EnglishPortugueseSpanish
Schlöder Product List

Schlöder- ESD Simulators
• SESD 216 ESD Simulator 16,5 KV
• SESD 230 ESD Simulator 30 kV
• SESD 30000 EDS Simulator 30 kV
• SEDS 2910 ESD – Test System 30 KV
Schlöder- EMC Generators / Measurement System
• CDG 7000 Conducted Disturbances Test System
• CWG 1500 Surge / Hybrid Generators
• CWG 2500 Surge / Combination Wave Generators
• MGA 1033 Magnetic Field Generator And Analizer
• CAL 1250 Magnetic Field Calibrator
• PG 01-2000 Pulse Generator
• PGA 1240 Immunity DC – 300 kHz
• PGA 1240-5A & PGA 1240-16A Power DC Generators
• PGA – 1330 Immunity Generator
Schlöder- Burst Generators
• SFT 1400 Burst Generator 125 KHZ
• SFT 1420 Burst Generator 2 MHZ
• SFT 2400 EFT/Burst Generator 2 MHZ
• SFT 2420 EFT/Burst Generator 2 MHZ
• VIS 1700 Voltage Interruption Simulator
Schlöder- CDN – Coupling Decoupling Networks
Schlöder- Coupling Networks For Burst & Surge
-CN 1240-32 And CN 1240-125 Coupling Switchable Networks
-Mains Operation 3-Phase
• CWG 520
• CWG 523 / CWG 523-550
• CWG 524 CWG 524-550
• CWG 524-B / CWG 524-B-550
Interconnection Lines / Surge test only
• CWG 1525
• CWG 1526
• CWG 1528
Schlöder Current Monitoring Probes
• CDG CMP-45 Current Monitoring Probe
• CDG CMP-46 Current Monitoring Probe
• CDG A CMP-46 Calibration Set for the CDG CMP-46 Current Monitoring Probe
Schlöder- Accessories
-Burst Generator Accessories
• CWG 520 – 3-phase coupling network, 4 x 16 A – Burst and Surge
• CWG 523, CWG 523-550, CWG 524 CWG 524–550 – 3-phase Coupling Network, 4 x 32 / 60 A – Burst and Surge
• CWG 524-B – 3-phase Coupling Network, 4 x 60 A – Burst only
• EMV-SOFT – Remote control software for SFT, CWG, VIS
• SFT 415 – Capacitive Coupling Clamp (CCC)
• SFT 415-1 – Capacitive Coupling Clamp with protection cover
• SFT 415-CS – Calibration Set for verification the CCC
• SFT 430 HV Cable for Burst Generator
• SFT 450-Set – Attenuator Set
• SFT 470 – Probe set for Burst generator to create short time magnetic fields
ESD Simulator Accessories
• SESD 271 – Vertical Coupling Plate
• SESD 272 – Earth Cable
• SESD 30 S 120 – ESD Remote Control Software
• SESD 30 T 1000 – Support Arm with Balancer
• SESD 3020 – SESD 3027 – Test Tip´s for ESD
• SESD 3036 – Hook for Balancer
• SESD 8800-4 – ESD Target 4GHz
Surge / Hybrid Generator Accessories
• CWG 520, CWG 520 / 550 – 3-Phase Coupling network
• CWG 523, CWG 523-550, CWG 524, CWG 524-550- Coupling networks for Burst and Surge testing
• CWG 550 – External 18 µF capacitor in a housing
• CWG 553 – External 0,5 µF capacitor + 40 Ohm resistor in housing
• CWG 554 – External 9 µF + 10 Ohm resistor in housing
• CWG 1525 – CDN for 2 unshielded, balanced signal lines, 1 A, with gas discharger arrester
• CWG 1526-4, CWG 1526-10 – CDN for 2 unshielded, unbalanced data – and signal lines, 4 A or 10 A
• CWG 1528 – CDN for 4 unshielded, unbalanced data – and signal lines, 6 A, with RS 232 interface
• EMV-SOFT – Control software for SFT, CWG and VIS generators
Immunity, 10 kHz – 230 MHz Accessories
• CDN xxx -Coupling/Decoupling
• CDG A 31xx – Calibration adapters for CDN’s
• CDN-EMCL-20 & CDN EMCL-35 – EM Clamps
• CDN ABCL-20 – Decoupling Clamp
• CDN EMCL-NW_10 – Matching Network
• BCI-P1 – Clamp Bulk Current Injection (BCI) with Calibration Set
• CDG CMP-45 – Current Monitoring Probe With Calibration Set
• CDG CMP-46 – Current Monitoring Probe
• CDG A CMP-46 – Calibration Set
• CDG 6050 – 6dB Attenuator, 20W
• CDG 6050-100W – 6dB Attenuator, 100
Immunity, DC – 150 KHZ Accessories
• CN xxx - Coupling Networks
• CN 1240 xx - Coupling networks, switchable
Magnetic Field Generator Accessories
• CMGA_HCST - Helmholtz Coils
• MGA_LS/RL - Loop Sensor
• MGA_Bx - Test adapter, EN 55103
Voltage Interruption Simulator Accessories
• VIS 740 Step Transformer
• EMV-SOFT - Control software for SFT, CWG and VIS generators
Schlöder- Helmholtz Coils
Schlöder- Signal Generator SG 0282
Schlöder- Isolation – Transformers With Double Shield Winding
Schlöder Power Frequency Magnetic Field Immunity Tests
• Schlöder MGA_BC-500 Field Coil acc. to EN 55103-2
• Schlöder MGA 1030 Magnetic Field System Data Sheet
• Schlöder MGA 1030 Magnetic Field Generator and Analyzer Additional Equipment Data Sheet
Products By Standars

Company Overview
Data Sheets
Product List

Request a Quote / Contact Us!

    Manufacturer

    Part Number or Numbers

    CN 1240-32 CN 1240-125 Coupling Networks

    Schlöder CN 1240-32 and CN 1240-125 Coupling switchable network M2 – M5 (AC/DC) acc. IEC/EN 61000-4-16

     

    Schlöder CN 1240-32 and CN 1240-125 Coupling Networks

    • Switchable coupling network M2, M3, M4, M5, AC/DC acc. IEC/EN 61000-4-16
    • For continuous disturbances and short-term disturbances up to ± 300 V
    • Remote control in connection with PGA 1240 or MGA 1030
    • Can also be operated as a stand-alone device

     

    Description
    According to IEC / EN 61000-4-16, at the frequency of the electrical power supply (either DC, 16,67Hz, 50Hz or 60Hz) the test stimuli is applied as both continuous and short-duration disturbances. Otherwise, over the frequency range 15Hz to 150kHz, the test stimuli is applied as continuous disturbances.The normal duration for short duration disturbances at the electricity supply frequency is1 second.

    The CN 1240 is a multifunctional coupling network for test levels up to ± 300 VDC or 300 VAC in connection with test generators PGA 1240 or MGA 1030. In this case the CN 1240 is remote controlled via the application software of the test generators.

    Otherwise the coupling network may be front panel operated as a stand-alone device.

    The CN 1240 operates as a M2, M3, M4 or M5 coupling network – selection by a rotary switch.

    The coupling capacitor is shorted out for the DC tests by a push-button.For automated tests you may toggle between AC and DC via the USB-port

     

    Aaronia_AG_EMC_Analyzer_Bundle-1_Data_Sheet Schlöder CN 1240-32 & CN 1240-125 Coupling Networks Data Sheet