACS-230-25W Broadband Power Amplifier for Conducted Susceptibilty 150 kHz to 230 MHz
    • ACS-230-50W Power Amplifier for Conducted Immunity 150 kHz to 230 MHz
    • ACS-250-100W Broadband Power Amplifier for Conducted Immunity 150 kHz to 250 MHz
    • AFM-1500 Power Amplifiers for FM transmitters: 1500 W, 2000 W, 3000 W, etc 87.5 MHz to 108 MHz
    • ARI-1000-200W 200 Watt Power Amplifier 80 MHz to 1 GHz
    • ARI-300K 300 Watt Power Amplifier: DC – 300 KHz for Mil-Std-461
    • ARI-6000-100W Power Amplifier for Radiated Susceptibility to 700 MHz to 6 GHz

    ACS-230-25W Broadband Power Amplifier: For Conducted Susceptibilty 150 kHz to 230 MHz
    ACS-230-25W

    The ACS-230-25W is part of Com-Power’s series of broadband RF amplifiers; diverse in application, yet specifically geared for use in EMC immunity testing applications. The ACS-230-25W model was engineered to provide high gain, with excellent efficiency and reliability, at an unbeatable price. It is the perfect amplifier solution for IEC 61000-4-6 Conducted Immunity testing (150 kHz to 230 MHz), complementing Com-Power’s full line of Coupling/Decoupling Networks (CDN’s) and related test and calibration accessories. With its 43 dB gain, 25 Watt nominal power output, it easily achieves 3 Vrms or 10 Vrms test levels with any compliant coupling network (CDN, EM Clamp, Injection Probe, etc.) The ACS-230-25W amplifier complies with all required technical specifications for IEC 61000-4-6 compliance testing, yet its low cost makes it affordable even as part of a pre-compliance testing solution.

    Specifications:
    General:

    · Frequency Range: 150 kHz to 230 MHz
    • · Rated Power Output: 25 watts into 2:1 VSWR
    • · Gain : 43 dB ±2 dB
    • · Input for rated output : 0 dBm (typical)
    • · Automatic Safety Shut-off: 30 watts ± 2
    • · Power Output @ 1 dB Compression Point: N/A
    Input:
    • · Impedance : 50 ohms (nominal)
    • · VSWR : 1.7 (maximum)
    • · Input Signal Modulation Compatibility:: AM, FM, or Pulse modulation
    • · Connector: Type N on Front Panel 
    Output:
    • · Impedance    : 50 ohms (nominal)
    • · VSWR  : 1.7 (maximum)
    • · Harmonic distortion : -20 dBc at 25 watts
    • · Mismatch Tolerance: Automatic Safety Shut-off @ VSWR >7
    • · Connector   : Type N on Front Panel
    Power:
    • · AC, Single Phase: 100-240 VAC 50/60 Hz
    Display and Interfaces:
    • · Front Panel Display (Column 1): Amplifier Current measurement Data
    • · Front Panel Display (Column 2): Amplifier Temperature measurement data
    • · Front Panel Display (Column 3): Load VSWR, RF Power Input/Output, Gain
    • · Remote Interlock (optional) : 2-pin DIN
    Mechanical:
    • · Cooling : Forced air (self-contained fans)
    • · Size: 19” Rack 2U
    • · Weight : 25 lbs (11.3 kg)
    • · Operating Temperature Range: 0° C to +40° C

     

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power ACS-230-25W Broadband Power Amplifier Data Sheet

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power ACS-230-25W Broadband Power Amplifier Manual

    • ACS-230-50W Power Amplifier for Conducted Immunity 150 kHz to 230 MHz
    ACS-230
    ACS-230-50W is part of Com-Power’s series of broadband RF amplifiers; diverse in application, yet specifically geared for use in EMC immunity testing applications. It was engineered to provide high gain, with excellent efficiency and reliability, at an unbeatable price. It has 47 dB gain, 50 Watt nominal power output., The ACS-230-50W amplifier complies with all required technical specifications for IEC 61000-4-6 compliance testing, yet its low cost makes it affordable even as part of a pre-compliance testing solution.

    • Specifications:

      General:

      · Frequency Range: 150 kHz to 230 MHz

    • · Rated Power Output: 50 watts into 2:1 VSWR
    • · Gain: 47 dB ±2 dB
    • · Input for rated output: 0 dBm (typical)
    • · Automatic Safety Shut-off: 50 watts ± 2
    • · Power Output @ 1 dB Compression Point: N/A

    Input:
    • · Impedance 50 ohms (nominal)
    • · VSWR: 1.7 (maximum)
    • · Input Signal Modulation Compatibility: AM, FM, or Pulse modulation
    • · Connector: Type N on Front Panel

    Output:
    • · Impedance: 50 ohms (nominal)
    • · VSWR: 1.7 (maximum)
    • · Harmonic distortion: -17 dBc at 50 watts
    • · Mismatch Tolerance: Automatic Safety Shut-off @ VSWR >7
    • · Connector: Type N on Front Panel

