SCHWARZBECK PRODUCTS
• Accessories
• Antennas
• Antenna Adapter, Masts, Telescopes and Wheels
• Attenuators And Pulse Limiters
• Baluns
• Blocking Filters
• CDN´s
• CDNE
• Clamps: Abosorbing, Injection And Capacite Coupling Clamps
• Coaxial Cables
• Comb Generators / Reference Radiators
• Dummy Lamps
• Electromagnet
• Field Meters
• Helmhotz Coils / Radiating Loops
• LISN Line Impedance Stabilization Networks / AMN Artificial Mains Network
• BAN Broadband Artificial Networks Acc. To ISO 11452/7 Or DC-10614
• MagTest System
• Near Field Probes
• PLC – Devices Acc. To En 50561-1
• Preamplifiers
• Pulse Generators
• Striplines / TEM – Cells
• Spectrum Generator
• Used Equipment
• Van Der Hoofden Test Head
• Voltage Probes
SCHWARZBECK Company
SCHWARZBECK Data Sheets
SCHWARZBECK Product List
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
Accesories
Schwarzbeck Accessories
• ACS 110 – Traveler Charger for Probes and Antennas
• ACT 461G – Audio Coupling Transformer
• BN 1701 – Buffer Network
• BD 9501 – IEEE-488 Bus-Feed Through
• CA 9607 – Universal Calibration Adapter for Current Clamps
• CA 9608 – Universal Calibration Adapter
• CAP 10 – 10 µF Capacitor for NNBM 8124. For airborne equipment
• CAP 10 8226-2 – 10 μF capacitor for NNBL 8226-2 LISN and for military equipment
• CCA – Product Transport Cases
• CCC 9224 – Capacitive Coupling Clamp
• CCC 9225 – Capactive Coupling Plate
• CISPR 17 Equipment – Transformers
• CVP 9222 C – High Impedance Capacitive Voltage Probe
• CVP 9222 – High Impedance Capacitive Voltage Probe
• HPF 150 k – High Pass Filter
• KU 9608 – Coaxial and Line Switch
• SW 9602 – Current Transformer
• SW 9603 – Current Transformer
• SW 9605 – Current Transformer
• SW 9606 – Current Injection Clamp
• TF 130-150 – Test Fixture for Ford RI 130/ 150
ACS 110 Traveler Charger for Probes and Antennas ![]()
· Charger for Probes and Antennas with built in with built in NiMH-batteries

ACT 461G – Audio Coupling Transformer
Audio coupling transformer for conducted audio frequency susceptibility tests as required by MIL STD 461G and other standards.
Frequency range 10 Hz – 250 kHz, 200 W, turn ratio 2:1.
Output and input: wing terminals.
· Buffer network (CISPR 17)
· Frequency range: 100 kHz – 30 MHz
· max. 32 A
BD 9501 IEEE-488 Bus-Feed Through ![]()
· IEEE-488 Bus-Feed through for flange mounting
(shielded rooms) (other feed throughs on request)
CA 9607 Universal Calibration Adapter for Current Clamps ![]()
· Universal calibration adapter for current clamps
· test jig for ferrites
CA 9608 Universal Calibration Adapter ![]()
· Universal calibration adapter for e.g. the following current clamps:
· R&S ESV-Z1, Prodyn, IT-050-1
· length and height settable
CAP 10 10 µF Capacitor for NNBM 8124 ![]()

· 10 µF Capacitor for NNBM 8124
· 500 V (AC)
· 400 Hz
· DEF STAN 59, DO 160
Schwarzbeck CAP 10 10uF Capacitor for NNBM LISN Data Sheet
CAP 10 8226-2 10 μF capacitor for NNBL 8226-2 LISN ![]()
To be compliant to the standard MIL 461F (method CS 101-4 and CS 106-3) a 10 μF capacitor like the CAP 10 8226-2 has to be connected to the mains connectors of the LISN.
Schwarzbeck CAP 10 8226 2 10uF Capacitor for NNBL 88226 2 LISN Data Sheet

