EnglishPortugueseSpanish

Request a Quote / Contact Us!

    Manufacturer

    Part Number or Numbers

    LAPLACE RADIATED EMISSION TEST SYSTEM - SALE!

    Reliant EMC has an evaluation Radiate Emission Test System from Laplace Instruments for sale at $15,000, this is 36% off of list price!
    All of the components are new, except for the SA1000, which is refurbished.

    This Radiated Emission Test System is in Stock and ready to ship!
    Please see complete details of the Test System below.

    Product Part #

    Laplace Instruments Lts.
    Product Descriptions

    ERS

    Emissions Reference Source

    RF200

    EMC Log Periodic Antenna with Tripod

    RF700

    30MHz High Pass filter

    SA1000

    1GHz Spectrum Analyzer

    SA1020

    1GHz RF Pre-Amplifier

    This System can be upgraded to include Conductive Emission Testing by adding the following items:

     UPGRADE TO CONDUCTIVE EMISSION TESTING:

    – 16 Amp Line Impedance Stabilization Network – LISN16A1P
    – FM Band Filter – RF600
    – Pre-Selector – RF800

     EVALUATION RADIATED EMISSION TEST SYSTEM COMPONENTS

    – SA1000 Spectrum Analyzer 9kHz – 1 GHz
    – EMC Engineering Software
    – ERS – Emission Reference Source
    – SA1020 Pre Amplifier

    – RF200 Antenna Log Periodic 30 – 1000Mhz
    – Tripod

    – RF700 High Pass Filter
    – AFN515FG Filter for conducted and radiated emissions

    SA1000 1GHZ RF SPECTRUM ANALYZER:

    The ideal tool for PC based EMC emissions measurement and general RF applications.

    KEY POINTS

    • Powerful RF Spectrum analyses with Windows interface

    • 10KHz to 1.1GHz coverage
    • Fully PC controlled
    • EMC compliance tests to EN standards
    • True average and quasi-peak measurements
    • Powerful PC based software with Test Director mode for assisted testing
    • Unique single frequency mode for non-steady emissions

    EMC ENGINEERING SOFTWARE DETAILS

      The software included with the SA1000 provides all the control and display features that you need.

      These include:

      • · Full control of the frequency band to be scanned.

      • · Control of the detector, RBW, scan rate, scan mode.

      • · Linear or log scaling of the frequency axis

      • · Instant zoom to any point in the spectrum, at full resolution.

      • · Single frequency mode for monitoring any specific problem emission.

      • · Selection of input device, including automatic AF or insertion loss correction.

      • · Up to 20 markers, with QP and Ave display of results in near real time.

      • · Selection of standard to be applied, with EU, FCC and As/Nz standards pre-loaded.

      • · Facility to input your own limits and/or input device calibration.

      • · Plotting of results to any Windows printer.

      • · Saving of results to disk, and recall at later date.

         

      Laplace Instrument SA1000
      SA1000 RF Spectrum Analyzer

      SA1000 Data Sheet Laplace Instruments SA1000 1GHz RF Spectrum Analyzer Data Sheet

      EMISSIONS REFERENCE SOURCE (ERS)

      The ERS from Laplace Instruments is a comb generator that radiates RF continuously every 2MHz over the range 30MHz – 1000MHz.
      Each 2MHz peak is precisely measured during the calibration process with the ERS orientated both vertically and horizontally. These measurements are correlated against a 3m OATS such that any fully implemented CISPR16 site, measuring at 3m and using height scanning, will read the same.
      In practice, informal sites and test chambers will produce significant differences due to the presence of reflections and/or lack of height scanning.
      The ERS allows these differences to be quantified and EUT measurements can then be corrected.
      This technique substantially improves the measurement accuracy of radiated emissions on all but the best test sites.

