Schlöder Product List
Schlöder- ESD Simulators
• SESD 216 ESD Simulator 16,5 KV
• SESD 230 ESD Simulator 30 kV
• SESD 30000 EDS Simulator 30 kV
• SEDS 2910 ESD – Test System 30 KV
Schlöder- EMC Generators / Measurement System
• CDG 7000 Conducted Disturbances Test System
• CWG 1500 Surge / Hybrid Generators
• CWG 2500 Surge / Combination Wave Generators
• MGA 1033 Magnetic Field Generator And Analizer
• CAL 1250 Magnetic Field Calibrator
• PG 01-2000 Pulse Generator
• PGA 1240 Immunity DC – 300 kHz
• PGA 1240-5A & PGA 1240-16A Power DC Generators
• PGA – 1330 Immunity Generator
Schlöder- Burst Generators
• SFT 1400 Burst Generator 125 KHZ
• SFT 1420 Burst Generator 2 MHZ
• SFT 2400 EFT/Burst Generator 2 MHZ
• SFT 2420 EFT/Burst Generator 2 MHZ
• VIS 1700 Voltage Interruption Simulator
Schlöder- CDN – Coupling Decoupling Networks
Schlöder- Coupling Networks For Burst & Surge
-CN 1240-32 And CN 1240-125 Coupling Switchable Networks
-Mains Operation 3-Phase
• CWG 520
• CWG 523 / CWG 523-550
• CWG 524 CWG 524-550
• CWG 524-B / CWG 524-B-550
Interconnection Lines / Surge test only
• CWG 1525
• CWG 1526
• CWG 1528
Schlöder Current Monitoring Probes
• CDG CMP-45 Current Monitoring Probe
• CDG CMP-46 Current Monitoring Probe
• CDG A CMP-46 Calibration Set for the CDG CMP-46 Current Monitoring Probe
Schlöder- Accessories
-Burst Generator Accessories
• CWG 520 – 3-phase coupling network, 4 x 16 A – Burst and Surge
• CWG 523, CWG 523-550, CWG 524 CWG 524–550 – 3-phase Coupling Network, 4 x 32 / 60 A – Burst and Surge
• CWG 524-B – 3-phase Coupling Network, 4 x 60 A – Burst only
• EMV-SOFT – Remote control software for SFT, CWG, VIS
• SFT 415 – Capacitive Coupling Clamp (CCC)
• SFT 415-1 – Capacitive Coupling Clamp with protection cover
• SFT 415-CS – Calibration Set for verification the CCC
• SFT 430 HV Cable for Burst Generator
• SFT 450-Set – Attenuator Set
• SFT 470 – Probe set for Burst generator to create short time magnetic fields
ESD Simulator Accessories
• SESD 271 – Vertical Coupling Plate
• SESD 272 – Earth Cable
• SESD 30 S 120 – ESD Remote Control Software
• SESD 30 T 1000 – Support Arm with Balancer
• SESD 3020 – SESD 3027 – Test Tip´s for ESD
• SESD 3036 – Hook for Balancer
• SESD 8800-4 – ESD Target 4GHz
Surge / Hybrid Generator Accessories
• CWG 520, CWG 520 / 550 – 3-Phase Coupling network
• CWG 523, CWG 523-550, CWG 524, CWG 524-550- Coupling networks for Burst and Surge testing
• CWG 550 – External 18 µF capacitor in a housing
• CWG 553 – External 0,5 µF capacitor + 40 Ohm resistor in housing
• CWG 554 – External 9 µF + 10 Ohm resistor in housing
• CWG 1525 – CDN for 2 unshielded, balanced signal lines, 1 A, with gas discharger arrester
• CWG 1526-4, CWG 1526-10 – CDN for 2 unshielded, unbalanced data – and signal lines, 4 A or 10 A
• CWG 1528 – CDN for 4 unshielded, unbalanced data – and signal lines, 6 A, with RS 232 interface
• EMV-SOFT – Control software for SFT, CWG and VIS generators
Immunity, 10 kHz – 230 MHz Accessories
• CDN xxx -Coupling/Decoupling
• CDG A 31xx – Calibration adapters for CDN’s
• CDN-EMCL-20 & CDN EMCL-35 – EM Clamps
• CDN ABCL-20 – Decoupling Clamp
• CDN EMCL-NW_10 – Matching Network
• BCI-P1 – Clamp Bulk Current Injection (BCI) with Calibration Set
• CDG CMP-45 – Current Monitoring Probe With Calibration Set
• CDG CMP-46 – Current Monitoring Probe
• CDG A CMP-46 – Calibration Set
• CDG 6050 – 6dB Attenuator, 20W
• CDG 6050-100W – 6dB Attenuator, 100
Immunity, DC – 150 KHZ Accessories
• CN xxx - Coupling Networks
