EnglishPortugueseSpanish
Schlöder Product List

Schlöder- ESD Simulators
• SESD 216 ESD Simulator 16,5 KV
• SESD 230 ESD Simulator 30 kV
• SESD 30000 EDS Simulator 30 kV
• SEDS 2910 ESD – Test System 30 KV
Schlöder- EMC Generators / Measurement System
• CDG 7000 Conducted Disturbances Test System
• CWG 1500 Surge / Hybrid Generators
• CWG 2500 Surge / Combination Wave Generators
• MGA 1033 Magnetic Field Generator And Analizer
• CAL 1250 Magnetic Field Calibrator
• PG 01-2000 Pulse Generator
• PGA 1240 Immunity DC – 300 kHz
• PGA 1240-5A & PGA 1240-16A Power DC Generators
• PGA – 1330 Immunity Generator
Schlöder- Burst Generators
• SFT 1400 Burst Generator 125 KHZ
• SFT 1420 Burst Generator 2 MHZ
• SFT 2400 EFT/Burst Generator 2 MHZ
• SFT 2420 EFT/Burst Generator 2 MHZ
• VIS 1700 Voltage Interruption Simulator
Schlöder- CDN – Coupling Decoupling Networks
Schlöder- Coupling Networks For Burst & Surge
-CN 1240-32 And CN 1240-125 Coupling Switchable Networks
-Mains Operation 3-Phase
• CWG 520
• CWG 523 / CWG 523-550
• CWG 524 CWG 524-550
• CWG 524-B / CWG 524-B-550
Interconnection Lines / Surge test only
• CWG 1525
• CWG 1526
• CWG 1528
Schlöder Current Monitoring Probes
• CDG CMP-45 Current Monitoring Probe
• CDG CMP-46 Current Monitoring Probe
• CDG A CMP-46 Calibration Set for the CDG CMP-46 Current Monitoring Probe
Schlöder- Accessories
-Burst Generator Accessories
• CWG 520 – 3-phase coupling network, 4 x 16 A – Burst and Surge
• CWG 523, CWG 523-550, CWG 524 CWG 524–550 – 3-phase Coupling Network, 4 x 32 / 60 A – Burst and Surge
• CWG 524-B – 3-phase Coupling Network, 4 x 60 A – Burst only
• EMV-SOFT – Remote control software for SFT, CWG, VIS
• SFT 415 – Capacitive Coupling Clamp (CCC)
• SFT 415-1 – Capacitive Coupling Clamp with protection cover
• SFT 415-CS – Calibration Set for verification the CCC
• SFT 430 HV Cable for Burst Generator
• SFT 450-Set – Attenuator Set
• SFT 470 – Probe set for Burst generator to create short time magnetic fields
ESD Simulator Accessories
• SESD 271 – Vertical Coupling Plate
• SESD 272 – Earth Cable
• SESD 30 S 120 – ESD Remote Control Software
• SESD 30 T 1000 – Support Arm with Balancer
• SESD 3020 – SESD 3027 – Test Tip´s for ESD
• SESD 3036 – Hook for Balancer
• SESD 8800-4 – ESD Target 4GHz
Surge / Hybrid Generator Accessories
• CWG 520, CWG 520 / 550 – 3-Phase Coupling network
• CWG 523, CWG 523-550, CWG 524, CWG 524-550- Coupling networks for Burst and Surge testing
• CWG 550 – External 18 µF capacitor in a housing
• CWG 553 – External 0,5 µF capacitor + 40 Ohm resistor in housing
• CWG 554 – External 9 µF + 10 Ohm resistor in housing
• CWG 1525 – CDN for 2 unshielded, balanced signal lines, 1 A, with gas discharger arrester
• CWG 1526-4, CWG 1526-10 – CDN for 2 unshielded, unbalanced data – and signal lines, 4 A or 10 A
• CWG 1528 – CDN for 4 unshielded, unbalanced data – and signal lines, 6 A, with RS 232 interface
• EMV-SOFT – Control software for SFT, CWG and VIS generators
Immunity, 10 kHz – 230 MHz Accessories
• CDN xxx -Coupling/Decoupling
• CDG A 31xx – Calibration adapters for CDN’s
• CDN-EMCL-20 & CDN EMCL-35 – EM Clamps
• CDN ABCL-20 – Decoupling Clamp
• CDN EMCL-NW_10 – Matching Network
• BCI-P1 – Clamp Bulk Current Injection (BCI) with Calibration Set
• CDG CMP-45 – Current Monitoring Probe With Calibration Set
• CDG CMP-46 – Current Monitoring Probe
• CDG A CMP-46 – Calibration Set
• CDG 6050 – 6dB Attenuator, 20W
• CDG 6050-100W – 6dB Attenuator, 100
Immunity, DC – 150 KHZ Accessories
• CN xxx - Coupling Networks
• CN 1240 xx - Coupling networks, switchable
Magnetic Field Generator Accessories
• CMGA_HCST - Helmholtz Coils
• MGA_LS/RL - Loop Sensor
• MGA_Bx - Test adapter, EN 55103
Voltage Interruption Simulator Accessories
• VIS 740 Step Transformer
• EMV-SOFT - Control software for SFT, CWG and VIS generators
Schlöder- Helmholtz Coils
Schlöder- Signal Generator SG 0282
Schlöder- Isolation – Transformers With Double Shield Winding
Schlöder Power Frequency Magnetic Field Immunity Tests
• Schlöder MGA_BC-500 Field Coil acc. to EN 55103-2
• Schlöder MGA 1030 Magnetic Field System Data Sheet
• Schlöder MGA 1030 Magnetic Field Generator and Analyzer Additional Equipment Data Sheet
Products By Standars

