LAPLACE INSTRUMENTS PRODUCT LINE
Products by EMC Categories
Emissions
• Antennas
• EMC Emission Analyzers
• LISN
• Near Field Probes
• Pre-selector
• Reference Sources
• RF Sensors/Probes
• Test Cells
• Test Chambers
• Voltage Probe (PLIP)
Harmonic and Flicker
• AC2000A Harmonics & Flicker Analyzer
• AC1000 Clean Power Source
Immunity
• CDN’s
• Dips and Interrupts
• EFT & Burst
• ESD
• Power Amplifiers
• Sensors/Probes
• Surge
• Synthesizers
• Test Cells
• Test Chambers
Mains Filters
Product Software
RF Meters and Sensors
Systems
• Conducted Emissions
• Conducted RF immunity IEC1000-4-6
• Harmonic and Flicker
• Luminaire Test (EN55015)
• Non-RF Immunity IEC61000-4-4 IEC61000-4-5 IEC61000-4-11
• RF Emissions (CDN)
• RF Emissions (Cell/Chamber)
• RF Emissions (OATS)
• RF Immunity (Cell/Chamber) IEC61000-4-3
• Standards
• Sale! Radiated Emission Test System – Reduced!
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
LAPLACE REFERENCE SOURCES
-
Reference sources are compact signal sources that facilitate the calibration of EMC test equipment.
There are 2 types… conducted and radiated……..
The Conducted source (CRS+) is simply plugged directly into a LISN or used with a voltage probe and will check the calibration of the complete measurement system.
The Radiated source (ERS) will check both the site and the measurement equipment. This is particularly important as the greatest source of measurement uncertainty is invariably the site.All references sources are supplied complete with calibration data which for both the CRS+ and the ERS are traceable to NPL (UK)
Key points:
-
RF output: From detachable antenna
-
RF signal: Continuous, steady state,
narrow band, harmonic series. -
Amplitude stability: 0.5dB (short term)
-
Drift over time: 1dB/annum
-
Harmonic spacing 2MHz
-
Frequency range: 30MHz—1GHz
-
Frequency stability: 80ppm
RF level at 3m 50—73 dBuV/m
-
Power: Internal battery (LiMH)
-
Running time: 6 hours
CRS + CONDUCTED REFERENCE SOURCE
CRS+ Front View CRS+ Rear ViewKey points:
-
• Frequency range 15KHz—30MHz
-
• Frequency stability Crystal source 80ppm
-
• Signal type Harmonic series (Narrow band)
-
• Output level 37dBuV—49dBuV (see reverse)
-
• Output channel Push-button selection of L1 or L2
-
• Calibration Individual UKAS traceable
-
• Indication L1 or L2 active
-
• Frequency spacing 10KHZ
-
• Output connection Adapter cable to UK, US or Schuko
-
• Low voltage detection Auto shut down
ASSOCIATED DOWNLOADS
User manual – CRS+ – User manual for the Conducted Reference Source
Conducted reference source – Data sheet
Laplace Instruments Demonstrating the CRS+
Related Products
SA3000 3GHz EMC emissions Analyzer – High performance, PC controlled, 3GHz EMC analyzer with powerful Windows software application.
Antennas for EMC testing – Antennas are normally required for the measurement of radiated emissions. Laplace offers a wide range of antennas to suit the various requirements. These include standard broadband antennas, miniature antennas and Large Loop Antennas
-
-