• CN 1240 xx - Coupling networks, switchable
Magnetic Field Generator Accessories
• CMGA_HCST - Helmholtz Coils
• MGA_LS/RL - Loop Sensor
• MGA_Bx - Test adapter, EN 55103
Voltage Interruption Simulator Accessories
• VIS 740 Step Transformer
• EMV-SOFT - Control software for SFT, CWG and VIS generators
Schlöder- Helmholtz Coils
Schlöder- Signal Generator SG 0282
Schlöder- Isolation – Transformers With Double Shield Winding
Schlöder Power Frequency Magnetic Field Immunity Tests
• Schlöder MGA_BC-500 Field Coil acc. to EN 55103-2
• Schlöder MGA 1030 Magnetic Field System Data Sheet
• Schlöder MGA 1030 Magnetic Field Generator and Analyzer Additional Equipment Data Sheet
Products By Standars
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
SCHLÖEDER Product List
Model # |
Product Description |
IEC / EN 61000 – 4 – 2 ESD |
|
SESD 216 |
ESD generator 10 kV CON / 16,5 kV AIR acc. to IEC 61000-4-2, 150 pF / 330 ohm |
SESD 230 |
ESD generator 30 kV CON / 30 kV AIR acc. to IEC 61000-4-2, 150 pF / 330 ohm |
SESD 30000 |
ESD generator 30 kV CON / 30 kV AIR acc. to IEC 61000-4-2 and ISO 10605/2008, 150 pF/ 330 ohm, mechanical polarity module, includes factory calibration for 150 pF/330 ohm |
SESD 30000 P |
ESD generator 30 kV CON / 30 kV AIR acc. to IEC 61000-4-2 and ISO 10605/2008, 150 pF/ 330 ohm, electronic polarity module, includes factory calibration for 150 pF/330 ohm |
SESD 30000 A |
ESD generator 30 kV CON / 30 kV AIR acc. to IEC 61000-4-2 and ISO 10605/2008, 150 pF/ 330 ohm, electronic polarity module, includes factory calibration for 150 pF/330 ohm, battery and main operation, includes factory calibration for 150 pF/330 ohm |
SESD 30 S 100 |
Control software ESD, with optical interface and fiber optic cable 10m. For the generators SESD 216, SESD 230, SESD 30000 |
KAL SESD 30000-4 |
ISO 10605 calibration (4 impedances – 202 values), before delivery of a new ESD generator, if a customer purchase the SESD 30000 /SESD 30000P /SESD 3000A with the modules 330 pF and 2000 ohm for automotive application. |
SESD 30 C 50 |
Capacity module 50 pF |
SESD 30 C 100 |
Capacity module 100 pF |
SESD 30 C 150 |
Capacity module 150 pF |
SESD 30 C 200 |
Capacity module 200 pF |
SESD 30 C 250 |
Capacity module 250 pF |
SESD 30 C 300 |
Capacity module 300 pF |
SESD 30 C 330 |
Capacity module 330 pF |
SESD 30 C 500 |
Capacity module 500 pF |
SESD 30 C 680 |
Capacity module 680 pF |
SESD 30 C 1000 |
Capacity module 1000 pF |
SESD 30 R 0 |
Resistor module 0 ohm,only for AIR discharge,C max 330 pF |
SESD 30 R 50 |
Resistor module 50 ohm |
SESD 30 R 100 |
Resistor module 100 ohm |
SESD 30 R 150 |
Resistor module 150 ohm |
SESD 30 R 200 |
Resistor module 200 ohm |
SESD 30 R 250 |
Resistor module 250 ohm |
SESD 30 R 330 |
Resistor module 330 ohm |
SESD 30 R 500 |
Resistor module 500 ohm |
SESD 30 R 560 |
Resistor module 560 ohm |
SESD 30 R 1000 |
Resistor module 1000 ohm |
SESD 30 R 1500 |
Resistor module 1500 ohm |
SESD 30 R 2000 |
Resistor module 2000 ohm |
SESD 30 R 5000 |
Resistor module 5000 ohm |
SESD 30 P 200 |
Electronic polarity module |
SESD 30 M 200 |
Fast discharge module, rise time < 400 ps |
SESD 30 T 630 |
Balancer for ESD |
SESD 3036 |
Hook on the generator – for hanging on a balancer. Before delivery of a new ESD generator, if a customer purchase a new ESD generator |
SESD 3036 |
Hook on the generator – for hanging on a balancer. Mounting a hook for an existing customer SESD xxx generator |
SESD 30 Z 01 |
BNC trigger output, instead of a trigger input |
SESD 30 Z 02 |