Company Overview
Data Sheets
Product List

Request a Quote / Contact Us!

    Manufacturer

    Part Number or Numbers

    SCHLÖEDER Product List

    Model #
    Product Description
    IEC / EN 61000 – 4 – 2 ESD
     
    SESD 216
    ESD generator 10 kV CON / 16,5 kV AIR acc. to IEC 61000-4-2, 150 pF / 330 ohm 
    SESD 230
    ESD generator 30 kV CON / 30 kV AIR acc. to IEC 61000-4-2, 150 pF / 330 ohm 
    SESD 30000
    ESD generator 30 kV CON / 30 kV AIR acc. to IEC 61000-4-2 and ISO 10605/2008, 150 pF/ 330 ohm, mechanical polarity module, includes factory calibration for 150 pF/330 ohm 
    SESD 30000 P
    ESD generator 30 kV CON / 30 kV AIR acc. to IEC 61000-4-2 and ISO 10605/2008, 150 pF/ 330 ohm, electronic polarity module, includes factory calibration for 150 pF/330 ohm 
    SESD 30000 A
    ESD generator 30 kV CON / 30 kV AIR acc. to IEC 61000-4-2 and ISO 10605/2008, 150 pF/ 330 ohm, electronic polarity module, includes factory calibration for 150 pF/330 ohm, battery and main operation, includes factory calibration for 150 pF/330 ohm 
    SESD 30 S 100
    Control software ESD, with optical interface and fiber optic cable 10m. For the generators SESD 216, SESD 230, SESD 30000 
    KAL SESD 30000-4
    ISO 10605 calibration (4 impedances – 202 values), before delivery of a new ESD generator, if a customer purchase the SESD 30000 /SESD 30000P /SESD 3000A with the modules 330 pF and 2000 ohm for automotive application. 
    SESD 30 C 50
    Capacity module 50 pF 
    SESD 30 C 100
    Capacity module 100 pF 
    SESD 30 C 150
    Capacity module 150 pF 
    SESD 30 C 200
    Capacity module 200 pF 
    SESD 30 C 250
    Capacity module 250 pF 
    SESD 30 C 300
    Capacity module 300 pF 
    SESD 30 C 330
    Capacity module 330 pF 
    SESD 30 C 500
    Capacity module 500 pF 
    SESD 30 C 680
    Capacity module 680 pF 
    SESD 30 C 1000
    Capacity module 1000 pF 
    SESD 30 R 0
    Resistor module 0 ohm,only for AIR discharge,C max 330 pF 
    SESD 30 R 50
    Resistor module 50 ohm 
    SESD 30 R 100
    Resistor module 100 ohm 
    SESD 30 R 150
    Resistor module 150 ohm 
    SESD 30 R 200
    Resistor module 200 ohm 
    SESD 30 R 250
    Resistor module 250 ohm 
    SESD 30 R 330
    Resistor module 330 ohm 
    SESD 30 R 500
    Resistor module 500 ohm 
    SESD 30 R 560
    Resistor module 560 ohm 
    SESD 30 R 1000
    Resistor module 1000 ohm 
    SESD 30 R 1500
    Resistor module 1500 ohm 
    SESD 30 R 2000
    Resistor module 2000 ohm 
    SESD 30 R 5000
    Resistor module 5000 ohm 
    SESD 30 P 200
    Electronic polarity module 
    SESD 30 M 200
    Fast discharge module, rise time < 400 ps 
    SESD 30 T 630
    Balancer for ESD 
    SESD 3036
    Hook on the generator – for hanging on a balancer. Before delivery of a new ESD generator, if a customer purchase a new ESD generator 
