SCHWARZBECK PRODUCTS
• Accessories
• Antennas
• Antenna Adapter, Masts, Telescopes and Wheels
• Attenuators And Pulse Limiters
• Baluns
• Blocking Filters
• CDN´s
• CDNE
• Clamps: Abosorbing, Injection And Capacite Coupling Clamps
• Coaxial Cables
• Comb Generators / Reference Radiators
• Dummy Lamps
• Electromagnet
• Field Meters
• Helmhotz Coils / Radiating Loops
• LISN Line Impedance Stabilization Networks / AMN Artificial Mains Network
• BAN Broadband Artificial Networks Acc. To ISO 11452/7 Or DC-10614
• MagTest System
• Near Field Probes
• PLC – Devices Acc. To En 50561-1
• Preamplifiers
• Pulse Generators
• Striplines / TEM – Cells
• Spectrum Generator
• Used Equipment
• Van Der Hoofden Test Head
• Voltage Probes
SCHWARZBECK Company
SCHWARZBECK Data Sheets
SCHWARZBECK Product List
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
Clamps: Absorbing, Injection And CCC
• CCC 9224 Capacitive Coupling Clamp
• CCP 9225 Capacitive Coupling Plate
• CMAD 1614 Common Mode Absorption Clamp/Device
• CAL CMAD 1614 – Calibration Fixture for CMAD 1614
• EM 101 + FTC 101 – Replaced by the KEMZ 801AS
• EM 101 Cal KiT – Replaced by the KEMZ 801AS
• EM 101 Current Injection ClamP – Replaced by the KEMZ 801AS
• FT 33X15 Surface Current Blocking Filter
• FTC 101 Surface Current Blocking Filter Clamp
• FTC40X15E Absorbing Clamp
• KEMZ 801 AS EM CLAMP FOR IEC / EN 61000-4-6
• MDS 21 B EMI Absorbing Clamp
• SW 9605 Current Transformer Clamp
• SW 9606 Current Injection Clamp
CCC 9224 Capacitive Coupling Clamp
· Capacitive coupling clamp for transients according to to ISO 7637-3 or DC-10614 B.5.
CCP 9225 Capacitive Coupling Plate
· Capacitive coupling plate
· The main application is to conduct CV-tests (capacitive voltage measurements).
· The capacitive coupling plate CCP 9225 complies to the automotive manufacturer standard MBN 10284-2 2011-04, Annex B.
CMAD 1614 – Common Mode Absorption Clamp/Device
The CMAD 1614 – Common Mode Absorption Device consists of many precision cut ferrite half-toroids, which are embedded in a grey plastic housing. The unique floating toroid bearing ensures a perfect fit of the ferrite surfaces. Two quick-locks at the long side allow opening and closing of the clamp within seconds.
Cable bundles or coaxial cables with a maximum diameter of 26 mm are accepted by the clamp without disassembling connectors or interrupting any circuitry.
The combination of short length and large cable hole diameter offer a broad variety of applications for the CMAD 1614.
Each common mode absorption device comes with an individually measured calibration certificate.
The CMAD 1614 can be used for both, coaxial cables and unshielded cable bundles, in order to suppress unwanted common mode currents (also called braid currents). Since these unwanted common mode currents are very often a reason for poor repeatability of measurements, the new CISPR 16-1-4 standard recommends the use of absorbing clamps.
Frequency Range: | 30 MHz – 200 MHz |
Specified in: | CISPR 16-1-4 |
Usable Frequency Range: | 10 MHz – 1 GHz |
S11 (30 MHz): | 0.6 – 0.75 |
S11 (200 MHz): | 0.4 – 0.55 |
S21: | < 0.25 |
Max. Cable Diameter: | 26 mm |
Housing Material: | PVC |
Housing Dimensions: | 66 x 70 x 414 mm |
Weight: | 3.2 kg |
Schwarzbeck CMAD 1614 – Common Mode Absorption Clamp/Device Data Sheet
CAL CMAD 1614 – Calibration Fixture for CMAD 1614
The CAL CMAD 1614 calibration fixture is used to calibrate / verify the performance of the common mode absorption device CMAD 1614. The fixture consists of an aluminium base plate with two sideplates, adjustable in height and position and each of them equipped with N-connector and inner conductor fixture. A variety of inner conductors with 4 mm diameter is part of the delivery. The calibration fixture was designed for measurements acc. to CISPR 16-1-4 sections 9.5 and 9.6.
Frequency Range: | 30 MHz – 200 MHz |
Specified in: | CISPR 16-1-4 |
Useable Frequency Range: | 10 MHz – 1 GHz |
Material: | Aluminium |
Dimensions: | 113 x 150 x 788 mm |
Weight: | 2.2 kg |
Schwarzbeck CAL CMAD 1614 – Calibration Fixture for CMAD 1614 Data Sheet
EM 101 + FTC 101 – Replaced by the KEMZ 801AS
· System injection clamp EM 101 with braid current blocking clamp FTC 101
· FT14X15 Surface current blocking filter 100 – 1000 MHz
Schwarzbeck FG14x15 Injection and Braid Current Blocking Data Sheet
EM 101 Cal Kit – Replaced by the KEMZ 801AS
· Calibration kit for EM 101
· consisting of 2ea CR 100
· 1 safety lab cable 10 cm
· 1ea cable 80 cm
· both sides banana
EM 101 Current Injection Clamp– Replaced by the KEMZ 801AS
· Current Injection Clamp
· 0.15 – 1000 MHz
· 100 W
· 4kV max.
· max. cable diameter 22mm
Schwarzbeck EM 101 Current Injection Clamp Data Sheet
Schwarzbeck EM 101 Current Injection Clamp Manual
Schwarzbeck EM 101 Current Injection Clamp Data
· FT34X15 Surface current blocking filter 1 – 1000 MHz
· FT 32 Surface current blocking filter 0.01 – 1000 MHz
Schwarzbeck FT 32 Surface Current Blocking Filter Data Sheet
· FTC40X15C Absorbing Clamp 10 – 1000 MHz
· Surface current blocking filter
· 10 – 1000 MHz
Schwarzbeck FG 33X15 Surface Current Blocking Filter Data Sheet
· Surface current blocking filter clamp
· (in combination w. EM 101)
Schwarzbeck FTC 101 Surface Current Blocking Filter Clamp Data Sheet
· Absorbing Clamp
· 1 – 1000 MHz
· CISPR 22
KEMZ 801AS EM CLAMP FOR IEC / EN 61000-4-6
EM Clamp, compliant with IEC 61000-4-6 (incl. edition 4), supplied with adapter set CAL 801A for stress level setting, incl. traceable calibration (certificate according ISO17025)
KEMZ 801AS EM CLAMP FOR IEC / EN 61000-4-6 Data Sheet
· EMI Absorbing Clamp
· 30 – 1000 MHz
· according to CISPR 16 for interference power with silicon coated rolls
Also for shielding measurements on coax. cables
Schwarzbeck MDS 21 B EMI Absorbing Clamp Data Sheet
Schwarzbeck MDS 21 B EMI Absorbing Clamp Features
SW 9605 Current Transformer Clamp
· Current Transformer Clamp
· CISPR 22
· 9 kHz – 80 MHz
· Transfer Impedance: 1 Ohm for wires up to 23 mm
SW 9606 Current injection clamp
· Current injection clamp for RF current injection into harnesses
up to 23 mm diameter
· transducer 18 dB