Special module with HV cable 1m long (instead of test tip) |
SESD 3021 |
Test tip (metal part) Contact discharge, 30 kV, standard |
SESD 3025 |
Test tip (metal part) Air discharge, 30 mm half ball |
SESD 3026 |
Test tip (metal part) “CON” with spring contact, 50 mm long |
SESD 3027 |
Test tip (metal part) “CON” with spring contact, 70 mm long |
SESD 30 MOD-1 |
HBM (Human Body Model) module 5 ns (100 pF/1500 ohm), 100 pF module and 330 ohm module are needed – the 1500Ω are obtained by the HBM module + 330 ohm. Included plot. |
SESD 30 MOD-1-U2 |
Modification of an existing SESD 30000 for option HBM (MOD-1) |
SESD 30 MOD-3-U1 |
Modification of an existing SESD 30000 for automatic absorbing. Calibration has to be quoted additionally. |
SESD 231 |
Discharge return cable, 2m long |
SESD 271 |
VCP – vertical coupling plate, include earth cable SESD 272 |
SESD 272 |
Earth cable include 2 x 470 kohm resistor, 2 m long |
SESD 8800- 4 |
ESD calibration set 2 ohm (4 GHz), traceable to National standard. Necessary acc. to the new revision of the standard IEC 61000-4-2. Included accredited calibration. |
ATT-20 |
Additional attenuator 20 dB for the SESD 8800-4 |
SESD 2910 |
ESD test system, 30 kV for testing electro explosive devices acc. EN 13763-13- Basic unit, includes electronic polarity module, RS 232 interface. |
SESD 29 R 05 |
Resistor module 0,5 ohm |
SESD 29 R 2 |
Resistor module 2 ohm |
SESD 29 R 5 |
Resistor module 5 ohm |
SESD 29 R 10 |
Resistor module 10 ohm |
SESD 29 R 20 |
Resistor module 20 ohm |
SESD 29 R 150 |
Resistor module 150 ohm |
SESD 29 R 330 |
Resistor module 330 ohm |
SESD 29 R 500 |
Resistor module 500 ohm |
SESD 29 R 2000 |
Resistor module 2000 ohm |
SESD 29 R 5000 |
Resistor module 5000 ohm |
SESD 29 C 150 |
Capacity modules 150 pF |
SESD 29 C 200 |
Capacity modules 200 pF |
SESD 29 C 300 |
Capacity modules 300 pF |
SESD 29 C 330 |
Capacity modules 330 pF |
SESD 29 C 470 |
Capacity modules 470 pF |
SESD 29 C 500 |
Capacity modules 500 pF |
SESD 29 C 1000 |
Capacity modules 1000 pF |
SESD 29 C 1500 |
Capacity modules 1500 pF |
SESD 29 C 2000 |
Capacity modules 2000 pF |
SESD 29 C 2500 |
Capacity modules 2500 pF |
SESD 29 C 3000 |
Capacity modules 3000 pF |
SESD 29 C 3500 |
Capacity modules 3500 pF |
SESD 29 C 5000 |
Capacity modules 5000 pF |
SESD 2990 |
Transport case for max. 12 modules |
IEC / EN 61000 – 4 – 4 Burst |
|
SFT 1400 |
Burst generator 125 kHz, 5 kV, acc. to IEC 61000-4-4 |
SFT 1420 |
Burst generator 2 MHz, 4.8 kV acc. to IEC 61000-4-4 |
SFT 415 |
Capacity clamp to test I/O leads, in conformity with IEC 61000-4-4, includes the high-voltage cable. |
SFT 415-1 |
Capacity clamp to test I/O leads, in conformity with IEC 61000-4-4 with special protection against touch, includes the high voltage cable. |
SFT 415-CS |
Calibration Set for calibration of the capacity coupling clamp acc. IEC 61000-4-4, 2012 |
SFT 450-1 |
50 Ohm Attenuator for calibration SFT 415; 54 dB, conform divider 500:1 at 50 ohm termination (scope input) |
SFT 450-2 |
1000 Ohm Attenuator for calibration SFT 415 and SFT 1400, 1420; 60 dB, conform divider 1000:1 at 50 ohm termination (scope input) |
SFT 450-Set |
50 Ohm and 1000 Ohm Attenuator for calibration the SFT 415 and SFT 1400, SFT 1420 |
SFT 470 |
Probe set for Burst generator, to create short time magnetic fields |
IEC / EN 61000 – 4 – 5 Surge |
|
CWG 1500 |
Surge generator according to IEC 61000-4-5, max. 4,4 kV |
CWG 520 |
3-phase coupling network, 400 V / 4 x 16 A for burst and surge |
CWG 520 – 550 |
3-phase coupling network, max. 550 V / 4 x 16 A for burst and surge |