    SESD 3036
    Hook on the generator – for hanging on a balancer. Mounting a hook for an existing customer SESD xxx generator 
    SESD 30 Z 01
    BNC trigger output, instead of a trigger input 
    SESD 30 Z 02
    Special module with HV cable 1m long (instead of test tip) 
    SESD 3021
    Test tip (metal part) Contact discharge, 30 kV, standard 
    SESD 3025
    Test tip (metal part) Air discharge, 30 mm half ball 
    SESD 3026
    Test tip (metal part) “CON” with spring contact, 50 mm long 
    SESD 3027
    Test tip (metal part) “CON” with spring contact, 70 mm long 
    SESD 30 MOD-1
    HBM (Human Body Model) module 5 ns (100 pF/1500 ohm), 100 pF module and 330 ohm module are needed – the 1500Ω are obtained by the HBM module + 330 ohm. Included plot. 
    SESD 30 MOD-1-U2
    Modification of an existing SESD 30000 for option HBM (MOD-1) 
    SESD 30 MOD-3-U1
    Modification of an existing SESD 30000 for automatic absorbing. Calibration has to be quoted additionally. 
    SESD 231
    Discharge return cable, 2m long 
    SESD 271
    VCP – vertical coupling plate, include earth cable SESD 272 
    SESD 272
    Earth cable include 2 x 470 kohm resistor, 2 m long 
    SESD 8800- 4
    ESD calibration set 2 ohm (4 GHz), traceable to National standard. Necessary acc. to the new revision of the standard IEC 61000-4-2. Included accredited calibration. 
    ATT-20
    Additional attenuator 20 dB for the SESD 8800-4 
    SESD 2910
    ESD test system, 30 kV for testing electro explosive devices acc. EN 13763-13- Basic unit, includes electronic polarity module, RS 232 interface. 
    SESD 29 R 05
    Resistor module 0,5 ohm 
    SESD 29 R 2
    Resistor module 2 ohm 
    SESD 29 R 5
    Resistor module 5 ohm 
    SESD 29 R 10
    Resistor module 10 ohm 
    SESD 29 R 20
    Resistor module 20 ohm 
    SESD 29 R 150
    Resistor module 150 ohm 
    SESD 29 R 330
    Resistor module 330 ohm 
    SESD 29 R 500
    Resistor module 500 ohm 
    SESD 29 R 2000
    Resistor module 2000 ohm 
    SESD 29 R 5000
    Resistor module 5000 ohm 
    SESD 29 C 150
    Capacity modules 150 pF 
    SESD 29 C 200
    Capacity modules 200 pF 
    SESD 29 C 300
    Capacity modules 300 pF 
    SESD 29 C 330
    Capacity modules 330 pF 
    SESD 29 C 470
    Capacity modules 470 pF 
    SESD 29 C 500
    Capacity modules 500 pF 
    SESD 29 C 1000
    Capacity modules 1000 pF 
    SESD 29 C 1500
    Capacity modules 1500 pF 
    SESD 29 C 2000
    Capacity modules 2000 pF 
    SESD 29 C 2500
    Capacity modules 2500 pF 
    SESD 29 C 3000
    Capacity modules 3000 pF 
    SESD 29 C 3500
    Capacity modules 3500 pF 
    SESD 29 C 5000
    Capacity modules 5000 pF 
    SESD 2990
    Transport case for max. 12 modules 
    IEC / EN 61000 – 4 – 4 Burst
     
