SCHWARZBECK PRODUCTS
• Accessories
• Antennas
• Antenna Adapter, Masts, Telescopes and Wheels
• Attenuators And Pulse Limiters
• Baluns
• Blocking Filters
• CDN´s
• CDNE
• Clamps: Abosorbing, Injection And Capacite Coupling Clamps
• Coaxial Cables
• Comb Generators / Reference Radiators
• Dummy Lamps
• Electromagnet
• Field Meters
• Helmhotz Coils / Radiating Loops
• LISN Line Impedance Stabilization Networks / AMN Artificial Mains Network
• BAN Broadband Artificial Networks Acc. To ISO 11452/7 Or DC-10614
• MagTest System
• Near Field Probes
• PLC – Devices Acc. To En 50561-1
• Preamplifiers
• Pulse Generators
• Striplines / TEM – Cells
• Spectrum Generator
• Used Equipment
• Van Der Hoofden Test Head
• Voltage Probes
SCHWARZBECK Company
SCHWARZBECK Data Sheets
SCHWARZBECK Product List
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
Voltage Probes
• TK 9261 Active Voltage Probe 0.1-100MHz
• TK 9421 High Power Voltage Probe
• TK 9422 High Power Voltage Probe
In addition to EMI measurement with LISNs (Line Impedance Stabilization Networks, Artificial Mains Networks), Probes are used for Terminal or Line voltage measurement.
LISNs are required to feed the Equipment under Test (EUT) with mains power, to reduce external line interference, to offer the EUT a standardized impedance and to route the extracted r.-f. voltage to the EMI receiver.
Probes are used for terminal voltage measurement, also on cables, output sockets, PCB traces. In many cases high input impedance and low capacitance is required for this purpose.
Active Probes may not be used for general Interference measurement, as pulses could by far exceed the linear voltage range. This not only causes limiting and distortion effects but also inter-modulation that changes the frequency distribution of spectral components.
These resistive dividing probes are perfectly linear and free of these effects.
By the use of an AC and pulse-compatible input blocking capacitor (that is also free of partial discharge effects), EMI measurement is also possible on AC power lines up to 250 V ac or DC sources up to 500 V.
High-Voltage Probes up to 10 kV (20 kV) DC or 2 kV AC with 1500 Ω input || 4 pF input capacity are available as TK 9420.
For the max. power line voltage of 250 V ac two probes are available with input resistances of 1.5 kΩ, and 2.5 kΩ with the model numbers TK 9420, and TK 9417.
TK 9261 Active Voltage Probe 0.1-100MHz
The TK 9261 is an active high-impedance RF voltage probe equipped with an internal impedance transformer which allows using it with 50 Ω measurement devices (such as spectrum and network analyzers or test receivers).
Nominal frequency range (±1 dB): |
100 kHz – 100 MHz |
Useable frequency range:(±3 dB): |
50 kHz – 700 MHz |
Input damping resistance: |
>100 kΩ |
Input capacitance: |
1.8 pF typ. |
Output impedance: |
50 Ω |
Gain: |
0 dB |
Maximum output level: |
1.4 V peak |
Maximum input d.c. level: |
500 V |
Maximum input a.c. level: |
10 Vp-p |
Output: |
N-plug |
According to: |
Renault 36-00-808 |
Power supply: |
+12…15 V |
DC-connector: |
5.5 mm / 2.5 mm |
Ambient temperature: |
-10° … +60°C |
Weight: |
300 g |
TK 9261 Active Voltage Probe 0.1-100MHz Data Sheet
· HF-Probe
· 2.5 kOhm
Data sheet TK9417
· High-Voltage-Probe
· 1.5 kOhm
· 4 pF
· 9 kHz – 30 MHz
· RF < 30 V
· Plug-In divider 1.5 kOhm for TK 9420 probe for determination of disturbance source impedance
TK 9421 High Power Voltage Probe
· High Power Voltage Probe
· 1.5 kOhm
· 4 pF
· 150 kHz – 30 MHz
· RF < 100 V
TK 9422 High Power Voltage Probe
· High Power Voltage Probe
· 5 kOhm
· 4 pF
· (9) 150 kHz – 30 MHz
· RF < 100 V