CWG 523 |
3-phase coupling network, 400 V / 4 x 32 A for burst and surge |
CWG 523- 550 |
3-phase coupling network, max. 550 V / 4 x 32 A for burst and surge |
CWG 524 |
3-phase coupling network, 400 V / 4 x 60 A for burst and surge |
CWG 524 – 550 |
3-phase coupling network, max. 550 V / 4 x 60 A for burst and surge |
CWG 524-B |
3-phase coupling network, 400 V / 4 x 60 A, for burst coupling only |
CWG 1525 |
Coupling network, 2 unshielded symmetrical data lines (field bus, interconnectin lines), 1 A, max. 50V AC/DC, coupling via gas arrestors |
CWG 1526-4 |
Coupling network, 0,5uF / 40 Ohm, 2 unshielded unsymmetrical interconnection lines, 4A/ 240 VAC, 120 VDC |
CWG 1526-10 |
Coupling network, , 2 unshielded unsymmetrical interconnection lines, 10A/ 240 VAC, 120 VDC |
CWG 1528 |
Coupling network, 0,5uF / 40 Ohm, 4 unshielded unsymmetrical interconnection lines, 6 A, 3 x 250 VAC, max. 120 VDC; Remote control RS 232 |
CWG 550 |
External 18 μF capacitor within a housing, acc. IEC 61000-4-5 Ed.3.0, 2014; max. 250 VAC, max. 400 VDC, max. pulse voltage 4,4 kV, include HV cable 35 cm, for verification of the Surge pulse / tests to cable shields. |
CWG 553 |
0,5 μF capacitor + 40 Ohm resistor within a housing, acc. IEC 61000-4-5 Ed.3.0, 2014; max. 250 VAC, max. 400 VDC, max. pulse voltage 4,4 kV, include HV cable 90 cm, for verification of the Surge pulse / tests to cable shields. |
CWG 554 |
External 18 μF and 9 μF capacitor and 10 ohm within a housing, acc. IEC 61000-4-5 Ed.3.0, 2014, max. 550 VAC, 1200 VDC, max. pulse voltage 6,0 kV, for Surge tests without coupling networks to cable shields and verification of the Surge pulse. Includes HV cable, to connect to the CWG 1500 |
CDG 6000-DC |
Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 kHz – 300 MHz, amplifier 25W for 10 V (15 V) with 80% AM (without 6 dB), – built-in directional coupler |
CDG 6000 |
Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 kHz – 300 MHz, amplifier 25W for 10 V (15 V) with 80% AM (without 6 dB), – without directional coupler |
CDG 6000-75-DC |
Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 kHz – 300 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 dB), – built-in directional coupler |
CDG 6000-75 |
Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 kHz – 300 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 dB), – without directional coupler |
CDG 6000-75-DC_10 |
Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 10 kHz – 250 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 dB), – built-in directional coupler |
CDG 6000-75_10 |
Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 10 kHz – 250 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 dB), – without directional coupler |
CDG 6050 |
6 dB Attenuator, 20W, for test level max. 20V |
CDG 6050-100W |
6 dB Attenuator, 100W |
Coupling networks – Calibration adapters required Special CDNs upon requirement |
|
CDN L1-16 |
1 line, 250VAC, 16A, 150 kHz – 230 MHz, 4mm MC jack, black |
CDN M1 |
ground cable PE, 250 VAC, 150 kHz–230 MHz, 4mm jack, gn/yellow |
CDN M1_10 |
ground cable PE, 250 VAC, 10 kHz – 230 MHz, 4mm jack, gn/yellow |
CDN M2-16 |
2 lines L + N, 250 VAC, 16 A, 150 kHz – 300 MHz |
CDN M2-16_10 |
2 lines L + N, 250 VAC, 16 A, 10 kHz – 230 MHz |
CDN M2-32 |
2 lines L + N, 250 VAC, 32 A, 150 kHz – 230 MHz |
CDN M2-32 HV |
2 lines L + N, 600 VAC, 32 A, 150 kHz – 230 MHz |
CDN M2-63 HV |
2 lines L + N, 600 VAC, 63 A, 150 kHz – 80 MHz |
CDN M2-100 HV |