    SFT 1400
    Burst generator 125 kHz, 5 kV, acc. to IEC 61000-4-4 
    SFT 1420
    Burst generator 2 MHz, 4.8 kV acc. to IEC 61000-4-4 
    SFT 415
    Capacity clamp to test I/O leads, in conformity with IEC 61000-4-4, includes the high-voltage cable. 
    SFT 415-1
    Capacity clamp to test I/O leads, in conformity with IEC 61000-4-4 with special protection against touch, includes the high voltage cable. 
    SFT 415-CS
    Calibration Set for calibration of the capacity coupling clamp acc. IEC 61000-4-4, 2012 
    SFT 450-1
    50 Ohm Attenuator for calibration SFT 415; 54 dB, conform divider 500:1 at 50 ohm termination (scope input) 
    SFT 450-2
    1000 Ohm Attenuator for calibration SFT 415 and SFT 1400, 1420; 60 dB, conform divider 1000:1 at 50 ohm termination (scope input) 
    SFT 450-Set
    50 Ohm and 1000 Ohm Attenuator for calibration the SFT 415 and SFT 1400, SFT 1420 
    SFT 470
    Probe set for Burst generator, to create short time magnetic fields 
    IEC / EN 61000 – 4 – 5 Surge
     
    CWG 1500
    Surge generator according to IEC 61000-4-5, max. 4,4 kV 
    CWG 520
    3-phase coupling network, 400 V / 4 x 16 A for burst and surge 
    CWG 520 – 550
    3-phase coupling network, max. 550 V / 4 x 16 A for burst and surge 
    CWG 523
    3-phase coupling network, 400 V / 4 x 32 A for burst and surge 
    CWG 523- 550
    3-phase coupling network, max. 550 V / 4 x 32 A for burst and surge 
    CWG 524
    3-phase coupling network, 400 V / 4 x 60 A for burst and surge 
    CWG 524 – 550
    3-phase coupling network, max. 550 V / 4 x 60 A for burst and surge 
    CWG 524-B
    3-phase coupling network, 400 V / 4 x 60 A, for burst coupling only 
    CWG 1525
    Coupling network, 2 unshielded symmetrical data lines (field bus, interconnectin lines), 1 A, max. 50V AC/DC, coupling via gas arrestors 
    CWG 1526-4
    Coupling network, 0,5uF / 40 Ohm, 2 unshielded unsymmetrical interconnection lines, 4A/ 240 VAC, 120 VDC 
    CWG 1526-10
    Coupling network, , 2 unshielded unsymmetrical interconnection lines, 10A/ 240 VAC, 120 VDC 
    CWG 1528
    Coupling network, 0,5uF / 40 Ohm, 4 unshielded unsymmetrical interconnection lines, 6 A, 3 x 250 VAC, max. 120 VDC; Remote control RS 232 
    CWG 550
    External 18 μF capacitor within a housing, acc. IEC 61000-4-5 Ed.3.0, 2014; max. 250 VAC, max. 400 VDC, max. pulse voltage 4,4 kV, include HV cable 35 cm, for verification of the Surge pulse / tests to cable shields. 
    CWG 553
    0,5 μF capacitor + 40 Ohm resistor within a housing, acc. IEC 61000-4-5 Ed.3.0, 2014; max. 250 VAC, max. 400 VDC, max. pulse voltage 4,4 kV, include HV cable 90 cm, for verification of the Surge pulse / tests to cable shields. 
    CWG 554
    External 18 μF and 9 μF capacitor and 10 ohm within a housing, acc. IEC 61000-4-5 Ed.3.0, 2014, max. 550 VAC, 1200 VDC, max. pulse voltage 6,0 kV, for Surge tests without coupling networks to cable shields and verification of the Surge pulse. Includes HV cable, to connect to the CWG 1500 
    CDG 6000-DC
    Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 kHz – 300 MHz, amplifier 25W for 10 V (15 V) with 80% AM (without 6 dB), – built-in directional coupler 
    CDG 6000
    Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 kHz – 300 MHz, amplifier 25W for 10 V (15 V) with 80% AM (without 6 dB), – without directional coupler 
    CDG 6000-75-DC
    Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 kHz – 300 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 dB), – built-in directional coupler 
    CDG 6000-75
    Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 kHz – 300 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 dB), – without directional coupler 
    CDG 6000-75-DC_10
    Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 10 kHz – 250 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 dB), – built-in directional coupler 
    CDG 6000-75_10
    Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 10 kHz – 250 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 dB), – without directional coupler 
    CDG 6050
    6 dB Attenuator, 20W, for test level max. 20V 
    CDG 6050-100W
    6 dB Attenuator, 100W 
    Coupling networks – Calibration adapters required Special CDNs upon requirement
     