    Power: (Universal)
    • · AC, Single Phase: 100-240 VAC 50/60 Hz
    • · Display and Interfaces: USB Remote Interface
    • · Front Panel Display (Column 1): Amplifier Current measurement Data
    • · Front Panel Display (Column 2): Amplifier Temperature measurement data
    • · Front Panel Display (Column 3): Load VSWR, RF Power Input/Output, Gain
    • · Remote Interlock (optional): 2-pin DIN

    Mechanical:
    • · Cooling: Forced air (self-contained fans)
    • · Size: 19” Rack 4U
    • · Weight: 50 lbs (22.6 kg)
    • · Operating Temperature Range: 0° C to +40° C

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power ACS-230-50W Broadband Power Amplifier Data Sheet

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power ACS-230-50W Broadband Power Amplifier Manual

    • ACS-250-100W Broadband Power Amplifier for Conducted Immunity 150 kHz to 250 MHz
    ACS-250-100W

    The ACS-250-100W is part of Com-Power’s series of broadband RF amplifiers; diverse in application, yet specifically geared for use in EMC immunity testing applications. The ACS-250-100W model was engineered to provide high gain, with excellent efficiency and reliability, at an unbeatable price. It has 50 dB gain, 100 Watt nominal power output. The ACS-250-100W amplifier complies with all required technical specifications for IEC 61000-4-6 compliance testing, yet its low cost makes it affordable even as part of a pre-compliance testing solution

    • Specifications:

      General:

      · Frequency Range: 150 kHz to 250 MHz

    • · Rated Power Output: 100 watts into 2:1 VSWR
    • · Gain: 50 dB ±2 dB
    • · Input for rated output: 0 dBm (typical)
    • · Automatic Safety Shut-off: 140 watt
    • · Power Output @ 1 dB Compression Point: No Compression unit 100 W
    Input:
    • · Impedance 50 ohms (nominal)
    • · VSWR: 1.7 (maximum
    • · Input Signal Modulation Compatibility: AM, FM, or Pulse modulation
    • · Connector: Type N on Front Panel

    Output:
    • · Impedance: 50 ohms (nominal)
    • · VSWR: 1.7 (maximum)
    • · Harmonic distortion: 15 dBc at 50 watts
    • · Mismatch Tolerance: Automatic Safety Shut-off @ VSWR >7
    • · Connector: Type N on Front Panel

    Power: (Universal)
    • · AC, Single Phase: 100-240 VAC 50/60 Hz
    • · Display and Interfaces: USB Remote Interface
    • · Front Panel Display (Column 1): Amplifier Current measurement Data
    • · Front Panel Display (Column 2): Amplifier Temperature measurement data
    • · Front Panel Display (Column 3): Load VSWR, RF Power Input/Output, Gain
    • · Remote Interlock (optional): 2-pin DIN

    Mechanical:
    • · Cooling: Forced air (self-contained fans)
    • · Size: 19” Rack 4U
    • · Weight: 47 lbs (21.4 kg)
    • · Operating Temperature Range: 0° C to +40° C

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power ACS-250-100W Broadband Power Amplifier Data Sheet

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power ACS-250-100W Broadband Power Amplifier Manual

    • AFM-1500 Power Amplifiers for FM transmitters: 1500 W, 2000 W, 3000 W, etc 87.5 MHz to 108 MHz

    AFM-1500

      • Specifications:
        General:
    · Frequency Range: 87.5 kHz to 108 MHz
    • · Rated Power Output: 1500 watts
    • · Input for rated output: 2.5 Watts (max)
    • · RF Checkpoint at output: 0.707 Vrms (+10 dBm max.)

    Input:
    • · Impedance 50 ohms (nominal)
    • · VSWR: 1.2:1 (maximum)
    • · Input Signal Modulation Compatibility: FM
    • · Connector: Type BNC on Rear Panel

    Output:
    • ·Impedance: 50 ohms (nominal)
    • · VSWR: 1.2:1 (maximum)
    • · Harmonic distortion: 65 dBc (min) at 1500 watts
    • · Mismatch Tolerance: Automatic Safety Shut-off @ VSWR >1.8
    • · Connector: Type 7/16” on front panel

    Power:
    • · Power Amplifier Supply: 27 VDC, 100 A (external)
    • · Controller Supply: +/- 12 VDC, 1 A (external)
    • · Power Consumption: 2200 Watts (max)
    • · Efficiency: 68% (min)
    • · Display and Interfaces: USB Remote Interface
    • · Front Panel Display (Column 1): Individual Modules current measurement data
    • · Front Panel Display (Column 2): Individual Modules temperature measurement data
    • · Front Panel Display (Column 3): Load VSWR, RF Power Input/Output, Gain

    Mechanical:
    • · Cooling: Forced air (self-contained fans)
    • · Size: 19” Rack 3U
    • · Weight: 75 lbs (34 kg)
    • · Operating Temperature Range: 0° C to 30° C

    • ARI-1000-200W 200 Watt Power Amplifier 80 MHz to 1 GHz
    ARI-1000-200W
    The Com-Power ARI-1000-200W is a 200 Watt broadband Power Amplifier operating over the frequency range of 80 MHz to 1 GHz. This amplifier utilizes Class A linear power devices that provide an excellent 3rd order intercept point, high gain, and wide dynamic range. Due to robust engineering and employment of the most advanced devices and components, this amplifier achieves high efficiency operation with proven reliability. The ARI-1000-200W may be operated locally via the front panel controls and also by remote control access via its Ethernet, RS232 or IEEE-488 (GPIB) communications ports.