2 lines L + N, 600 VAC, 100 A, 150 kHz – 80 MHz |
CDN M2+M3-16 |
2 + 3 lines, switchable, 250 VAC, 16 A, 150 kHz – 300 MHz |
CDN M2+M3-16_10 |
2 + 3 lines, switchable, 250 VAC, 16 A, 10 kHz – 230 MHz |
CDN M2+M3-32 |
2 + 3 lines, switchable, 250 VAC, 32 A, 150 kHz – 230 MHz |
CDN M3-16 |
3 lines L + N + PE, 250 VAC, 16 A, 150 kHz – 300 MHz |
CDN M3-L16 |
3 lines 3 x L, 250 VAC, 16 A, 150 kHz – 230 MHz |
CDN M3-32 |
3 lines L + N + PE, 250 VAC, 32 A, 150 kHz – 230 MHz |
CDN M3-L32 |
3 lines 3 x L, 250 VAC, 32 A, 150 kHz – 230 MHz |
CDN M3-L32_10 |
3 lines 3 x L, 250 VAC, 32 A, 10 kHz – 230 MHz |
CDN M3-LN32 |
3 lines L1 + L2 + N, 250 VAC, 32 A, 150 kHz – 230 MHz |
CDN M3-32 HV |
3 lines L + N + PE, 600 VAC, 32 A, 150 kHz – 80 MHz |
CDN M3-63 HV |
3 lines L + N + PE, 600 VAC, 63 A, 150 kHz – 80 MHz |
CDN M3-100 HV |
3 lines L + N + PE, 600 VAC, 100 A, 150 kHz – 80 MHz |
CDN M3-L100 HV |
3 lines, 3 x L 600 VAC, 100 A, 150 kHz – 80 MHz |
CDN M4-16 |
4 lines 3 x L, 1 x PE, 250 VAC, 16 A, 150 kHz – 230 MHz |
CDN M4-N16 |
4 lines 3 x L, 1 x N, 250 VAC, 16 A, 150 kHz – 230 MHz |
CDN M4-32 |
4 lines 3 x L, 1 x PE, 250 VAC, 32 A, 150 kHz – 230 MHz |
CDN M4-N32 |
4 lines 3 x L, 1 x N, 250 VAC, 32 A, 150 kHz – 230 MHz |
CDN M4-32 HV |
4 lines 3 x L, 1 x PE, 600 VAC, 32 A, 150 kHz – 80 MHz |
CDN M4-32_10 |
4 lines 3 x L, 1 x PE, 250 VAC, 32 A, 10 kHz – 230 MHz |
CDN M4-N63 HV |
4 lines 3 x L, 1 x N, 600 VAC, 63 A, 150 kHz – 80 MHz |
CDN M4-63 HV |
4 lines 3 x L, 1 x PE, 600 VAC, 63 A, 150 kHz – 80 MHz |
CDN M4-100 HV |
4 lines 3 x L, 1 x PE, 600 VAC, 100 A, 150 kHz – 80 MHz, incl. cable 3m with 2 plugs. |
CDN M4-N100 HV |
4 lines 3 x L, 1 x N, 600 VAC, 100 A, 150 kHz – 80 MHz, incl. cable 3m with 2 plugs. |
CDN M5-16 |
5 lines 3 x L, 1 x N, 1 x PE, 250 VAC, 16 A, 150 kHz – 230 MHz |
CDN M5-32 |
5 lines 3 x L, 1 x N, 1 x PE, 250 VAC, 32 A, 150 kHz – 230 MHz |
CDN M5-32 HV |
5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 32 A, 150 kHz – 80 MHz |
CDN M5-32 VHV |
5 lines 3 x L, 1 x N, 1 x PE, 1000 VAC, 32 A, 150 kHz – 80 MHz |
CDN M5-63 HV |
5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 63 A, 150 kHz – 80 MHz |
CDN M5-100 HV |
5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 100 A, 150 kHz – 80 MHz |
CDN S 1-75 |
1 screened line, 75 Ohm connector BNC, 150 kHz – 230 MHz |
CDN S 1 |
1 screened line, connector BNC, 150 kHz – 230 MHz |
CDN S 1_10 |
1 screened line, connector BNC, 10 kHz – 230 MHz |
CDN S 2 |
2 screened lines, connector XLR, 150 kHz – 230 MHz |
CDN S 2_10 |
2 screened lines, connector XLR, 10 kHz – 230 MHz |
CDN S 3_10 |
3 screened lines, connector XLR, 10 kHz – 230 MHz |
CDN S 4 |
screened lines, connector XLR, 5 pole, 150 kHz – 230 MHz |
CDN S 8 |
screened lines, connector 8 pole Mini DIN, 150 kHz – 230 MHz |
CDN S 9 |
screened lines, connector 9-pol SUB-D, 150 kHz – 230 MHz |
CDN S 9_10 |
screened lines, connector 9-pol SUB-D, 10 kHz – 230 MHz |
CDN S 15 |
screened lines, connector 15-pol SUB-D, 150 kHz – 230 MHz |
CDN S 25 |
screened lines, connector 25-pol SUB-D, 150 kHz – 230 MHz |
CDN S K75-BNC |
Screened lines, for coaxial-cable 75 Ohm, BNC 150 kHz – 230 MHz |
CDN AF 2 |
2 unscreened non balanced lines, terminal clamp, 150kHz – 300MHz |
CDN AF 2-MC |
2 unscreened non balanced lines, 4mm MC jacks,150kHz – 300MHz |
CDN AF 2-MC_10 |
2 unscreened non balanced lines, 4mm MC jacks, 10kHz – 230MHz |
CDN AF 3 |
3 unscreened non balanced lines, terminal clamp, 150kHz – 230MHz |
CDN AF 3-MC |
3 unscreened non balanced lines, 4mm MC jacks,150kHz – 230MHz |
CDN AF 3-MC_10 |