    CDN L1-16
    1 line, 250VAC, 16A, 150 kHz – 230 MHz, 4mm MC jack, black 
    CDN M1
    ground cable PE, 250 VAC, 150 kHz–230 MHz, 4mm jack, gn/yellow 
    CDN M1_10
    ground cable PE, 250 VAC, 10 kHz – 230 MHz, 4mm jack, gn/yellow 
    CDN M2-16
    2 lines L + N, 250 VAC, 16 A, 150 kHz – 300 MHz 
    CDN M2-16_10
    2 lines L + N, 250 VAC, 16 A, 10 kHz – 230 MHz 
    CDN M2-32
    2 lines L + N, 250 VAC, 32 A, 150 kHz – 230 MHz 
    CDN M2-32 HV
    2 lines L + N, 600 VAC, 32 A, 150 kHz – 230 MHz 
    CDN M2-63 HV
    2 lines L + N, 600 VAC, 63 A, 150 kHz – 80 MHz 
    CDN M2-100 HV
    2 lines L + N, 600 VAC, 100 A, 150 kHz – 80 MHz 
    CDN M2+M3-16
    2 + 3 lines, switchable, 250 VAC, 16 A, 150 kHz – 300 MHz 
    CDN M2+M3-16_10
    2 + 3 lines, switchable, 250 VAC, 16 A, 10 kHz – 230 MHz 
    CDN M2+M3-32
    2 + 3 lines, switchable, 250 VAC, 32 A, 150 kHz – 230 MHz 
    CDN M3-16
    3 lines L + N + PE, 250 VAC, 16 A, 150 kHz – 300 MHz 
    CDN M3-L16
    3 lines 3 x L, 250 VAC, 16 A, 150 kHz – 230 MHz 
    CDN M3-32
    3 lines L + N + PE, 250 VAC, 32 A, 150 kHz – 230 MHz 
    CDN M3-L32
    3 lines 3 x L, 250 VAC, 32 A, 150 kHz – 230 MHz 
    CDN M3-L32_10
    3 lines 3 x L, 250 VAC, 32 A, 10 kHz – 230 MHz 
    CDN M3-LN32
    3 lines L1 + L2 + N, 250 VAC, 32 A, 150 kHz – 230 MHz 
    CDN M3-32 HV
    3 lines L + N + PE, 600 VAC, 32 A, 150 kHz – 80 MHz 
    CDN M3-63 HV
    3 lines L + N + PE, 600 VAC, 63 A, 150 kHz – 80 MHz 
    CDN M3-100 HV
    3 lines L + N + PE, 600 VAC, 100 A, 150 kHz – 80 MHz 
    CDN M3-L100 HV
    3 lines, 3 x L 600 VAC, 100 A, 150 kHz – 80 MHz 
    CDN M4-16
    4 lines 3 x L, 1 x PE, 250 VAC, 16 A, 150 kHz – 230 MHz 
    CDN M4-N16
    4 lines 3 x L, 1 x N, 250 VAC, 16 A, 150 kHz – 230 MHz 
    CDN M4-32
    4 lines 3 x L, 1 x PE, 250 VAC, 32 A, 150 kHz – 230 MHz 
    CDN M4-N32
    4 lines 3 x L, 1 x N, 250 VAC, 32 A, 150 kHz – 230 MHz 
    CDN M4-32 HV
    4 lines 3 x L, 1 x PE, 600 VAC, 32 A, 150 kHz – 80 MHz 
    CDN M4-32_10
    4 lines 3 x L, 1 x PE, 250 VAC, 32 A, 10 kHz – 230 MHz 
    CDN M4-N63 HV
    4 lines 3 x L, 1 x N, 600 VAC, 63 A, 150 kHz – 80 MHz 
    CDN M4-63 HV
    4 lines 3 x L, 1 x PE, 600 VAC, 63 A, 150 kHz – 80 MHz 
    CDN M4-100 HV
    4 lines 3 x L, 1 x PE, 600 VAC, 100 A, 150 kHz – 80 MHz, incl. cable 3m with 2 plugs. 
    CDN M4-N100 HV
    4 lines 3 x L, 1 x N, 600 VAC, 100 A, 150 kHz – 80 MHz, incl. cable 3m with 2 plugs. 
    CDN M5-16
    5 lines 3 x L, 1 x N, 1 x PE, 250 VAC, 16 A, 150 kHz – 230 MHz 
    CDN M5-32
    5 lines 3 x L, 1 x N, 1 x PE, 250 VAC, 32 A, 150 kHz – 230 MHz 
    CDN M5-32 HV
    5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 32 A, 150 kHz – 80 MHz 
    CDN M5-32 VHV
    5 lines 3 x L, 1 x N, 1 x PE, 1000 VAC, 32 A, 150 kHz – 80 MHz 
    CDN M5-63 HV
    5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 63 A, 150 kHz – 80 MHz 
    CDN M5-100 HV
    5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 100 A, 150 kHz – 80 MHz 
    CDN S 1-75
    1 screened line, 75 Ohm connector BNC, 150 kHz – 230 MHz 
    CDN S 1
    1 screened line, connector BNC, 150 kHz – 230 MHz 
    CDN S 1_10
    1 screened line, connector BNC, 10 kHz – 230 MHz 
    CDN S 2
    2 screened lines, connector XLR, 150 kHz – 230 MHz 
    CDN S 2_10
    2 screened lines, connector XLR, 10 kHz – 230 MHz 
    CDN S 3_10
    3 screened lines, connector XLR, 10 kHz – 230 MHz 
    CDN S 4
    screened lines, connector XLR, 5 pole, 150 kHz – 230 MHz 
    CDN S 8
    screened lines, connector 8 pole Mini DIN, 150 kHz – 230 MHz 
    CDN S 9
    screened lines, connector 9-pol SUB-D, 150 kHz – 230 MHz 
    CDN S 9_10
