LAPLACE INSTRUMENTS PRODUCT LINE
Products by EMC Categories
Emissions
• Antennas
• EMC Emission Analyzers
• LISN
• Near Field Probes
• Pre-selector
• Reference Sources
• RF Sensors/Probes
• Test Cells
• Test Chambers
• Voltage Probe (PLIP)
Harmonic and Flicker
• AC2000A Harmonics & Flicker Analyzer
• AC1000 Clean Power Source
Immunity
• CDN’s
• Dips and Interrupts
• EFT & Burst
• ESD
• Power Amplifiers
• Sensors/Probes
• Surge
• Synthesizers
• Test Cells
• Test Chambers
Mains Filters
Product Software
RF Meters and Sensors
Systems
• Conducted Emissions
• Conducted RF immunity IEC1000-4-6
• Harmonic and Flicker
• Luminaire Test (EN55015)
• Non-RF Immunity IEC61000-4-4 IEC61000-4-5 IEC61000-4-11
• RF Emissions (CDN)
• RF Emissions (Cell/Chamber)
• RF Emissions (OATS)
• RF Immunity (Cell/Chamber) IEC61000-4-3
• Standards
• Sale! Radiated Emission Test System – Reduced!
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
LAPLACE SYNTHESIZERS FOR IMMUNITY TESTING
The Laplace Synthesizers cover both conducted and radiated RF immunity test requirements. The frequency coverage extends from 100KHz to 230MHz for conducted tests and 30MHz – 6GHz for radiated tests. They are all controlled from the users PC via a USB link, and powerful Windows software is included to enable the user to control all the parameters of the test, to monitor the test in progress, and to view the results.
Key Points
- • Creates the signal to be applied to the product
- • Controls the intensity of that signal
- • Monitors the condition of the EUT
- • Acts as the interface between a PC and the test
- • Includes PC (Windows) software to enable very simple operation
Software Details
The RFSynth software will run under any version of Windows from XP to Win10. It allows the following parameters to be set:
- • Start frequency
- • Stop frequency
- • Frequency step (%)
- • Stress level (V/m)
- • Modulation (AM and pulsed)
- • Dwell time
- • EUT monitoring (ignore/stop/continue)
- • EUT prompt output
It includes facilities to load calibration data for the test cell, field probe or CDN as appropriate.
Outputs include:
- • Display of target and actual stress level vs. frequency
- • EUT monitor
- • System status
- • Hard copy via Windows printers
- • Results file storage to disk and subsequent retrieval
Product Specification
Parameter |
|||
Start frequency |
100KHz |
80MHz |
80MHz |
End frequency |
300MHz |
3GHz |
6GHz |
Control feedback |
RF (from CDN Cal. adapter) |
DC from LaplaCell |
|
Level control mode |
Pre-calibrate scan (conventional mode) |
Pre-calibrate scan or closed |
Common to all synthesizers:
Frequency step | 0.1% to 5% of current value | |
Output Level | -60dBm to 0dBm (carrier signal) | |
Output level Indication Feedback level indication |
Bar graph display | |
THD (worst case) | 10% | |
Modulation | 1KHz sine, 80% AM modulation200Hz, 10Hz & 1Hz pulsed. 100% level | |
Control Mode | Open loop (Pre-scanned) or closed loop. (Software selectable) | |
EUT status | Volt free contact relay input | |
Fault modes | Stop, pause, continue | |
EUT prompt | 4 pole c/o volt free contacts | |
Modes | Pulsed, Continuous, off |
ASSOCIATED DOWNLOADS
Laplace Instruments RF Synthesizers RF3000 and RF6000 Data Sheet
Laplace Instruments RF Synthesizer RF3000 Users Manual
RF3000 software – PC software for radiated RF immunity testing
RF1000 (RS232 only) – Application software for the serial (RS232) port version
Data Sheet – RFIC Test system for IEC61000-4-6
RFIC46 system user manual – Operators manual for IEC61000-4-6 test system
RFIC-4-6 application software – Self installing software for RFIC system
Data Sheet – High Current, Advanced CDN for 3 phase up to 100A