3 unscreened non balanced lines, 4mm MC jacks, 10kHz – 230MHz |
CDN AF 4 |
4 unscreened non balanced lines, terminal clamp, 150kHz – 230MHz |
CDN AF 4_10 |
4 unscreened non balanced lines, terminal clamp, 10 kHz – 230MHz |
CDN AF 4-MC |
4 unscreened non balanced lines, 4mm MC jacks, 150kHz – 230MHz |
CDN AF 4-MC_10 |
4 unscreened non balanced lines, 4mm MC jacks, 10kHz – 230MHz |
CDN AF 5-MC |
5 unscreened non balanced lines, 4mm MC jacks, 150kHz – 230MHz |
CDN AF 5-MC_10 |
5 unscreened non balanced lines, 4mm MC jacks, 10kHz – 230MHz |
CDN AF 8 |
8 unscreened non balanced lines, terminal clamp, 150kHz – 230MHz |
CDN AF 8_10 |
8 unscreened non balanced lines, terminal clamp, 10kHz – 80MHz |
CDN AF 8-MC |
8 unscreened non balanced lines, 4mm MC jacks, 150kHz – 80MHz |
CDN AF 8-MC_10 |
8 unscreened non balanced lines, 4mm MC jacks, 10kHz – 80MHz |
CDN AF 8-SUBD_10 |
8 unscreened non balanced lines, 4mm SUB-D9, 10kHz – 230MHz |
CDN AF 12 SUB-D |
12 unscreened non balanced lines, SUB-D15, 150kHz – 230MHz |
CDN T 2 |
2 unscreened balanced lines, terminal clamp, 150 kHz – 230 MHz |
CDN T 2_10 |
2 unscreened balanced lines, terminal clamp, 10 kHz – 80 MHz |
CDN T 4 |
4 unscreened balanced lines, terminal clamp, 150 kHz – 230 MHz |
CDN T 4_10 |
4 unscreened balanced lines, terminal clamp, 10 kHz – 80 MHz |
CDN T 8 |
8 unscreened balanced lines, terminal clamp, 150 kHz – 230 MHz |
CDN RJ 11 |
unscreened lines, 6 pins, RJ11 connector, 150 kHz – 230 MHz |
CDN RJ 45 |
unscreened lines, 8 pins, RJ45 connector, 150 kHz – 230 MHz |
CDN RJ 45S |
screened lines, 8 pins, screened RJ45 connector, 150 kHz-230 MHz |
CDN RJ 45S_10 |
screened lines, 8 pins, screened RJ45 connector, 10 kHz-230 MHz |
CDN HDMI |
screened lines, 19 pins, screened HDMI connector, 150kHz-230MHz, HDMI 1.3a |
CDN Firewire |
CDN for IEEE 1394 units, 6 pol, Firewire jack, 150 kHz – 230 MHz |
CDN CAN-BUS L4 |
CDN for CAN-BUS, 9 pol SUB-D socket, 150 kHz – 230 MHz |
CDN CAN-BUS L5 |
CDN for CAN-BUS, 9 pol SUB-D socket, 150 kHz – 230 MHz |
CDN USB-C |
CDN for central USB units, 8 pins connector, 150 kHz – 230 MHz, EUT side: USB-B -> square, AE side: USB-A -> flat |
CDN USB-C_10 |
CDN for central USB units, 8 pins connector, 10 kHz-230 MHz, EUT side: USB-B -> square, AE side: USB-A -> flat |
CDN USB-P |
CDN for periphery USB units, 8 pins connector, 150 kHz-230 MHz, EUT side: USB-A -> flat, AE side: USB-B -> square |
CDN USB-P_10 |
CDN for periphery USB units, 8 pins connector, 10 kHz-230 MHz, EUT side: USB-A -> flat, AE side: USB-B -> square |
CDN USB-3.0 |
CDN for USB 3.0, 150 kHz-230 MHz, EUT side: USB-A -> flat, AE side: USB-A -> flat |
CDN D 100 |
100 ohm resistor for direct injection, connectors: BNC / alligator clip |
CDNs for Emissions Testing |
|
CDN M2-16_9K EMI |
2 lines L + N, for emissions testing, 250 VAC, 16A, 9 kHz – 300 MHz |
CDN M3-16_9K EMI |
3 lines L+N+PE, for emissions testing, 250 VAC, 16A, 9 kHz–300MHz |
Calibration material |
|
CDG A 3100 |
Mounting plate include 50/150 ohm passage and 50 ohm termination |
CDG 3110 |
100 Ohm resistor (50/150 ohm passage) BNC to BNC |
CDG A 3101 |
Calibration adaptor for CDN M3, M2, M1, L1 – 16A / 32A |
CDG A 3107 |
Calibration adaptor for CDN M5/M4-16/32A / AF5/AF4-MC (AE-port) |
CDG A 3128 |
Calibration adaptor for CDN M5/M4-16/32A / AF5/AF4-MC (EUTport) |
CDG A 3125 |
Calibration adaptor for CDN M3, M2, 63A |
CDG A 3126 |
Calibration adaptor for CDN M3, M2, 100A |
CDG A 3115 |
Calibration adaptor for CDN M5, M4, 63A |
CDG A 3116 |
Calibration adaptor for CDN M5, M4, 100A |