    screened lines, connector 9-pol SUB-D, 10 kHz – 230 MHz 
    CDN S 15
    screened lines, connector 15-pol SUB-D, 150 kHz – 230 MHz 
    CDN S 25
    screened lines, connector 25-pol SUB-D, 150 kHz – 230 MHz 
    CDN S K75-BNC
    Screened lines, for coaxial-cable 75 Ohm, BNC 150 kHz – 230 MHz 
    CDN AF 2
    2 unscreened non balanced lines, terminal clamp, 150kHz – 300MHz 
    CDN AF 2-MC
    2 unscreened non balanced lines, 4mm MC jacks,150kHz – 300MHz 
    CDN AF 2-MC_10
    2 unscreened non balanced lines, 4mm MC jacks, 10kHz – 230MHz 
    CDN AF 3
    3 unscreened non balanced lines, terminal clamp, 150kHz – 230MHz 
    CDN AF 3-MC
    3 unscreened non balanced lines, 4mm MC jacks,150kHz – 230MHz 
    CDN AF 3-MC_10
    3 unscreened non balanced lines, 4mm MC jacks, 10kHz – 230MHz 
    CDN AF 4
    4 unscreened non balanced lines, terminal clamp, 150kHz – 230MHz 
    CDN AF 4_10
    4 unscreened non balanced lines, terminal clamp, 10 kHz – 230MHz 
    CDN AF 4-MC
    4 unscreened non balanced lines, 4mm MC jacks, 150kHz – 230MHz 
    CDN AF 4-MC_10
    4 unscreened non balanced lines, 4mm MC jacks, 10kHz – 230MHz 
    CDN AF 5-MC
    5 unscreened non balanced lines, 4mm MC jacks, 150kHz – 230MHz 
    CDN AF 5-MC_10
    5 unscreened non balanced lines, 4mm MC jacks, 10kHz – 230MHz 
    CDN AF 8
    8 unscreened non balanced lines, terminal clamp, 150kHz – 230MHz 
    CDN AF 8_10
    8 unscreened non balanced lines, terminal clamp, 10kHz – 80MHz 
    CDN AF 8-MC
    8 unscreened non balanced lines, 4mm MC jacks, 150kHz – 80MHz 
    CDN AF 8-MC_10
    8 unscreened non balanced lines, 4mm MC jacks, 10kHz – 80MHz 
    CDN AF 8-SUBD_10
    8 unscreened non balanced lines, 4mm SUB-D9, 10kHz – 230MHz 
    CDN AF 12 SUB-D
    12 unscreened non balanced lines, SUB-D15, 150kHz – 230MHz 
    CDN T 2
    2 unscreened balanced lines, terminal clamp, 150 kHz – 230 MHz 
    CDN T 2_10
    2 unscreened balanced lines, terminal clamp, 10 kHz – 80 MHz 
    CDN T 4
    4 unscreened balanced lines, terminal clamp, 150 kHz – 230 MHz 
    CDN T 4_10
    4 unscreened balanced lines, terminal clamp, 10 kHz – 80 MHz 
    CDN T 8
    8 unscreened balanced lines, terminal clamp, 150 kHz – 230 MHz 
    CDN RJ 11
    unscreened lines, 6 pins, RJ11 connector, 150 kHz – 230 MHz 
    CDN RJ 45
    unscreened lines, 8 pins, RJ45 connector, 150 kHz – 230 MHz 
    CDN RJ 45S
    screened lines, 8 pins, screened RJ45 connector, 150 kHz-230 MHz 
    CDN RJ 45S_10
    screened lines, 8 pins, screened RJ45 connector, 10 kHz-230 MHz 
    CDN HDMI
    screened lines, 19 pins, screened HDMI connector, 150kHz-230MHz, HDMI 1.3a 
    CDN Firewire
    CDN for IEEE 1394 units, 6 pol, Firewire jack, 150 kHz – 230 MHz 
    CDN CAN-BUS L4
    CDN for CAN-BUS, 9 pol SUB-D socket, 150 kHz – 230 MHz 
    CDN CAN-BUS L5
    CDN for CAN-BUS, 9 pol SUB-D socket, 150 kHz – 230 MHz 
    CDN USB-C
    CDN for central USB units, 8 pins connector, 150 kHz – 230 MHz, EUT side: USB-B -> square, AE side: USB-A -> flat 
    CDN USB-C_10
    CDN for central USB units, 8 pins connector, 10 kHz-230 MHz, EUT side: USB-B -> square, AE side: USB-A -> flat 
    CDN USB-P
    CDN for periphery USB units, 8 pins connector, 150 kHz-230 MHz, EUT side: USB-A -> flat, AE side: USB-B -> square 
    CDN USB-P_10
    CDN for periphery USB units, 8 pins connector, 10 kHz-230 MHz, EUT side: USB-A -> flat, AE side: USB-B -> square 
    CDN USB-3.0
    CDN for USB 3.0, 150 kHz-230 MHz, EUT side: USB-A -> flat, AE side: USB-A -> flat 
    CDN D 100
    100 ohm resistor for direct injection, connectors: BNC / alligator clip 
    CDNs for Emissions Testing
     