      Key Points
      · Very stable and accurate
      · 30MHz – 1GHz coverage
      · Traceable to NPL (UK)
      · Narrow band peak every 2MHz
      · Horizontal and vertical calibration

      FEATURES

      The ERS helps to eliminate the main cause of uncertainty (error) when measuring radiated emissions. These errors are entirely due to the reflections from any nearby metallic objects or surfaces. Also, the ground reflection is a source of error if not using a metallic ground plane and height scanning. Generally, these reflections will account for errors up to 20dB, far too much for compliance measurements.

       

      By replacing the EUT with the ERS, performing a scan and comparing the results with the calibration data, the errors can be quantified and the results from the EUT adjusted accordingly. This technique generally reduces errors to around 6dB, comparable with test laboratory results.

       

      Laplace Instruments ERS Emission Reference Source
      ERS – Emission Reference Source


      Laplace Instruments ERS Data Sheet Laplace Instruments ERS – Emission Reference Source Data Sheet

      LAPLACE INSTRUMENTS SA 1020 BROADBAND PRE-AMP

      The SA1020 is a Broadband RF amplifier with 20dB gain. Its key features are exceptionally low noise, flat gain characteristics and wide frequency range.

      SA1020 Product Specifications

      SA1020 Broadband RF Pre Amplifiier

      SA1020 Broadband Pre Amplifier

      Laplace Instruments SA1020 BroadBand Pre Amplifier Laplace Instruments SA1020 Broadband Pre Amplifier Data Sheet

      LAPLACE INSTRUMENTS RF700, 30MHZ HIGH PASS FILTER

      RF700, 30MHz high pass filter, which blocks all signals below 30MHz. This is most useful as (in general) there can be high levels of RF noise at these lower frequencies which can cause compression issues in the analyses. Because the radiated emission bands start at 30MHz, attenuating these lower frequencies improves performance without affecting any measurements.

      RF700 from Laplace Instruments

      RF700 High Pass Filter

       

      Laplace Instruments SA1020 BroadBand Pre Amplifier Laplace Instruments RF700 High Pass Filter Data Sheet

      LAPLACE INSTRUMENTS RF200 ANTENNA

      High performance EMC antennas to cover the range 30MHz – 4GHz

      COMPREHENSIVE
      The RF200 is designed to cover the whole range from 30MHz to 1GH
      in one sweep. No need to change antenna part way through the scan.

      CALIBRATION
      The RF2xx design is fully calibrated on the 10m OATS site at NPL. This data is included with each antenna. For emissions measurement, the RF200 is used in conjunction with the SA1020 per-amplifier. This ‘head’ amplifier improves sensitivity and decouples the output lead from the antenna, avoiding
      spurious cable influences on the results.
      > One antenna covers complete band C and D
      (30MHz – GHz)
      > Compact antenna for 700MHz – 4GHz
      > Supplied with calibration data
      > Excellent sensitivity, ideal for EMC testing
      > Vertical and horizontal polarization

      COMPREHENSIVE
      The RF200 is designed to cover the whole range from 30MHz to 1GH
      in one sweep. No need to change antenna part way through the scan.

       

      CALIBRATION
      The RF2xx design is fully calibrated on the 10m OATS site at NPL. This data is included with each antenna. For emissions measurement, the RF200 is used in conjunction with the SA1020 per-amplifier. This ‘head’ amplifier improves sensitivity and decouples the output lead from the antenna, avoiding spurious cable influences on the results.

       

      The RFxx range are specifically designed for general use as EMC emissions measurement antennas. They combine excellent broadband characteristics with high sensitivity and sturdy
      construction.
      Although primarily used with the Laplace range of analyzers and receivers, they can be used with any other receiver and are supplied with full calibration data so that antenna factors can be entered into
      any third party system.

       

      In order to achieve optimum performance stability, the RF200 is designed to work with the SA1020 pre-amplifier, located at the head of the support.
      This improves sensitivity and ensures that cable configuration does not affect results.
      The RF200 is supplied complete with rigid stand and the RF230 is complete with an all plastic miniature tripod.

       

      RF200 Antenna from Laplace Instruments

      RF200 Antenna

       

      Laplace Instruments SA1020 BroadBand Pre Amplifier Laplace Instruments RF200 Broadband Antenna Data Sheet