CDG A 3102 |
Calibration adaptor for CDN AF 2 |
CDG A 3101 |
Calibration adaptor for CDN AF 2-MC |
CDG A 3108 |
Calibration adaptor for CDN AF 3 |
CDG A 3101 |
Calibration adaptor for CDN AF 3-MC |
CDG A 3108 |
Calibration adaptor for CDN AF 4 |
CDG A 3107 |
Calibration adaptor for CDN AF 5/AF4-MC (AE-port) |
CDG A 3128 |
Calibration adaptor for CDN AF 5/AF4-MC (EUT port) |
CDG A 3110 |
Calibration adaptor for CDN AF 8 |
CDG A 3114 |
Calibration adaptor for CDN AF 8-MC |
CDG A 3143 |
Calibration adaptor for CDN AF 12-SUBD |
CDG A 3103 |
Calibration adaptor for CDN S 1 |
CDG A 3104 |
Calibration adaptor for CDN S 2 |
CDG A 3130 |
Calibration adaptor for CDN S 4 |
CDG A 3129 |
Calibration adaptor for CDN S 8 |
CDG A 3105 |
Calibration adaptor for CDN S 9 |
CDG A 3113 |
Calibration adaptor for CDN S 15 |
CDG A 3106 |
Calibration adaptor for CDN S 25 |
CDG A 3144 |
Calibration adaptor for CDN S K75-BNC |
CDG A 3111 |
Calibration adaptor for CDN T2 |
CDG A 3112 |
Calibration adaptor for CDN T4 |
CDG A 3109 |
Calibration adaptor for CDN T8 |
CDG A 3117 |
Calibration adaptor for CDN RJ 45 S |
CDG A 3118 |
Calibration adaptor for CDN RJ 45 |
CDG A 3120 |
Calibration adaptor for CDN RJ 11 |
CDG A 3121 |
Calibration adaptor for CDN USB-C (also USB 3.0C) |
CDG A 3122 |
Calibration adaptor for CDN USB-P (also USB 3.0P) |
CDG A 3123 |
Calibration adaptor for CDN HDMI |
CDG A 3127 |
Calibration adaptor for CDN Firewire |
CDG A 3131 |
Calibration adaptor for CDN CAN-BUS, 9-pol SUB-D male and CDN AF 8-SUBD_10 |
Coupling clamps |
|
CDN DCL-20 |
Decoupling clamp for immunity, acc. IEC 61000-4-6, 100 kHz – 1000 MHz, cable diameter max. 20mm. |
CDN EMCL-20 |
EM clamp acc. to /EC/EN 61000-4-6 incl. calibration kit and factory calibration, traceable, cable diameter max. 20 mm |
CDN EMCL-35 |
EM clamp acc. to /EC/EN 61000-4-6 incl. calibration kit and factory calibration, traceable, cable diameter max. 35 mm |
CDN-EMCL-NW_10 |
Matching network 10 kHz – 150 kHz, for using EMCL 20 from 10 kHz to 150 kHz |
KAL SET EMCL |
Calibration set for EMCL, acc. IEC 61000-4-6, Ed. 4.0, 2014 |
IEC / EN 61000 – 4 – 8 / EN 55103 / MIL STD / ISO DC – 250 kHz |
|
MGA 1033 |
Magnetic field analyzer and generator acc. to EN 55103 + IEC 6100-4-8 + MIL-STD-461 E/F, DC-250 kHz, Amplifier 50V / 16A |
MGA 1034_16-SYS |
Complete Test-System for Magnetic field tests acc. ISO 11452-8, MIL-STD-461 E/F and other – incl. compensation board and Triax Coil MGA_HCST_50-28 for magnetic fields until 1000 A/m at 1000 Hz, DC – 250 kHz, Amplifier 50V / 16A |
MGA_RLS 133 |
Radiating / Loop sensor 133 mm acc. to EN 55103-2, incl. 3m cable |
MGA_RL 120 |
Radiating loop 120 mm acc. to MIL-STD-461E / RS101, 3m cable |
MGA_BC-500 |
Radiating loop 50 cm, acc. to EN 55103-2, item A 3.1 |
MGA_LS 040 |
Loop sensor 40 mm acc. to MIL-STD-461E / RE101, incl. 3m cable |
MGA_LS 133 |
Loop sensor 133 mm acc. to MIL-STD-461E / RE101, 3m cable |
MGA_B1 |
Test adapter acc. to EN 55103-2, Fig. B1 |
MGA_B2 |
Calibration network acc. to EN 55103-2, Fig. B2 |
MGA_B4 |
Current transducer acc. to EN 55103-2, Fig. B4 |
MGA_HCS_100-60 |
Helmholtz coil 1-axis (50 kHz) 1,00×1,00m, distance 0,60m |
MGA_HCS_125-75 |
Helmholtz coil 1-axis (50 kHz) 1,25×1,25m, distance 0,75m |
MGA_HCST_50-28 |
Helmholtz coil 3-axis (50 kHz) 0,5 x 0,5m, distance 0,28m |
MGA_HCS_50-28 |
Helmholtz coil 1-axis (50 kHz) 0,5 x 0,5m, distance 0,28m |
MGA_CT-50A |
Coupling transformer acc. MIL-STD-461 CS 101 |
MGA_ISS-19 |