    CDN M2-16_9K EMI
    2 lines L + N, for emissions testing, 250 VAC, 16A, 9 kHz – 300 MHz 
    CDN M3-16_9K EMI
    3 lines L+N+PE, for emissions testing, 250 VAC, 16A, 9 kHz–300MHz 
    Calibration material
     
    CDG A 3100
    Mounting plate include 50/150 ohm passage and 50 ohm termination 
    CDG 3110
    100 Ohm resistor (50/150 ohm passage) BNC to BNC 
    CDG A 3101
    Calibration adaptor for CDN M3, M2, M1, L1 – 16A / 32A 
    CDG A 3107
    Calibration adaptor for CDN M5/M4-16/32A / AF5/AF4-MC (AE-port) 
    CDG A 3128
    Calibration adaptor for CDN M5/M4-16/32A / AF5/AF4-MC (EUTport) 
    CDG A 3125
    Calibration adaptor for CDN M3, M2, 63A 
    CDG A 3126
    Calibration adaptor for CDN M3, M2, 100A 
    CDG A 3115
    Calibration adaptor for CDN M5, M4, 63A 
    CDG A 3116
    Calibration adaptor for CDN M5, M4, 100A 
    CDG A 3102
    Calibration adaptor for CDN AF 2 
    CDG A 3101
    Calibration adaptor for CDN AF 2-MC 
    CDG A 3108
    Calibration adaptor for CDN AF 3 
    CDG A 3101
    Calibration adaptor for CDN AF 3-MC 
    CDG A 3108
    Calibration adaptor for CDN AF 4 
    CDG A 3107
    Calibration adaptor for CDN AF 5/AF4-MC (AE-port) 
    CDG A 3128
    Calibration adaptor for CDN AF 5/AF4-MC (EUT port) 
    CDG A 3110
    Calibration adaptor for CDN AF 8 
    CDG A 3114
    Calibration adaptor for CDN AF 8-MC 
    CDG A 3143
    Calibration adaptor for CDN AF 12-SUBD 
    CDG A 3103
    Calibration adaptor for CDN S 1 
    CDG A 3104
    Calibration adaptor for CDN S 2 
    CDG A 3130
    Calibration adaptor for CDN S 4 
    CDG A 3129
    Calibration adaptor for CDN S 8 
    CDG A 3105
    Calibration adaptor for CDN S 9 
    CDG A 3113
    Calibration adaptor for CDN S 15 
    CDG A 3106
    Calibration adaptor for CDN S 25 
    CDG A 3144
    Calibration adaptor for CDN S K75-BNC 
    CDG A 3111
    Calibration adaptor for CDN T2 
    CDG A 3112
    Calibration adaptor for CDN T4 
    CDG A 3109
    Calibration adaptor for CDN T8 
    CDG A 3117
    Calibration adaptor for CDN RJ 45 S 
    CDG A 3118
    Calibration adaptor for CDN RJ 45 
    CDG A 3120
    Calibration adaptor for CDN RJ 11 
    CDG A 3121
    Calibration adaptor for CDN USB-C (also USB 3.0C) 
    CDG A 3122
    Calibration adaptor for CDN USB-P (also USB 3.0P) 
    CDG A 3123
    Calibration adaptor for CDN HDMI 
    CDG A 3127
    Calibration adaptor for CDN Firewire 
    CDG A 3131
    Calibration adaptor for CDN CAN-BUS, 9-pol SUB-D male and CDN AF 8-SUBD_10 
    Coupling clamps
     
    CDN DCL-20
    Decoupling clamp for immunity, acc. IEC 61000-4-6, 100 kHz – 1000 MHz, cable diameter max. 20mm. 
    CDN EMCL-20
    EM clamp acc. to /EC/EN 61000-4-6 incl. calibration kit and factory calibration, traceable, cable diameter max. 20 mm 
    CDN EMCL-35
    EM clamp acc. to /EC/EN 61000-4-6 incl. calibration kit and factory calibration, traceable, cable diameter max. 35 mm 
    CDN-EMCL-NW_10
    Matching network 10 kHz – 150 kHz, for using EMCL 20 from 10 kHz to 150 kHz 
    KAL SET EMCL
    Calibration set for EMCL, acc. IEC 61000-4-6, Ed. 4.0, 2014 
    IEC / EN 61000 – 4 – 8 / EN 55103 / MIL STD / ISO DC – 250 kHz
     
    MGA 1033
    Magnetic field analyzer and generator acc. to EN 55103 + IEC 6100-4-8 + MIL-STD-461 E/F, DC-250 kHz, Amplifier 50V / 16A 
    MGA 1034_16-SYS
    Complete Test-System for Magnetic field tests acc. ISO 11452-8, MIL-STD-461 E/F and other – incl. compensation board and Triax Coil MGA_HCST_50-28 for magnetic fields until 1000 A/m at 1000 Hz, DC – 250 kHz, Amplifier 50V / 16A 
    MGA_RLS 133
    Radiating / Loop sensor 133 mm acc. to EN 55103-2, incl. 3m cable 
    MGA_RL 120
    Radiating loop 120 mm acc. to MIL-STD-461E / RS101, 3m cable 
    MGA_BC-500
    Radiating loop 50 cm, acc. to EN 55103-2, item A 3.1 
    MGA_LS 040
    Loop sensor 40 mm acc. to MIL-STD-461E / RE101, incl. 3m cable 
    MGA_LS 133
    Loop sensor 133 mm acc. to MIL-STD-461E / RE101, 3m cable 
    MGA_B1
    Test adapter acc. to EN 55103-2, Fig. B1 
    MGA_B2
    Calibration network acc. to EN 55103-2, Fig. B2 
    MGA_B4
    Current transducer acc. to EN 55103-2, Fig. B4 
    MGA_HCS_100-60
    Helmholtz coil 1-axis (50 kHz) 1,00×1,00m, distance 0,60m 
    MGA_HCS_125-75
    Helmholtz coil 1-axis (50 kHz) 1,25×1,25m, distance 0,75m 
    MGA_HCST_50-28
    Helmholtz coil 3-axis (50 kHz) 0,5 x 0,5m, distance 0,28m 
    MGA_HCS_50-28
    Helmholtz coil 1-axis (50 kHz) 0,5 x 0,5m, distance 0,28m 
    MGA_CT-50A
    Coupling transformer acc. MIL-STD-461 CS 101 
    MGA_ISS-19
    Coupling transformer for tests acc. DO160, Sec. 19 (19.3.1; 19.3.2; 19.3.3), in combination with MGA 1033 
    MGA_SO_CE101
    Software plug-in MIL-STD-461E / CE101 
    MGA_SO_CS101
    Software plug-in MIL-STD-461E / CS101 
    MGA_SO_CS109
    Software plug-in MIL-STD-461E / CS109 
    MGA_SO_4-16
    Software plug-in EN 61000-4-16 
    IEC / EN 61000 – 4 – 16 Immunity DC – 150 kHz
     