· CCA product transport cases keep your equipment safe, at any time. During transport or for safe storage
· Individual for your product
· A combination of products in one case are possible
· More information about CCA and some examples are
shown in the Data Sheet

· Transformers
· fixtures and adapters to measure filters
· ferrites and other passive components.
· Detailed product list and data sheets on request.
The current sensor CP 9610 can measure up to 40 A in a frequency range from DC – 1 MHz. It is galvanically isolated and can withstand a maximum voltage of 210 VPK / VDC. The internal resistance of the conductive path is less than 3 mΩ, providing low power loss. The hall transducer is temperature compensated and allows high accuracy over temperature.
| Frequency Range: | DC – 1 MHz |
| Output Connector: | BNC (1 MΩ) |
| Current Sensing Range: | -40 A – +40 A |
| Nominal conversion factor: | 50 mV/A |
| Internal Conductor Resistance: | < 3 mΩ |
| Typical Output Error: | ±3 % |
| Dimension: | 105 x 44 x 115 mm |
| Typical Operation Time: | 24 h |
| EuT Connector: | Wing terminals |
| Power Supply: | 3.7 V, 2.6 Ah Lithium Ion |
| Weight: | 430 g |
Schwarzbeck CP 9610 – Current Sensor Data Sheet
CVP 9222 High Impedance Capacitive Voltage Probe ![]()

· High Impedance Capacitive Voltage Probe according to to CISPR 22
· EN 55022 C 1.3
· Frequency range: 9 kHz – 100 MHz
Options:
· Option ACS 110:Charger ACS 110 for CVP 9222
· Option CAL 9222: Calibration Adapter for CVP 9222
CVP 9222 C High Impedance Capacitive Voltage Probe ![]()
High Impedance Capacitive Voltage Probe acc. to
CISPR 22
EN 55022 C 1.3
Frequency range: 9 kHz – 100 MHz
Options:
· Option ACS 110: Charger ACS 110 for CVP 9222, CVP 9222 B and CVP 9222 C
· Option CAL 9222 B: Calibration Adapter for CVP 9222, CVP 9222 B and CVP 9222 C
Schwarzbeck CVP 9222 C High Impedance Capacitive Voltage Probe Data Sheet

· High Pass Filter
· 35 – 1000 MHz
· Insertion loss at 27.12 MHz type 100 dB
The HPF is a passive LC-Filter with female N-connectors in shielded metal housing with very steep slope according to CISPR 16-1-1.
The main application is the elimination of noise below 150 kHz for conducted interference voltage measurements.
Particular features are high pulse load capacity and dielectric strength.
Specifications
| Frequency Range | 9 kHz – 30 MHz |
| Fundamental frequency: |
150 kHz |
| Nominal impedance: |
50 Ω |
| Continuous power: |
100 W |
| Passband loss: |
< 1.5 dB |
| Passband VSWR: |
< 2 |
| Stopband loss: |
>50 dB @ ≤ 130 kHz |
| Housing material: |
Aluminium |
| Housing dimensions: (with connector) |
50 x 105 x 240 mm |
| Weight: | 860 g |
| Connector: |
2 x N female |
Schwarzbeck HPF 150 k High Pass Filter Data Sheet
KU 9608 Coaxial and Line Switch ![]()
· Coaxial and line switch for measurement of the attenuation of fluorescent lighting fittings
· Current Transformer
· shielded
· 0.01 – 200 MHz
· Transfer Impedance: 1 Ohm for wires up to 6.5 mm
· Current Transformer
· shielded
· 9 kHz – 150 MHz
· Transfer Impedance: 1 Ohm for wires up to 14 mm
TF 130-150 Test Fixture for Ford RI 130/ 150 ![]()


· Test Fixture for Ford RI 130/ 150 Per EMC-CS-2009