    ARI-1000-200W

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power ARI-1000-200W Broadband Power Amplifier Data Sheet

    • ARI-300K 300 Watt Power Amplifier: DC – 300 KHz for Mil-Std-461
    ARI-300K
    The Com-Power ARI-300K Power Amplifier is specifically geared for conducted and radiated susceptibility testing such as that described in MIL-STD-461 (CS101 & RS101) and RTCA DO-160 (Section 18), in addition to other standards.
    The ARI-300K operates from DC to 300 kHz. Its output power capabilities exceed 300 Watts into 1 ohm or 2 ohm loads; 150 Watts into 4 ohms; and 75 Watts into 8 ohms (refer to graphs below for minimum output specifications).
    The amplifier is equipped with protection circuitry to avoid damage in the case of input overload, improper output connections (shorted or improper loads), over-temperature as well as over-current conditions.
    The digital front panel display indicates the internal temperature of the amplifier as well as the bias current. There are also LED indicators for over-temperature and over-current fault conditions.

    Specifications:

    GENERAL

    • · Products Description: Power Amplifier
    • · Application: Conducted/Radiated Susceptibility Testing
    • · Standards: MIL-STD-461, RTCA DO-160, etc.
    • · Frequency Range: DC to 300 kHz
    • · Output Power: (see ‘ARI-300K Min. Power Output Specifications’ graph)
    • · Input Impedance: 10 kΩ (nominal)
    • · Output Impedance: 6.25 mΩ (nominal)
    • · Output Voltage: (see ‘ARI-300K Min. Voltage Output Specifications’ graph)
    • · Distortion: ≤0.3%
    • · DC Drift: < ±1.5 mV (after 30 minutes of operation)
    • · Phase Response: < ±1.5 mV (after 30 minutes of operation)

    ELECTRICAL
    • · AC Input Power: 100-250 Volts AC (50/60 Hz) 1000 VA (maximum)

    INPUT/OUTPUT CONNECTORS
    • · Input Connector: BNC (female)
    • · Output Connectors: (2) x 4 mm Banana Jack Binding Posts
    • · AC Input Connector: IEC C13 Receptable

    ENVIRONMENTAL
    • · Operating Temperature: 40° F to 104° F (5° C to 40° C)
    • · Cooling: Forced Air

    MECHANICAL
    • · Dimensions(HxWxD): 6.125” x 19” x 23.25” (15.9 cm x 48.3 cm x 59 cm)
    • · Rack Mount Dimensions (top/bottom feet removed, not including front handles): (3U) 5.25” x 19” x 22.25” (13.34 cm x 48.3 cm x 56.5 cm)

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_SheetCom-Power ARI-300-K Broadband Power Amplifier Data Sheet

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power ARI-300-K Broadband Power Amplifier Manual

    • ARI-6000-100W Power Amplifier for Radiated Susceptibility to 700 MHz to 6 GHz

    ARI-6000-100W

    The ARI-6000-100W is part of Com-Power’s series of broadband RF amplifiers; diverse in application, yet specifically geared for use in EMC immunity testing applications. The ARI-6000-100W model was engineered to provide high gain, with excellent efficiency and reliability, at an unbeatable price. It has 53 dB gain minimum, 100 Watt typical power output.

    • · Frequency Range: 0.7 – 6.0 GHz
    • · Saturated Output Power: 100 Watts Typical
    • · P1dB Output Power:60 Watts Minimum
    • · Small Signal Gain: +53 dB Minimum
    • · Power Flatness (Pin 0 dBm): ±4.0 dB Maximum
    • · IP3: +54 dBm Typical
    • · Input VSWR: 2:1 max
    • · Harmonics: -20 dBc typical @ P1dB
    • · Spurious Signals < -60 dBc typical @ P1dB
    • · Input/Output Impedance: 50 Ohms Nominal
    • · AC Input Power: 3,000 Watts Maximum
    • · AC Input: 100 – 240 VAC, single phase
    • · RF Input: 0 dBm nominal +3 dBm max without damage
    • · RF Input Signal Format: CW/AM/FM/PM/Pulse
    • · Class of Operation: A
    • · Dimensions: 19” x 8.75” x 24”
    • · Weight: 95 Lbs.
    • · Connectors: Type-N
    • · Grounding: Chassis
    • · Cooling: Internal Forced Air
    • · Operating Temperature: 0° C to +50° C
    • · Operating Humidity: 95% Non-condensing
    • · Operating Altitude: Up to 10,000’ Above Sea Level
    • · Shock and Vibration: Normal Truck Transport

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_SheetCom-Power ARI-6000-100W Broadband Power Amplifier Data Sheet

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Com-Power ARI-6000-100W Broadband Power Amplifier Manual