    PGA 1240-5
    Power Generator DC – 300 kHz; +/-50V; +/-5A, also for the continuous disturbances acc. IEC 61000-4-16.
    PGA 1240-16
    Power Generator DC – 300 kHz; +/-50V; +/-16 A
    PGA 1240-PSG 300
    Option “External voltage-source”, input for phase-triggering of an external voltage-source, 50 ohm output, for the short-term tests up to 300V. Option instead of PGA 1330.
    PGA 1330
    Immunity generator for short-term tests up to 300 V, with 50 ohm serial resistor to the output
    IT – 06
    Isolation transformer 6 A
    IT – 16
    Isolation transformer 16 A
    CN M2-AC-32
    Coupling network for 2 lines 250 VAC, 15 Hz – 150 kHz
    CN M2-DC-32
    Coupling network for 2 lines 250 VDC
    CN M3-AC-32
    Coupling network for 3 lines 250 VAC, 15 Hz – 150 kHz
    CN M3-DC-32
    Coupling network for 3 lines 250 VDC
    CN M4-AC-32
    Coupling network for 4 lines 250 VAC, 15 Hz – 150 kHz
    CN M5-AC-32
    Coupling network for 5 lines 250 VAC, 15 Hz – 150 kHz
    CN 1240-32
    Coupling network switchable M2, M3, M4, M5, 32A, 250 V AC+DC, 15 Hz – 150 kHz
    CN 1240-125
    Coupling network switchable M2, M3, M4, M5, 125A, 250 V AC+DC, 15 Hz – 150 kHz
    CN M2+M3-32-HV
    CN for 2 and 3 lines, 32A, 520 VAC / 620 VDC, Housing 4 HE
    CN AF 2
    CN for 2 unsymmetrical, unshielded lines, DC, 15 Hz – 150 kHz 
    CN AF 4
    CN for 4 unsymmetrical, unshielded lines, DC, 15 Hz – 150 kHz 
    CN AF 4 
    CN for 4 unsymmetrical, unshielded lines, DC, 15 Hz – 150 kHz with 4mm MC banana plugs 
    CN AF 8
    CN for 8 unsymmetrical, unshielded lines, DC, 15 Hz – 150 kHz
    CN T 2
    CN for 2 symmetrical, shielded data lines, DC, 15 Hz – 150 kHz
    CN T 4
    CN for 4 symmetrical, shielded data lines, DC, 15 Hz – 150 kHz
    CN T 8
    CN for 8 symmetrical, shielded data lines, DC, 15 Hz – 150 kHz
    CN RJ 45
    CN for unsymmetrical, unshielded RJ45, DC, 15 Hz – 150 kHz
    CN ITU-T
    CN acc. ITU – Fig.1/K 54, for Telecom lines
    IEC / EN 61000 – 4 – 11 and – 4 – 29 Voltage interruption and Voltage dips
     
    VIS 1700_1
    Voltage interruption simulator according to IEC 61000-4-11, AC and DC ramp function, includes factory calibration VIS 1700_1 
    VIS 740
    Step transformer 16,0 A for voltage dips, AC using only, 0%, 40%, 70%, 80% – necessary to reach the requirement acc. IEC 61000-4-11 (should also quote KAL VIS 740) 
    KAL VIS 740
    Additional cost for factory calibration of the step transformer. Before delivery of a new VIS 740, if a customer orders the VIS 1700_1 and VIS 740 
    RF – Power Amplifier
     
    PA 1020-25-250
    RF broadband power amplifier, 25 W, 100 kHz – 250 MHz 
    PA 1020-75-300
    RF broadband power amplifier, 75 W, 100 kHz – 300 MHz 
    PA 1020-75-400
    RF broadband power amplifier, 75 W, 100 kHz – 400 MHz 
    PA 1020-75-250
    RF broadband power amplifier, 75 W, 10 kHz – 250 MHz 
    PA 1020-180-400
    RF broadband power amplifier, 180 W, 1 MHz – 400 MHz 
    FNN Chapter 3.7.1 Rules (Electricity Meters)
     
    PG01-2000
    Pulse generator 0,1μs/2000μs, 10 kV acc. FNN rules 
    IEEE 644
     
    CAL 1250
    Generator of magnetic fields with 3 channel generator / amplifier for calibration 50 / 60 Hz. 
    Additions
     
    EMV-SOFT