Coupling transformer for tests acc. DO160, Sec. 19 (19.3.1; 19.3.2; 19.3.3), in combination with MGA 1033 |
MGA_SO_CE101 |
Software plug-in MIL-STD-461E / CE101 |
MGA_SO_CS101 |
Software plug-in MIL-STD-461E / CS101 |
MGA_SO_CS109 |
Software plug-in MIL-STD-461E / CS109 |
MGA_SO_4-16 |
Software plug-in EN 61000-4-16 |
IEC / EN 61000 – 4 – 16 Immunity DC – 150 kHz |
|
PGA 1240-5 |
Power Generator DC – 300 kHz; +/-50V; +/-5A, also for the continuous disturbances acc. IEC 61000-4-16. |
PGA 1240-16 |
Power Generator DC – 300 kHz; +/-50V; +/-16 A |
PGA 1240-PSG 300 |
Option “External voltage-source”, input for phase-triggering of an external voltage-source, 50 ohm output, for the short-term tests up to 300V. Option instead of PGA 1330. |
PGA 1330 |
Immunity generator for short-term tests up to 300 V, with 50 ohm serial resistor to the output |
IT – 06 |
Isolation transformer 6 A |
IT – 16 |
Isolation transformer 16 A |
CN M2-AC-32 |
Coupling network for 2 lines 250 VAC, 15 Hz – 150 kHz |
CN M2-DC-32 |
Coupling network for 2 lines 250 VDC |
CN M3-AC-32 |
Coupling network for 3 lines 250 VAC, 15 Hz – 150 kHz |
CN M3-DC-32 |
Coupling network for 3 lines 250 VDC |
CN M4-AC-32 |
Coupling network for 4 lines 250 VAC, 15 Hz – 150 kHz |
CN M5-AC-32 |
Coupling network for 5 lines 250 VAC, 15 Hz – 150 kHz |
CN 1240-32 |
Coupling network switchable M2, M3, M4, M5, 32A, 250 V AC+DC, 15 Hz – 150 kHz |
CN 1240-125 |
Coupling network switchable M2, M3, M4, M5, 125A, 250 V AC+DC, 15 Hz – 150 kHz |
CN M2+M3-32-HV |
CN for 2 and 3 lines, 32A, 520 VAC / 620 VDC, Housing 4 HE |
CN AF 2 |
CN for 2 unsymmetrical, unshielded lines, DC, 15 Hz – 150 kHz |
CN AF 4 |
CN for 4 unsymmetrical, unshielded lines, DC, 15 Hz – 150 kHz |
CN AF 4 |
CN for 4 unsymmetrical, unshielded lines, DC, 15 Hz – 150 kHz with 4mm MC banana plugs |
CN AF 8 |
CN for 8 unsymmetrical, unshielded lines, DC, 15 Hz – 150 kHz |
CN T 2 |
CN for 2 symmetrical, shielded data lines, DC, 15 Hz – 150 kHz |
CN T 4 |
CN for 4 symmetrical, shielded data lines, DC, 15 Hz – 150 kHz |
CN T 8 |
CN for 8 symmetrical, shielded data lines, DC, 15 Hz – 150 kHz |
CN RJ 45 |
CN for unsymmetrical, unshielded RJ45, DC, 15 Hz – 150 kHz |
CN ITU-T |
CN acc. ITU – Fig.1/K 54, for Telecom lines |
IEC / EN 61000 – 4 – 11 and – 4 – 29 Voltage interruption and Voltage dips |
|
VIS 1700_1 |
Voltage interruption simulator according to IEC 61000-4-11, AC and DC ramp function, includes factory calibration VIS 1700_1 |
VIS 740 |
Step transformer 16,0 A for voltage dips, AC using only, 0%, 40%, 70%, 80% – necessary to reach the requirement acc. IEC 61000-4-11 (should also quote KAL VIS 740) |
KAL VIS 740 |
Additional cost for factory calibration of the step transformer. Before delivery of a new VIS 740, if a customer orders the VIS 1700_1 and VIS 740 |
RF – Power Amplifier |
|
PA 1020-25-250 |
RF broadband power amplifier, 25 W, 100 kHz – 250 MHz |
PA 1020-75-300 |
RF broadband power amplifier, 75 W, 100 kHz – 300 MHz |
PA 1020-75-400 |
RF broadband power amplifier, 75 W, 100 kHz – 400 MHz |
PA 1020-75-250 |
RF broadband power amplifier, 75 W, 10 kHz – 250 MHz |
PA 1020-180-400 |
RF broadband power amplifier, 180 W, 1 MHz – 400 MHz |
FNN Chapter 3.7.1 Rules (Electricity Meters) |
|
PG01-2000 |
Pulse generator 0,1μs/2000μs, 10 kV acc. FNN rules |
IEEE 644 |
|
CAL 1250 |
Generator of magnetic fields with 3 channel generator / amplifier for calibration 50 / 60 Hz. |
Additions |
|
EMV-SOFT |
Control software (MS-Windows?) for Schloeder EMC generators (Burst, Surge, Voltage interruption, 3-phase coupling networks) |